Sisdoz_m20_cl_İşletme Bakım Klavuzu
Transkript
Sisdoz_m20_cl_İşletme Bakım Klavuzu
M20W CL Instruction Manual 1 2 0.23 ZERO GAIN ppm SET CAL FUN M20 W Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 1 The box contain Measure instrument, instruction manual, mounting accessories, fuse. General features Measure range Functions Resolution Display Accuracy Controls Set-point Outputs Hysteresys Delay time P.W.M. Power supply Consumption Fuse Box Dimensions Weight 0-10.00 ppm Measure, control and regulation of free Chlorine concentration ±0.01 ppm LCD 3 ½ DIGIT ± 1% F.S. Keyboard (5 keys) 2 points ON/OFF 5A to 230vac 4-20mA selectable for recorder or proportional to the setpoint 2 Adjustable for each setpoint Adjustable for each setpoint Selectable on set point 2 in time/pause way 230 Vac 50Hz (optional 110/ 24 Vac) 5W 315 mA delayed Plastic IP65 180x115x75 mm 560 gr. Attention Before to make any operation on the isntruments to verify that the power supply cable isn’t connected Check that the electric system voltage correspond with value on the instrument label Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 2 Dimensions 0.23 1 180 mm 2 ZERO GAIN ppm SET CAL FUN M20 W 115 mm Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 75 mm 3 Electrical connections Power supply To connect the power supply wires to the clamps 1 and 3 (2 ground) and tourn-on the instrument. The display shows the software revision and successfully the instrument go in measure and is ready to follow the normal functions. Description Display Led relays status Led zero calibration 1 2 0.23 GAIN ppm Up – Down keys SET key set-point menu Led gain calibration ZERO M20 W Key calibration starting CAL FUN key menu functions Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 4 Calibration Connect the probe to the instrument and leave to flush water with 0 ppm of chlorine for at least 5 minuts to stabilize the probe. Push CAL key. The red led ZERO flashing and shows the probe zero adjustment. Pushing UP and DOWN keys to adjust the display value since to show 0.00 ppm. Therefore push key CAL to confirm. Flush water with ppm value known (DPD1 colorimetric test). The red led GAIN flashing and shows the probe gain adjustment. Pushing UP and DOWN keys to adjust the display value since to show the value of chlorine concentration. Therefore push key CAL to terminate calibration procedure. If during calibration you don’t push any key for 60 seconds the instrument automatically back in measure condition. Set-Point adjustment Set-point 1 Push SET key, the corresponding green led flashing, the display shows the value previously set (default 1.00 ppm). With UP and DOWN keys adjust the display value since to obtain the desired value. Push key SET to confirm the value and to pass at the hysteresys setting. The display shows the value previously set (default 0.1 ppm), through Up and DOWN keys is possible to modify this parameter by steps of 0.1 ppm. Push SET key to confirm the value and to pass at the delay time setting. The display shows the delay time value (seconds) to active or deactive the set-point (default d00, 0 seconds). Through UP and DOWN keys it’s possible to modify the value since to 99 seconds. Push SET key to confirm the value and pass to the Set-point 2. Set point 2 Finished the set-point 1 setting display shows the set-point 2 value previously set and the green led 2 flashing. Following the same operation about the set-point 1 setting is possible to modify the set-point 2 value, hysteresys and delay time. Push SET key to confirm the value and back to the measure mode. If during the set operations doesen’t push any keys for at least 60 seconds the instrument automatically back in measure mode. Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 5 Functions Through the activation / deactivation of the function is possible to change the statement of the instrument for a best flexibility. Active / Deactive instrument functions Push FUN key, the display shows F1 with the function state (d = Deactived, A = Actived). Pushing UP or DOWN keys is possible to change the function state. To confirm choice push FUN key, if you changed the function state the instruments memorized the choice and back in the measure mode, otherwise it pass to the succesfully function, since to the function F8, therfore back in the measure mode. If during the set operations doesen’t push any keys for at least 60 seconds the instrument automatically back in measure mode. Direct or reverse mode Function Set-point 1 mode: direct F1_d Function Set point 1 mode: reverse F1_A Function Set-point 2 mode: direct F2_d Function Set point 2 mode: reverse F2_A. Normally both the set point are set for a direct mode regulation, therefore the output relay is actived when the measure is lower then the set-point value. To change this condition is necessary to active the F1, about the set-point 1, and active the F2 for the set-point 2. Hysteresys or double threshold Function set point 1 with hysteresys F3_d Function set point 1 with double threshold F3_A Function set point 1 with hysteresys F4_d Function set point 1 with double threshold F4_A Hysteresys function creates a no-operation range around the set-point value. In this area the relay doesn’t change the state (ex.: 0.5H creates a renge of 0.5 ppm). If you active the function F3 (set-point 1) and F4 (set-point 2) both the set-point change the functional mode in double threshold. In this way you create a window around the setpoint value. Example: set-point set on 1.00 ppm and hysteresys on 0.5H, in this way you create a window between 0.50 and 1.50 ppm. Into this range the realy is in off, over this range the relay is in on. Obviously is possible to reverse this condition changing the parameters F1 and F2. This solution is useful if you need to create an alarm window. Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 6 Function F5 unused 4-20mA current output Function Realy on set point 2 ON/OFF activation and 4-20mA output for recorder F6_d Function Relay on set point 2 proportional time/pause and 4-20mA output F6_A proportional to the set point 2 value With F6 deactived (default) the set-point 2 relay work ON/OFF and the 4-20 mA output signal is proportional to the measure range (4 mA = 0 ppm; 20 mA = 10 ppm). When F6 is actived the set-point relay work in proportional time/pause way and the 4-20 mA output signal is proportional to the set-point value. In this way the signal is 4 mA when the measure in on the set-point value. Throgh the F2 function is possible to decide the “direction” of 4-20 mA signal . Function 4-20 mA proportional signal on set point 2 with range regulation of 1.00 F7_d ppm Function 4-20 mA proportional signal on set point 2 with range regulation of 0.50 F7_A ppm With F7 function is possible to decide the range value about the proportional signal on setpoint 2. Function F8 unused Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 7 Troubleshooting Malfunction Possible cause Solution Check the electrical connections Check if the power supply No power supply Display switch off printed on the instrument label is correspondent with local electrical net Internal fuse is breack Change the fuse To be sure, check the The chemical parameter parameter with a portable value is constant instrument or with a Measure on the display is fix colorimetric kit (doesn’t change) Repeat the probe calibration The signal from the probe and if the problem remain doesn’t change change the probe Check the electrical local Electrical disturbs from net. Control the heart electrical local net connection. Measure on the display Check the instrument, change continuously putting the probe into a (measuring jumps) Electrical disturbs into the buffer solution, if the measuring liquid instrument measure correctly eliminate the electrical disturb. Buffer solution are defective Change the buffer solution Isn’t possible to complete the calibration procedure Probe is defective Change the probe Setpoint value is wrong Change setpoint value Change the setpoint The setpoint relay doesn’t function mode, direct or close the contact Setpoint “direction” is wrong reverse, from the menu functions If isn’t possible to back the instrument in a correct functionality following the prevoius indications please contact your local distributor. Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 8 EASY SETTING Set-Point pH Dosing = Chlorine Set-point = 1.00 ppm 1.10 1.00 X5 Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 9 Calibration 0.05 0 ppm 0.00 Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 10 1.05 Example: Chlorine concentration = 1 ppm 1.00 Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 11 Note: Sisdoz Dozlama Sistemleri Üretim ve Pazarlama Ltd. Şti. Bostancı Yolu Cad. Keyap Sitesi A-2 Blok No: 12 Y.Dudullu, Ümraniye, İstanbul Tel: 0216 526 54 70 Faks: 0216 526 54 71 sisdoz@sisdoz.com.tr www.sisdoz.com.tr 12