Automation Devices
Contro Aut ControlIT Automation Devices 0601_PLC.indd b 17-11-2006 9:38:48 ControlIT Automation Devices PLC’s and Operator Panels Contents Scalable PLC AC500 with S500 I/O Devices The AC500 PLC family ................................................................................................. Technical Data - Overview ............................................................................................ AC500 CPUs........................................................................................................... S500 I/O modules ................................................................................................... AC500 system data................................................................................................. Dimensional Drawings .................................................................................................. Ordering Data .............................................................................................................. AC500/S500 ........................................................................................................... Programming package PS501................................................................................. 6/5 6/7 6/7 6/8 6/10 6/11 6/12 6/12 6/15 Small and Compact PLCs AC31 The AC31 PLC family ................................................................................................... Safety PLC AC31-S ...................................................................................................... Technical Data - Overview ........................................................................................... AC31 CPUs............................................................................................................. AC31 I/O modules................................................................................................... AC31 system data................................................................................................... Dimensional Drawings .................................................................................................. Ordering Data ............................................................................................................... Small PLC AC31 series 40..50 ................................................................................ Series 40...50 accessories ...................................................................................... Compact PLC AC31 series 90 ................................................................................ Series 90 accessories and programming pack. 907AC1131.................................... Safety PLC AC31-S................................................................................................. 6/16 6/17 6/18 6/18 6/20 6/22 6/24 6/26 6/26 6/28 6/29 6/31 6/32 PLC’s Overview Operator Panels and PLC families ................................................................................ 6/2 Communication Protocols ............................................................................................ 6/3 Programming................................................................................................................ 6/4 Further Accessories for Control Engineering Ordering Data ............................................................................................................... 6/33 Bus repeaters .......................................................................................................... 6/33 ro t 0601_PLC.indd 1 Displays and Operator Panels Overview ...................................................................................................................... Ordering Data ............................................................................................................... Operator Panels ...................................................................................................... Accessories............................................................................................................. 6/35 6/38 6/38 6/39 6/1 1SDC007200C0202 17-11-2006 9:39:55 Automation Devices Operator Panels and PLC families Operation Text display Graphical display Touch screen Control / communication scalable small compact central + decentral central + decentral decentral AC500/S500 AC31 series 40 .. 50 AC31 series 90 I/O modules PLC family Using these components you will be able to find a proper automation solution for every application: Operator panels: Text display, graphical display or touch screen Scalable PLC AC500: NEW! Simple and consistent expandability, flexible when choosing a field bus. I/O modules S500: For use as centralized expansion of the AC500 PLC and decentralized fieldbus-neutral I/Os. Small PLC AC31 series 40 .. 50: Small but high-performance. Expandable centrally and decentrally. Compact PLC AC31 series 90: For demanding applications. Simple decentral expandability. With 60 I/Os and up to 5 integrated interfaces for open communication. Programming: Acc. to IEC61131-3 (incl. extensive libraries and configurators). For higher safety: Safety-related PLC AC31-S. Power supplies: Linear power supplies and primary-switched power supplies. Logic modules AC010: For small and cost-effective solutions. Available in different versions and for different voltages. 6/2 1SDC007200C0202 0601_PLC.indd 2 17-11-2006 9:39:55 Automation Devices Communication Protocols Overview of communication protocols: Description Ethernet Supports transmission and reception of data using TCP/IP and/or UDP/IP. Further application layers can be implemented by subsequent loading. Simultaneous operation of TCP/IP, UDP/IP and application layer is also assured. The protocols IP, TCP, UDP, ARP, RP, BOOTP and DHCP are supported as a standard feature. Communication with third-party systems via MODBUS/TCP or customer-specific application layers. Star-shaped topology via Ethernet hub or switch. Maximum transfer rate 10 Mbit/s with 10 Base T or 100 Mbit/s with Fast-Ethernet. Transmission media: Twisted-pair cable with RJ45 connector. Maximum cable length: 100 m at a transfer rate of 100 Mbit/s. Profibus DP Provides master-slave communication in the field. Connection to Profibus automation systems and intelligent preprocessors like drives, operator panels and sensors. Maximum length of the network (RS 485): 1200 m at 9.6 kbit/s. Maximum perm. number of stations: 32 stations per network (master and slave stations), 126 stations when using repeaters. Supported transfer rates: 9.6 kbit/s up to 12 Mbit/s. System cable: Shielded twisted-pair cable or fiber-optic cable, transmission standard EIA RS485. Modbus® RTU Open master/slave protocol. Standard protocol implemented in AC500 and AC31. Pointto-point topology via RS232 or multi-point topology via RS485. With RS232, a maximum of 1 master and 1 slave is possible, RS485 allows the operation of 1 master and a maximum of 31 slaves. The maximum cable length is 15 m with RS232 and 1.2 km with RS485. Data transmission can be performed with a maximum of 187.5 kbit/s (AC500). Different transmission media are possible. One widely used option is the RS485 bus physics, a shielded twisted-pair cable with terminating resistors. CANopen and DeviceNet For transmission of data between control systems, decentralized I/O modules, drives, valves, etc. DeviceNet and CANopen both utilize the physical structure and the data transport mechanisms of CAN (Controller Area Network). The difference lies in the transmission protocols. Cable lengths and transfer rates: from 40 m at 1 Mbit/s to 1000 m at 20 kbit/s. CANopen: The bus operates on the master/slave principle with one master and up to 127 slaves. A shielded twisted-pair cable is used according to ISO 11898. DeviceNet: The bus operates on the multi-master and/or the master/slave principle, with up to 64 bus subscribers. Two types of shielded twisted-pair cables are used: trunk cable for the main line and drop cable for the branch line. ARCNET ARCNET is the basis for cost-efficient and fast connection of a process visualization and other systems by networking. Data transfer rate: 2.5 Mbit/s. Collision free data transfer due to token bus with automatic login and logoff of the bus subscribers. Automatic reconfiguration of the network when a station activates or deactivates. Up to 255 masters are possible on the same network. Overall network length: 300 m max., up to 6 km with repeaters. Variable network topology: Bus, tree or star topologies or mixtures of these. Variable transmission media: Mixed use of coaxial cables, twisted-pair cables and/or fiber-optic cables is possible. CS31 Bus for an easy connection of CPUs and I/O devices. Data transfer rate: 187.5 kbit/s. Topology: Multi-point line, RS485, without branch lines. Maximum number of devices: 1 master and 31 slaves. Maximum cable length: 500 m or 2000 m with repeater. With repeaters you can also achieve bus redundancy. Transfer rate: 187.5 KBaud. The slaves usually are decentralized I/O modules with an integrated CS31 bus interface. Data transfer is performed at 187.5 kbit/s. For the transmission medium primarily a shielded twisted-pair cable with termination resistors is used. Other transmission media: fiber-optic cables via converter (glass fibers max. 3 km, plastic fibers max. 100 m), contact lines, slip rings (max. bus length 50 m) and data photocells. AC31 Safety Fieldbus For certified transmission of safety signals between safety-related controllers and the safety-related I/O devices (AC31-S only). Mixing of safety-related signals and operation signals is possible. Transfer rate: 187.5 kbit/s. PLC’s Communication processor / module 6/3 1SDC007200C0202 0601_PLC.indd 3 17-11-2006 9:42:22 Automation Devices Programming Programming packages PS501 and AC1131 Member of Automation Alliance Designed for standardized IEC 61131-3 programming in five different languages. Other features: Configuration of the overall system including field buses and interfaces, extensive diagnostic functions, alarm handling, integrated visualization and open software interfaces. Programming in conformity with IEC 61131-3 For planning, programming, testing and commissioning of an automation application. The following functionalities are available: 5 standardized programming languages: Function Block Diagram (FBD), Instruction List (IL), Ladder Diagram (LD), Structured Text (ST), Sequential Function Chart (SFC) Free graphical function chart (CFC). Debugging functions for the program test o Single step o Single cycle o Breakpoint Offline simulation IEC 61131-3 commands can be simulated without a PLC being connected, including the relevant malfunctions. After the program test, the application can be downloaded to the control system. Sampling trace Timing diagrams for process variables and storage of data in a ring buffer with event trigger. Recipe management and watch lists Values of selected variables are displayed. Pre-defined values can be assigned to variables which can then be downloaded to the control system all at once (“Write recipe”). Ongoing values from the control system can also be pre-assigned for reading into the Watch and Recipe Manager, and stored in memory there (“Read recipe”). These functions are also helpful, for example, for setting and entering control parameters. Visualization Includes color change, moving elements, bitmaps, text display, allows input of setpoint values and display of process variables read from the PLC, dynamic bar diagrams, alarm and event management, function keys and ActiveX elements. Configurators of the communication interfaces: For PROFIBUS DP, CANopen, DeviceNet, Ethernet, Modbus and CS31. Open interfaces DDE and OPC. Programming Serial or via Ethernet or ARCNET networks. Engineering interface (optional) Provides access from the programming system to an external project database where the program source code of one or several automation projects is managed. Optionally, a version control system, such as Visual Source Safe, can be used in order to ensure data consistency of the program code for several different users and projects. Other features Comprehensive libraries Windows 32-bit standard Operating systems Windows 2000 and XP 6/4 1SDC007200C0202 0601_PLC.indd 4 17-11-2006 9:42:22 Automation Devices Scalable PLC AC500 with S500 I/O Devices The AC500 PLC family The new AC500 consists of different devices that can be combined and flexibly expanded to suit the customer’s individual requirements. It is also possible, for instance, to operate several field buses simultaneously in any desired combination with a single control system. Customers can choose between different CPU performance classes, which can even be easily replaced subsequently to meet increasing requirements. Our common engineering tool AC500 Control Builder provides standardized programming of the entire platform according to IEC 61131-3, as well as further features and utilities. PLC’s Scalable PLC AC500 with S500 I/O devices AC500 elements 1 Back-lighted LCD display and keypad 2 SD card slot 3 Plug-in communication modules (1 to max. 4) 1 4 Optionally with integrated Ethernet or ARCNET 2 5 FBP interface (for slave) 3 1 The CPUs are available in three performance classes which can all be programmed in five different languages. They provide an LCD display, an operator keypad, an SD card slot and two integrated serial interfaces. The CPUs can be simply plugged onto the CPU terminal base. Optionally, they are also available with integrated Ethernet or ARCNET. 6 Two serial interfaces for programming, ASCII, Modbus or CS31 field bus (master) 4 5 7 6 7 Expandable by up to seven local I/O modules 6/5 1SDC007200C0202 0601_PLC.indd 5 17-11-2006 9:42:49 Automation Devices Scalable PLC AC500 with S500 I/O Devices The AC500 PLC family The communication modules For connection to standard field bus systems and integration into existing networks. Up to four communication modules in any desired combination are allowed at one CPU. The CPU terminal base Available in three different versions, enables easy plugging of the CPU and one, two or four communication modules. The S500 I/O modules Digital and analog modules in different versions. They can be simply plugged onto the terminal units – for local expansion of the CPU (max. seven modules) and decentralized expansion via the FBP interface. Flexible use thanks to configurable channels. The terminal units Multi-purpose usage for both digital and analog I/Os, for 1, 2 and 3-wire designs. Enable simple prewiring without electronics. For 24 V DC and 230 V AC, available with spring- or screw-type terminals, as desired. The FBP interface module With embedded digital I/Os and a field-bus-neutral interface for connecting the chosen FBP connector. For decentralized expansion of the AC500 system by up to seven I/O modules (incl. max. 4 analog modules). Please refer to the FieldBusPlugs catalog for further information about the FBP connector. The currently available FBP field bus plugs are listed in the paper 2CDC 120 141 D0201. The SD card Optional for data logging, downloading and uploading the user program without a PC or a firmware update for all devices (CPU, couplers or I/O modules). Simple integration in the field level Integration of the S500 I/O modules in the field level is performed using a FieldBusPlug, depending on the used FBP connector (e.g. ProfibusDP or DeviceNet). Using the FBP, the AC500 can also be operated as a field bus slave. Bus-neutral field devices: Circuit breaker Universal Motor Controller Motor starter AC500 slave S500 remote I/Os Soft starters Wireless proximity switches 6/6 1SDC007200C0202 0601_PLC.indd 6 17-11-2006 9:47:45 Automation Devices Scalable PLC AC500 with S500 I/O Devices Overview of AC500 CPUs Details Type Supply voltage 24 V DC Total memory SDRAM (kB) Flash (kB) SRAM (kB) PM571 PM571-ETH PM581 PM581-ETH PM581-ARC PM591 PM591-ETH PM591-ARC 24 V DC 24 V DC 24 V DC 4096 1024 128 8192 2048 512 32768 8192 2048 Program memory Flash EPROM and RAM [kB] 64 256 4096 Integrated data memory [kB] 21, incl. 1 kB RETAIN 288, incl. 32 kB RETAIN 3072, incl. 512 kB RETAIN Plug-in memory card [SD card] 128 MB 128 MB 128 MB Cycle time for 1000 instructions in ms binary word floating-point 0.3 0.3 6 0.15 0.15 3 0.05 0.05 0.5 Max. number of centralized inputs/outputs digital inputs digital outputs analog inputs analog outputs 224 168 112 112 224 168 112 112 224 168 112 112 Max. number of decentralized inputs/outputs Data buffering depends on the used field bus battery battery battery Real-time clock x x x Program execution cyclical time-controlled multi tasking x x x x x x x x x User program protection by password x x x x terminal block x x terminal block x x terminal block x x SUB-D x x SUB-D x x SUB-D x x RJ45 x RJ45 COM1: RS232/RS485 configurable connection programming, Modbus, ASCII, CS31 COM2: RS232/RS485 configurable connection programming, Modbus, ASCII Integrated Ethernet coupler Connection Ethernet x RJ45 Integrated ARCNET coupler Connection ARCNET Display and 8 function keys Function x Coax x RUN/STOP status, diagnosis x RUN/STOP status, diagnosis x Coax x RUN/STOP status, diagnosis Timers unlimited unlimited unlimited Counters unlimited unlimited unlimited x x x x x x x x x x x x x x x x x x Function Block Diagram (FBD) Instruction List (IL) Ladder Diagram (LD) Structured Text (ST) Sequential Function Chart (SFC) Continuous Function Chart (CFC) Approvals PLC’s Internal interfaces CE, GL, DNV, BV, RINA, LRS, cUL 6/7 1SDC007200C0202 0601_PLC.indd 7 17-11-2006 9:53:03 Automation Devices Scalable PLC AC500 with S500 I/O Devices Overview of S500 I/O modules Digital I/O modules Supply voltage DI524 DC532 DX522 DX531 24 V DC 24 V DC 24 V DC 24 V DC Number of digital inputs and outputs DI/DO/DC (configurable channels) 32 / - /- 16 / -/ 16 8/ 8/- 8 /4 / - Input voltage 24 V DC 24 V DC 24 V DC 115 ... 230 V AC Input time delay in ms configurable 0.1/ 1/ 8/ 32 configurable 0.1 / 1/ 8 / 32 configurable 0.1 / 1/ 8 / 32 typ. 20 Inputs as fast counters* 2 2 2 Max. counting frequency in kHz 50 50 50 Outputs transistor 24 V DC, 0.5 A relay 230 V AC, 3 A x Total current per module 8A Short circuit / overload protection x1) x1) yes Potential isolation per module per module per module per module Operating state indicators status indication for each input/output supply voltage fault indication yellow LED green LED red LED yellow LED green LED red LED yellow LED green LED red LED yellow LED green LED red LED Analog I/O modules AX522 Supply voltage 24 V DC Number of analog inputs 8 Input ranges 0 ... 10 V, ±10 V 0/ 4 ... 20 mA Pt100 -50 ... +400 °C 2 /3-wire Pt1000 -50 ... +400 °C 2 /3-wire Ni1000 -50 ... +150 °C 2/3-wire Number of analog outputs 8 Output ranges ±10 V 0/ 4 ... 20 mA (max. 4 current outputs) Short circuit / overload protection x Resolution 12 bits + sign Potential isolation per module Operating state indicators status indication for each input/output supply voltage fault indication yellow LED green LED red LED 6/8 1SDC007200C0202 0601_PLC.indd 8 17-11-2006 9:53:03 Automation Devices Scalable PLC AC500 with S500 I/O Devices Overview of S500 I/O modules Interface modules DC505-FBP DC551-CS31 Field buses PROFIBUS DP*) CANopen*) DeviceNet*) Modbus RTU*) CS31 Interface via FBP integrated Supply voltage 24 V DC 24 V DC Number of digital inputs and outputs DI/DO/DC (configurable channels) 8 / –/ 8 8 / – /16 Power supply 24 V DC via FBP 24 V DC Input voltage 24 V DC 24 V DC Input time delay configurable 0.1 / 1 / 8 / 32 ms configurable 0.1 / 1 / 8 / 32 ms Transistor outputs output voltage / current 24 V DC / 0.5 A 24 V DC/ 0.5 A Total current per module 4A 8A Short circuit / overcurrent protection yes yes green LED green LED green LED Operating state indicators supply voltage FBP communication CS31 communication Sumcheck error I/O bus communication status indication for each input / output supply voltage I/Os fault indication I/Os Potential isolation red LED green LED yellow LED green LED red LED green LED red LED green LED yellow LED green LED red LED from the bus per module from the bus per module PLC’s *) depending on the FBP; the module itself is fieldbus-neutral 6/9 1SDC007200C0202 0601_PLC.indd 9 17-11-2006 9:53:04 Automation Devices Scalable PLC AC500 with S500 I/O Devices AC500 System data Operating and environmental conditions Voltages according to EN 61131-2 24 V DC 120 V AC 230 V AC 120–240 V AC Process and supply voltage Absolute limits Residual ripple Polarity reversal protection Supply voltage Frequency Supply voltage Frequency Wide voltage input Voltage Frequency 24 V DC (–15 %, +20 % without residual ripple) 19.2 V ... 30 V incl. residual ripple < 5% 10 s 120 V AC (–15 %, +10 %) 47 Hz ... 62.4 Hz /50 ... 60 Hz (–6 %, +4 %) 230 V AC (–15 %, +10 %) 47 Hz ... 62.4 Hz / 50 ... 60 Hz (–6 %, +4 %) 102 V ... 264 V / 120 V ... 240 V (–15 %, +10 %) 47 Hz ... 62.4 Hz / 50 ... 60 Hz (– 6 %, +4 %) Power failure bridging time according to EN 61131-2 DC supply AC supply Failure < 10 ms, time between 2 failures > 1 s, PS2 Failure < 0.5 periods, time between 2 failures > 1 s Operation Storage Transport 0 °C ... +55 °C for horizontal mounting –25 °C ... +75 °C –25 °C ... +75 °C 50 ... 95 %, no condensation Operation Storage > 800 hPa /< 2000 m > 660 hPa / < 3500 m Temperature Humidity Air pressure Creepage distances and clearances The creepage distances and clearances correspond to Overvoltage Category II, Pollution Severity 2 Electromagnetic compatibility Interference immunity against electrostatic discharge (ESD) interference voltage with air discharge interference voltage with contact discharge acc. to EN 61000-4-2, Zone B, Criteria B 8 kV 4 kV* Interference immunity against radiated interferences (CW radiated) Test field strength acc. to EN 61000-4-3, Zone B, Criteria A 10 V/m Interference immunity against transient interference voltages (burst) acc. to EN 61000-4-4, Zone B, Criteria B Interference immunity against conduction-bound interferences (CW conducted) Test voltage acc. to EN 61000-4-6, Zone B, Criteria A 3V Zone B Impulse voltage acc. to EN 61000-4-5, Zone B, Criteria B Emitted interferences acc. to EN 55011, Group 1, Class A Mechanical data Connection type / terminals Mounting Degree of protection Housing Vibration resistance Vibration resistance with SD card plugged in Shock resistance Device mounting DIN top-hat rail acc. to DIN EN 50022 Screw mounting Torque horizontal IP 20 acc. to UL 94 all three axes 2 Hz ... 15 Hz, continuously 3.5 mm 15 Hz ... 150 Hz, continuously 1 g (4 g in preparation) 15 Hz ... 150 Hz, continuously 1 g all three axes 15 g, 11 ms, semi-sinusoidal 35 mm, overall height 7,5 mm or 15 mm Screws with 4 mm diameter 0.6 Nm * Use with higher interference voltages is possible but requires additional external measures 6/10 1SDC007200C0202 0601_PLC.indd 10 17-11-2006 9:53:04 Automation Devices Scalable PLC AC500 with S500 I/O Devices Dimensional drawings CPU terminal base TB511, TB521 and TB541 Approvals cUL GL, Germany DNV, Norway PLC’s I/O expansion and interface modules BV, France RINA, Italy Lloyd´s Register Of Shipping LRS, United Kingdom 6/11 1SDC007200C0202 0601_PLC.indd 11 17-11-2006 9:53:05 Automation Devices Scalable PLC AC500 with S500 I/O Devices Ordering data AC500 CPUs 2 internal serial interfaces, RS232 /RS485 configurable Display and 8 function keys for diagnosis and status Centrally expandable with up to 7 expansion modules Simultaneous operation of up to 4 external communication modules in any desired combination Optional SD card for data storage and program backup AC500 CPUs, type PM571 Type Program memory Cycle time in ms 1000 instructions Bit / Word/Float. point Integrated coupler Order code Price PM571 64 kB 0.3 / 0.3 / 6 – 1SAP 130 100 R0100 0.135 PM571-ETH 64 kB 0.3 / 0.3 / 6 Ethernet 1SAP 130 100 R0170 0.15 Weight per piece kg AC500 CPUs, type PM581 Type Program memory Cycle time in ms 1000 instructions Bit / Word/Float. point Integrated coupler Order code Price PM581 256 kB 0.15 / 0.15 / 3 – 1SAP 140 100 R0100 0.135 PM581-ETH 256 kB 0.15 / 0.15 / 3 Ethernet 1SAP 140 100 R0170 0.15 PM581-ARCNET 256 kB 0.15 / 0.15 / 3 ARCNET available 2007 0.16 Weight per piece kg AC500 CPUs, type PM591 Type Program memory Cycle time in ms 1000 instructions Bit / Word/Float. point Integrated coupler Order code Price PM591 4096 kB 0.05 / 0.05 / 0.5 – 1SAP 150 100 R0100 0.135 PM591-ETH 4096 kB 0.05 / 0.05 / 0.5 Ethernet 1SAP 150 100 R0170 0.15 PM591-ARCNET 4096 kB 0.05 / 0.05 / 0.5 ARCNET available 2007 0.16 Weight per piece kg Ethernet communication module 10/100 Mbit/s, full/half duplex with auto-sensing 2-port switch integrated Transport protocols TCP/IP, UDP/IP, Modbus TCP Simultaneous operation of max. 4 CM577-ETH modules at one CPU No external power supply required Type Protocol Interfaces Order code CM577-ETH TCP/IP, UDP/IP, Modbus TCP 2 x RJ45 1SAP 170 700 R0001 Price Weight per piece kg 0.115 6/12 1SDC007200C0202 0601_PLC.indd 12 17-11-2006 9:53:12 Automation Devices Scalable PLC AC500 with S500 I/O Devices Ordering data Profibus DP communication module Profibus DP master with up to 12 Mbit /s Simultaneous operation of max. 4 CM572-DP modules at one CPU No external power supply required Type Interface Order code CM572-DP Sub-D socket 1SAP 170 200 R0001 Price Weight per piece kg 0.115 DeviceNet communication module Type Interface Connection Order code CM575-DN Plug-in terminal block Spring-type terminals 1SAP 170 500 R0001 Price Weight per piece kg 0.115 CANopen communication module Type Interface Connection Order code CM578-CN Plug-in terminal block Spring-type terminals 1SAP 170 800 R0001 Price Weight per piece kg 0.115 Terminal base PLC’s For mounting and connection of the CPUs and communication modules 1 to 4 plug-in communication modules Connection for communication coupler integrated in the CPU I/O interface for direct connection of up to 7 expansion modules Fieldbus-neutral FieldBusPlug-Slave interface Connection COM1: 9-pole pluggable terminal block Connection COM2: 9-pole SUB-D (socket) Type Number of coupler slots Connection for coupler integrated in the CPU Order code TB511-ETH 1 Ethernet RJ45 1SAP 111 100 R0170 TB521-ETH 2 Ethernet RJ45 1SAP 112 100 R0170 TB541-ETH 4 Ethernet RJ45 1SAP 114 100 R0170 TB521-ARCNET 2 ARCNET COAX available 2007 Price Weight per piece kg 0.215 Interface modules For decentralized I/Os DC505-FBP Communication via FieldBusPlug with Profibus DP, CANopen, DeviceNet, Modbus Fieldbus-dependent FieldBusPlug required* DC551-CS31 Communication via internal interface with CS31 system bus Plug-in electronic modules, terminal block TU5xx required DC: Channels can be individually configured as inputs or outputs Type Number of DI/DO/ DC Input signal Output signal Order code Price DC505-FBP 8 / –/ 8 24 V DC Trans. 24 V DC, 0.5 A 1SAP 220 000 R0001 0.3 DC551-CS31 8 / –/16 24 V DC Trans. 24 V DC, 0.5 A 1SAP 220 500 R0001 0.3 Weight per piece kg * Please refer to the FieldBusPlugs catalog for information about FBP. The currently available FBP field bus plugs are listed in the paper 2CDC 120 141 D02**. 6/13 1SDC007200C0202 0601_PLC.indd 13 17-11-2006 9:54:00 Automation Devices Scalable PLC AC500 with S500 I/O Devices Ordering data Digital input/output modules For central expansion of the AC500 CPUs For decentralized expansion in combination with interface module DC505-FBP or DC551-CS31 Plug-in electronic modules, terminal block TU5xx required DC: Channels can be individually configured as inputs or outputs Type Number of DI/ DO/DC Input signal Relay / transistor outputs Output signal Order code DI524 32 / –/ – 24 V DC – – 1SAP 240 000 R0001 0.2 DC532 16 / –/ 16 24 V DC Transistor 24 V DC, 0.5 A 1SAP 240 100 R0001 0.2 1) 1SAP 245 200 R0001 0.3 1) 1SAP 245 000 R0001 0.3 DX522 8/ 8/ – DX531 1) 24 V DC 8/ 4/ – 230 V AC Relay 230 V AC, 3 A Relay 230 V AC, 3 A Price Weight per piece kg Relay outputs, changeover contacts Analog input/output modules For central expansion of the AC500 CPUs For decentralized expansion in combination with interface module DC505-FBP or DC551-CS31 (max. 4 analog modules) Plug-in electronic modules, terminal block TU5xx required Range individually configurable for each channel Resolution 12 bits + sign Type Number of AI / AO Input signal Output signal Order code Price AX522 8/8 0 ... 10 V, ±10 V 0 /4 ... 20 mA Pt100, Pt1000 Ni1000 ±10 V 0 /4 ... 20 mA (max. 4 current ouputs) 1SAP 250 000 R0001 Weight per piece kg 0.2 Terminal blocks For digital and analog expansion modules and interface modules Please note: For modules with relay outputs, terminal blocks for 230 V AC (TU531 / TU532) are required! For the module-terminal block assignments, please consult the table! TU505-FBP screw-type DC505-FBP x TU506-FBP spring-type TU515 screw-type TU516 spring-type TU531 screw-type TU532 spring-type TU551-CS31 TU552-CS31 screw-type spring-type x DC551-CS31 x DI524 x x DC532 x x DX522 x x DX531 x x AX522 Type x for Supply TU505-FBP FBP interface modules TU506-FBP FBP interface modules x x Connection type Order code Price Screw-type terminals 1SAP 210 200 R0001 0.3 Weight per piece kg Spring-type terminals 1SAP 210 000 R0001 0.3 TU515 I/O modules 24 V DC Screw-type terminals 1SAP 212 200 R0001 0.3 TU516 I/O modules 24 V DC Spring-type terminals 1SAP 212 000 R0001 0.3 TU531 I/O modules AC / relay 230 V AC Screw-type terminals 1SAP 217 200 R0001 0.3 0.3 TU532 230 V AC Spring-type terminals 1SAP 217 000 R0001 TU551-CS31 CS31 interface modules 24 V DC Screw-type terminals 1SAP 210 600 R0001 0.3 TU552-CS31 CS31 interface modules 24 V DC Spring-type terminals 1SAP 210 400 R0001 0.3 I/O modules AC / relay 6/14 1SDC007200C0202 0601_PLC.indd 14 17-11-2006 9:54:01 Automation Devices Scalable PLC AC500 with S500 I/O Devices Ordering data Accessories for AC500 Type for Description Order code Price TK501 AC500 CPUs COM2 Programming cable Sub-D / Sub-D, length 5 m 1SAP 180 200 R0001 0.4 TK502 AC500 CPUs COM1 Programming cable Sub-D / terminal block, length 5 m 1SAP 180 200 R0101 0.4 MC502 AC500 CPUs Memory card (SD card) 128 MB 1SAP 180 100 R0001 0.1 TA521 AC500 CPUs Lithium battery for data buffering 1SAP 180 300 R0001 0.1 TA523 I/O modules Pluggable marker holder for I/O modules, packing unit incl. 10 pcs. 1SAP 180 500 R0001 0.3 TA524 Terminal base Communication module, dummy housing 1SAP 180 600 R0001 TA525 I/O modules White labels, packing unit incl. 10 pcs. 1SAP 180 700 R0001 0.1 TA526 CPU terminal base Accessories for back plate mounting, packing unit incl. 10 pcs. 1SAP 180 800 R0001 0.2 Weight per piece kg Programming package PS501 Control Builder For all AC500 CPUs All programming languages according to IEC 61131-3 Contains: 5 programming languages, sampling - trace, debugging, offline simulation, integrated visualization, trace recording (multi-channel), recipe management, Continuous Function Chart Languages: German / English / French Scope of delivery: Software, libraries and documentation (PDF) on CD-ROM for Description Order code PS501 all AC500 CPUs Programming package PS501 Control Builder AC500 1SAP 190 100 R0001 Price Weight per piece kg PLC’s Type 0.3 Please refer to the FieldBusPlugs catalog for FieldBusPlug (FBP) ordering data . The currently available FBP field bus plugs are listed in the paper 2CDC 120 141 D02**. 6/15 1SDC007200C0202 0601_PLC.indd 15 17-11-2006 9:54:02 Automation Devices Small and Compact PLCs AC31 The AC31 PLC family Modbus Ethernet ARCNET CANopen DeviceNet Modbus Profibus DP CS31 The AC31 PLC family AC31 offers compact, high performance CPUs in varying designs with the possibility of decentral networking. busses or network protocols, e.g. Ethernet + PROFIBUS DP, ARCNET + CANopen or CANopen + Ethernet. All CPUs are universally programmable according to IEC 61131-3, beginning with the small PLCs (series 40..50) up to the high-performance compact PLCs (series 90). The couplers are integrated within the standard housing of the CPU in order to save space. Tools for the configuration of the field busses used are already an integral part of the software package 907 AC 1131. They occupy only small space and offer high functionality with up to 1 MByte of user memory, with 60 integrated I/Os (analog and digital), with two serial interfaces (both of which are configurable for MODBUS or ASCII) and with a plug-in smart media card for loading user programms or for data storage. The components of AC31 series 40..50 and of AC31 series 90 can be mixed as desired. This way it is even possible to combine I/O modules of series 40..50 with the compact controllers of series 90 or vice versa to combine I/O modules of series 90 with a small PLC of series 50. Up to two further communication interfaces with their own processors are already integrated within the CPUs. The user can choose varying combinations of integrated field 6/16 1SDC007200C0202 0601_PLC.indd 16 17-11-2006 9:54:02 Automation Devices Small and Compact PLCs AC31 Safety PLC AC31-S 40 serie 50 serie 07KT94-S 07KT95 07KT96 07KT97 07KT98 MODBUS x x x x x x x Ethernet x x x x CANopen x x Profibus DP x x x x x x x x x x ARCNET x DFÜ RCOM x x x DeviceNet CS31 system bus x x x x Safety first: Safety PLC AC31-S Economical The Advant Controller 31-S requires no redundant CPU for safety functions, so this system is lowcost both as regards hardware and as regards engineering. The I/O units at a local level already feature an internal 2-channel structure and monitor themselves, including a passive error and fault detection. One set of hardware for all functions The hardware of the Advant Controller 31-S supports the safety functions and operating functions simultaneously. On the AC31 safety field bus, safety-related I/O modules and AC31 standard I/Os can be mixed. The safety-related functions are programmed with the help of certified function blocks. PLC’s Nowadays, machine and plant manufacturers are confronted by ever more extensive and stringent safety conditions, in line with the demand that the safety of machines and systems must be implemented optimally and in line with the “state of the art” for protection of man, machine and the environment. The safety-related automation system AC31-S allows to design and standardize small distributed control units. They operate autonomously at a local level where the safety function is required. The relevant related inputs and outputs are installed in the field where the signal is detected or output. They are connected to their control units via the AC31 Safety Fieldbus. This helps, once again, to save on cables. These control units can be networked flexibly and are able to exchange data among each other or with a higher-level system. 6/17 1SDC007200C0202 0601_PLC.indd 17 17-11-2006 9:55:00 Automation Devices Small and Compact PLCs AC31 Overview of AC31 CPUs Small PLC AC31 series 40..50 Details Program memory Flash EPROM and RAM [kB] Supply voltage 24 V DC 120 / 230 V AC Plug-in Smart Media Card Cycle time for 1 kB [ms] 100% binary values 65% binary values and 35% words Number of inputs and outputs Digital, internal (DI / DO / DC) DI/DO maximum Analog, internal (AI / AO) AI/AO maximum Digital inputs 24 V DC Digital outputs Transistor (T) 24 V DC, 0.5 A Relay (R) 120 / 230 V AC, 2 A Analog input ranges ± 10 V 0 ... 10 V, 0 ... 5 V, ± 5 V 0 ... 20 mA, 4 ... 20 mA PT100 (– 50 °C ... + 400 °C) PT100 (– 30 °C ... + 70 °C) PT100 (– 100 °C ... + 524 °C) configurable as DI Analog output ranges ± 10 V 0 ... 20 mA, 4 ... 20 mA Data buffering by battery Real-time clock Programming package 907 AC 1131 907 PC 331 AC31GRAF Program execution cyclical or time-controlled multitasking User program protection password Serial interfaces RS232 (programming, Modbus, ASCII) RS485 (CS31, Modbus, programming) Integrated potentiometers Data memory [kB] Timers Counters Fast counters (pieces / frequency) Interfaces / protocols CS31 ASCII MODBUS® Ethernet ARCNET Profibus DP CANopen DeviceNet AC31 Safety Fieldbus RCOM (additional coupler) Type CR41 CT41 CR42 CT42 KR51 34 x x x – 34 x x x – – x x – 0.4 1.2 8/6/– 110 –/– 36 8/6/– 110 3/– 36 8/6/– 1000 –/– 222 x x x – x – – 0.4 1.2 – x KT51 – x – – – – – – – x – x – – – – x – – x x – – – – – – – – – – integrated x – – integrated x x x x x x x x x x x x x x x 1 – 2 2 unlimited (42 at the same time) unlimited (function) 2 / 7 kHz 1 1 2 2 unlimited (42 at the same time) unlimited (function) 2 / 7 kHz – x x x – – – – – – x x x x – – – – – – 6/18 1SDC007200C0202 0601_PLC.indd 18 17-11-2006 9:55:00 Automation Devices Small and Compact PLCs AC31 Overview of AC31 CPUs Compact PLC AC31 series 90 Safety PLC AC31 series 90 KT96 KT97 KT98 KT94-S 480 480 480 1000 240 x – x x – x x – x x – x x – x – 0.22 – 0.22 – 0.22 – 0.07 – 0.22 12 / 8 / 0 1012 4/2 228 / 226 x 24 / 16 / 0 1032 – 224 / 224 x 24 / 16 / 8 1040 8/4 232 / 228 x 24 / 16 / 8 1040 8/4 232 / 228 x 24 / 16 / 8 992 8/4 224 / 224 x x – x – x – x – x – x x – – – – – – – – – – – – x x x x x – x x x x x x – x x x x x x – x x – optional x – – optional x x x optional x x x optional x x x optional x x – – x – – x – – x – – – x – x x x x x x x x – – x x x x x 2 – – 256, incl. 16 kB RETAIN unlimited unlimited 2 / 50 kHz 2 – – 256, incl. 16 kB RETAIN unlimited unlimited (function) 2 / 50 kHz 2 – – 256, incl. 16 kB RETAIN unlimited unlimited (function) 2 / 50 kHz 2 – – 1280, incl. 256 kB RETAIN unlimited unlimited 2 / 50 kHz 2 – – 256, incl. 16 kB RETAIN unlimited (80 at the same time) unlimited 2 / 50 kHz x x x – – – – – – x x x x – – – – – – x x x x x x x x x – x x x x x x x x x – x x x x – – – – – x x PLC’s KT95 6/19 1SDC007200C0202 0601_PLC.indd 19 17-11-2006 9:55:01 Automation Devices Small and Compact PLCs AC31 Overview of AC31 I/O modules Digital I/O modules Type Supply voltage 24 V DC 230 V AC Number of digital input and outputs (DI / DO / DC) Digital inputs 24 V DC Digital outputs Relay (R) 120 / 230 V AC, 2 A Transistor (T) 24 V DC, 2 A Transistor (T) 24 V DC, 0.5 A Short circuit- / overload-proof Interfaces / protocols CS31 field bus Profibus DP Connection type (1 = 1 wire, 3 = 3 wires) spring-type terminal screw-type terminal Bus modules series 50 *1) ICMK 14 F1 ICMK 14 F1 ICMK 14 N1 XI 16 E1 XO 16 N1 XO 08 Y1 XO 08 R1 XO 08 R2 XC 08 L1 XK 08 F1 XC 32 L1 *2) *3) x – – x x – internal internal 8/6/x 8/6/x 8/6/x 16 / - / x - / 16 / – -/8/– -/8/– -/8/– -/-/8 x 4/4/x - / - / 32 x x – – – x – – – – – x x – – – x – – x x – x – x x – – – x – – – – – x x x – – – – – x x x – x – x – – – – – – – – – – – – – – – – – 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 with HE10 conn. Analog I/O modules Type Supply voltage 24 V DC 230 V AC Number of analog inputs and outputs AI / AO / AC Analog input signals 0 ... 10 V ± 10 V ± 20 mA 0 ... 20 mA 4 ... 20 mA ± 50 mV, ± 500 mV, ± 5 V PT100, PT1000 thermocouple Analog output signals ± 10 V 0 ... 20 mA, 4 ... 20 mA ± 20 mA Short circuit- / overload-proof Interfaces / protocols CS31 field bus Profibus DP Connection type (1 = 1 wire, 3 = 3 wires) spring-type terminal screw-type terminal Display of channel number / value Remark: Series 40 .. 50 Only in connection with bus modules or CPU Series 40 .. 50 XM 06 B5 only with bus module or CPU XE 08 B5 XTC 08*4) Series 90 XC 32 L2*5) internal internal 07 AI 91 07 AC 91*6) x – x – 4/2/– 8/–/– 8 internal 8/–/– 8/–/– – / – / 16 – x x – x – x – – x x – x – x – – – – – – – – – x – – – – – – – – x – x – x x x – x – x x – – – x x – x – – – x – – – x – – – x – – – x x x – x – – – – – – – – x – x – 1 1 1 with HE10 1 1 1 1 1 connector 1 1 x x x – – – *4) Display for 8 internal channels. *5) Plus 24 configurable digital I/Os (DC). Same as XC 32 L1 but 8 of 32 DC can also be used as AI. *6) Incl. 1 x DI for shut-off of all AOs of the module. With 2 modes of operation: (1) 8 AI and 8 AO with resolution of 12 bits or (2) in pairs as AI or AO with 8 bits. 6/20 1SDC007200C0202 0601_PLC.indd 20 17-11-2006 9:55:02 Automation Devices Small and Compact PLCs AC31 Overview of AC31 I/O modules Bus modules series 50 Series 90 07 DI 92 07 DC 91 07 DC 92 07 TC90 / TC91 *7) x – x – x – x – – / – / 32 x 16 / 8 / 8 x – / – / 32 x 32 / 32 / – – – – x x – – x x – – x x – – – – x – x – x – x – – 1 – 1 – 1 – – Input / output modules Serie 90 07 DI 90-S 07 DO 90-S 07 AI 90-S x x x Number of safety-related digital I/Os (DI / DO ) 8/–/– –/8/– –/–/– Number of safety-related analog I/Os (AI / AO) Supply voltage 24 V DC –/– –/– 4/– Digital inputs 24 V DC x – – Digital outputs: transistor (T) 24 V DC, 0.5 A – x – Analog outputs: 4 ... 20 mA – – x Short circuit- / overload-proof x x x Interfaces / protocols AC31 Safety Fieldbus x x x Connection type (1 = 1 wire, 3 = 3 wires) screw-type terminal 1 1 1 Fault detection: short circuit overload wire break forbidden signal level range over- / underrun passive errors internal errors x – x x – x x x x – – – x x x – x x x x x Internal 2-channel structure x x x x x X Category 3 (EN954-1) Remark: PLC’s Safety-related I/O modules Input / output modules series 40...50 Only in connection with safety-related CPU KT94-S 6/21 1SDC007200C0202 0601_PLC.indd 21 17-11-2006 9:55:03 Automation Devices Small and Compact PLCs AC31 AC31 system data System data AC31 series 40..50 Operating and environmental conditions Environmental conditions • Temperature operation horizontal vertical 0 °C to + 55 °C 0 °C to + 40 °C storage – 40 °C to + 75 °C transport – 25 °C to + 75 °C • Humidity annual average for up to 30 days per year occasionally DIN 40040 Class F, no condensation < 75% 95% 85% • Air pressure operation storage DIN 40050 > 800 hPa ( < 2000 m) > 600 hPa ( < 3500 m) Mechanical data • Degree of protection IP 20 • Housing UL V2 • Vibration resistance CEI68-2-8 Test Fc • Shock resistance CEI68-2-27 Test Ea Supply voltage tolerances • 24 V DC 9.2 to 30 V (– 20%, + 25%) • 120 V AC (50 / 60 Hz) 97.75 to 126.5 V (– 18.5%, + 5.5%) • 230 V AC (50 / 60 Hz) 195.5 to 253 V (– 15%, + 10%) System data AC31 series 90 Operating and environmental conditions • Voltages 24 V DC process and supply voltage absolute limits residual ripple 24 V DC (+ 20%, – 15% without residual ripple) 19.2 V ... 30 V, incl. residual ripple < 5% 120 V AC supply voltage frequency 120 V AC (+ 10%, – 15%) 50 Hz (+ 5%, – 5%) or 60 Hz (+ 5%, – 5%) 230 V AC supply voltage frequency 230 V AC (+ 10%, – 15%) 50 Hz (+ 5%, – 5%) or 60 Hz (+ 5%, – 5%) • Power failure bridging time DC supply AC supply • Temperature operation storage transport • Humidity • Air pressure Failure <10 ms, time between 2 failures > 1 s Failure <0.5 periods, time between 2 failures > 1 s 0 °C to + 55 °C – 25 °C to + 75 °C – 25 °C to + 75 °C 50 ... 95%, no condensation operation storage > 800 hPa / < 2000 m > 660 hPa / < 3500 m Creepage distances and clearances Creepage distances and clearances correspond to Overvoltage Category II, Pollution Severity 2 6/22 1SDC007200C0202 0601_PLC.indd 22 17-11-2006 9:55:21 Automation Devices Small and Compact PLCs AC31 AC31 system data System data AC31 series 90 (continued) Test voltages 230 V circuits (mains, 230 V in-/outputs) against other circuits 2500 V 120 V circuits (mains) against other circuits 1500 V 24 V circuits (supply, 24 V inputs/outputs), if they are potentially isolated against other circuits 500 V CS31 bus against other circuits 500 V • Interference immunity against electrostatic discharge (ESD) – interference voltage with air discharge – interference voltage with contact discharge acc. to DIN 61000-4-2 8 kV 4 kV • Interference immunity against radiated interference (CW radiated) – Test field strength acc. to DIN 61000-4-5 10 V / m • Immunity against transient interference voltages / bursts – voltage supply (AC / DC) – digital inputs / outputs (24 V DC) – digital inputs / outputs (120 / 230 V DC) – analog inputs / outputs – CS31 system bus – serial interfaces (COM) – ARCnet acc. to DIN 61000-4-6 2 kV 1 kV 2 kV 1 kV 2 kV 0.5 kV 0.5 kV • Interference immunity against conduction-bound interferences (CW conducted) – test voltage acc. to DIN 61000-4-6 10 V • Emitted interferences PLC’s Electromagnetic compatibility acc. to EN 55011 Funkstörgrad A and acc. to EN 55022 Funkstörgrad A (communication modules only) Mechanical data • Connection type / terminals for terminal base ECZ Screw-type terminals for slot and crosstip screwdrivers, conductor diam.: max. 2 x 2.5 mm2 for plug-in terminal blocks (row terminals, large) Screw-type terminals for slot screwdrivers, conductor diam.: max. 2.5 mm2 for plug-in terminal blocks (row terminals, small) Screw-type terminals for slot screwdrivers, conductor diam.: max. 1.5 mm2 • Degree of protection IP 20 • Housing acc. to UL 94 • Vibration resistance for all three axes 10 Hz ... 57 Hz 57 Hz ... 150 Hz • Shock resistance cont.: peak: cont.: peak: 0.0375 mm 0.075 mm 0.5 g 1.0 g for all three axes 15 g, 11 ms, half-sinusoidal Device mounting DIN top-hat rail acc. to DIN EN 50022, for terminal base ECZ only: 35 mm, height 15 mm height 7.5 mm and 15 mm Screw mounting Screws, diameter 4 mm Interfaces Between CPU and I/O modules EIA RS-485 (CS31 system bus) For programming units and for connection to a terminal, 9-pole D-SUB socket EIA RS-232 6/23 1SDC007200C0202 0601_PLC.indd 23 17-11-2006 9:55:22 Automation Devices Small and Compact PLCs AC31 Dimensional drawings WxHxD [mm] 120 x 93 x 84 WxHxD [inches] 4.72 x 3.66 x 3.31 Mounting 84 C0332D 35 mm EN 50022 120 C0333D 93 CPUs series 40..50 and bus modules 35 mm DIN rail acc. to DIN EN 50 022 or screw mounting 07CR41/42, 07CT41/42, 07KR51, 07KT51 and ICMK 14 F1/N1 CPUs series 90 WxHxD [mm] 240 x 140 x 85 WxHxD [inches] 9.45 x 5.51 x 3.35 85 35 mm DIN rail acc. to DIN EN 50 022 or screw mounting C0318D 35 mm EN 50022 Mounting 07KT94, 07KT94-S, 07KT96, 07KT97 and 07KT98 Communication modules series 90 WxHxD [mm] 120 x 140 x 85 WxHxD [inches] 4.72 x 5.51 x 3.35 Mounting 35 mm DIN rail acc. to DIN EN 50 022 or screw mounting 07KP90, 07KP93 6/24 1SDC007200C0202 0601_PLC.indd 24 17-11-2006 9:55:22 Automation Devices Small and Compact PLCs AC31 Dimensional drawings 93 I/O modules and communication modules series 40..50 WxHxD [mm] 65 x 93 x 84.5 WxHxD [inches] 2.56 x 3.66 x 3.33 65 Germanischer Lloyd 35 mm DIN rail acc. to DIN EN 50 022 or screw mounting C0310D Mounting Approvals XI16E1, XO16N1, XO08R1, XO08Y1, XC08L1, XK08F1, XM06B5, XE06B5, 07KP53 Lloyds Register of Shipping I/O modules series 90 WxHxD [mm] 120 x 140 x 85 WxHxD [inches] 4.72 x 5.51 x 3.35 Mounting Germanischer Lloyd 35 mm DIN rail acc. to DIN EN 50 022 or screw mounting UL CSA Lloyds Register of Shipping 07DI92, 07DC91/92, 07AI91, 07AC91, 07DO90-2, 07DI90-S, AI90-S PLC’s TÜV, BG for AC 31-s DNV, Norway 6/25 1SDC007200C0202 0601_PLC.indd 25 17-11-2006 9:55:25 Automation Devices Small and Compact PLCs AC31 Ordering data for Small PLCs AC31 series 40..50 CPUs AC31 series 40 Description: see „Overview of CPUs“. Centrally expandable with up to 6 I/O modules. CRxx: relay outputs, CTxx: transistor outputs. Program memory without / with online changes: 34 [kB] / 17 [kB]. Integrated I/Os (DI / DO / AI) Integrated counter inputs / pulse outputs SB7667C3 Type Supply voltage 24 V DC 07 CR 41 8/6/– 2/– 120/230 VAC 07 CR 41 07 CT 41 8/6/– 2/1 07 CR 42 8/6/3 2/– 07 CT 42 8/6/3 2/1 Conncetion type Order code Price Weight p. piece kg Screw-type termin. 1SBP 260 020 R1001 0.400 Spring-type termin. 1SBP 260 520 R1001 0.400 Screw-type termin. 1SBP 260 021 R1001 0.800 Spring-type termin. 1SBP 260 521 R1001 0.800 Screw-type termin. 1SBP 260 022 R1001 0.400 Spring-type termin. 1SBP 260 522 R1001 0.400 24 V DC Screw-type termin. 1SBP 260 023 R1001 0.400 120/230 VAC Screw-type termin. 1SBP 260 024 R1001 0.800 24 V DC Screw-type termin. 1SBP 260 025 R1001 0.400 24 V DC CPUs AC31 series 50 Description: see „Overview of CPUs“. Integrated CS31 field bus. Centrally expandable with up to 6 I/O modules, decentrally with up to 31 I/O modules. KRxx: relay outputs, KTxx: transistor outputs. Program memory without / with online changes: 34 [kB] / 17 [kB]. SB7664C3 Type Integrated I/Os (DI / DO / AI) Integrated counter inputs / pulse outputs Supply voltage 24 V DC 07 KR 51 07 KR 51 8/6/– 2/– 120/230 VAC 07 KT 51 8/6/– 2/1 24 V DC Conncetion type Order code Price Weight p. piece kg Screw-type termin. 1SBP 260 010 R1001 0.400 Spring-type termin. 1SBP 260 510 R1001 0.400 Screw-type termin. 1SBP 260 011 R1001 0.800 Spring-type termin. 1SBP 260 511 R1001 0.800 Screw-type termin. 1SBP 260 012 R1001 0.400 Spring-type termin. 1SBP 260 512 R1001 0.400 Bus modules series 50 Description: see „Overview of I/O modules“. Integrated CS31 field bus. Centrally expandable with up to 6 I/O modules. Number of DI / DO Relay / transistor outputs Supply voltage ICMK 14 F1 8/6 Relay 24 V DC ICMK 14 F1 8/6 Relay 120/230 VAC SB7665C3 Type ICMK 14 F1 ICMK14 N1 8/6 Transistor 24 V DC Conncetion type Order code Price Weight p. piece kg Screw-type termin. 1SBP 260 050 R1001 0.400 Spring-type termin. 1SBP 260 550 R1001 0.400 Screw-type termin. 1SBP 260 051 R1001 0.800 Spring-type termin. 1SBP 260 551 R1001 0.800 Screw-type termin. 1SBP 260 052 R1001 0.400 Spring-type termin. 1SBP 260 552 R1001 0.400 Description: see „Overview of I/O modules“. Integrated MODBUS RTU slave. Automatic baudrate adaptation. Centrally expandable with up to 6 I/O modules (digital or analog modules). Type Number of DI / DO Relay / transistor outputs Supply voltage Conncetion type Order code Price Weight p. piece kg ICMK 14 F1-M 8 / 6 Relay 24 V DC Screw-type termin. 1SBP 260 053 R1001 0.400 ICMK 14 F1-M 8 / 6 Relay 120/230 V AC Screw-type termin. 1SBP 260 054 R1001 0.800 6/26 1SDC007200C0202 0601_PLC.indd 26 17-11-2006 9:55:28 Automation Devices Small and Compact PLCs AC31 Ordering data for Small PLCs AC31 series 40..50 Digital I/O modules series 40..50 SB7666C2 Description: see „Overview of I/O modules“. Type Number of DI / DO / DC Input signal Output signal XI 16 E1 16 / – / – 24 V DC – XO 16 N1 – / 16 / – – 24 V DC, 0.5 A XO 08 Y1 –/8/– – 24 V DC, 2 A XO 08 R1 XO 08 R2*) –/8/– – –/8/– – 250 V AC, 2 A 250 V AC, 2 A XI 16 E1 XC 08 L1 –/–/8 24 V DC 24 V DC, 0.5 A XK 08 F1 4/4/– 24 V DC 250 V AC, 2 A – / – / 32 24 V DC 24 V DC, 0.5 A **) XC 32 L1 Connection type Order code Price Weight p. piece kg Screw-type termin. 1SBP 260 100 R1001 0.220 Spring-type termin. 1SBP 260 600 R1001 0.220 Screw-type termin. 1SBP 260 105 R1001 0.220 Spring-type termin. 1SBP 260 605 R1001 0.220 Screw-type termin. 1SBP 260 108 R1001 0.220 Spring-type termin. 1SBP 260 608 R1001 0.220 Screw-type termin. 1SBP 260 101 R1001 0.220 Spring-type termin. 1SBP 260 601 R1001 0.220 Screw-type termin. 1SBP 260 109 R1001 0.220 Spring-type termin. 1SBP 260 609 R1001 0.220 Screw-type termin. 1SBP 260 102 R1001 0.220 Spring-type termin. 1SBP 260 602 R1001 0.220 Screw-type termin. 1SBP 260 104 R1001 0.220 Spring-type termin. 1SBP 260 604 R1001 0.220 HE10 connector 0.220 1SBP 260 110 R1001 *) 8 normally open outputs, 4 of them can also be configured as normally closed outputs **) 4 counters 20 kHz / 4 frequency meters can be connected to prewiring system INTERFAST. HE10 not included. Analog I/O modules series 40..50 SB7668C2 XM 06 B5 Type Number of Input AI / AO signal XM 06 B5 4/2 XE 08 B5 XC 32 L2*) 8/– 8/– Output signal ± 10 V, + 10 V, ± 20 mA 0 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA PT100, PT1000 ± 10 V, ± 20 mA – 4 ... 20 mA, PT100, PT1000 0 - 10 V – Connection type Order code Price Weight p. piece kg Screw-type termin. 1SBP 260 103 R1001 0.220 Spring-type termin. 1SBP 260 603 R1001 0.220 Screw-type termin. 1SBP 260 106 R1001 0.220 Spring-type termin. 1SBP 260 606 R1001 0.220 HE10 connector 0.220 1SBP 260 111 R1001 PLC’s Description: see „Overview of I/O modules“. *) Plus 24 configurable digital I/Os (DC). Same as XC 32 L1 but 8 of 32 DC can also be used as analog inputs. 4 counters 20 kHz / 4 frequency meters can be connected to prewiring system INTERFAST. HE10 not included. Communication modules for CPUs of series 40..50 Networking interface for small PLC AC31 series 40..50. Connection to CPU via ribbon cable. Voltage supply from CPU. Cable: see accessories. Type Protocol Software Interfaces 07 KP 53 MODBUS included 2 (in AC1131 & Modbus RTU, Master or Slave AC31GRAF) (RS232/RS485) Order code Price 1SBP 260 162 R1001 Weight p. piece kg 0.220 Ethernet interface for series 40 ..50 CPU external accessory connected to the serial mini DIN of CPU - powered by CPU. Type Protocol Interface Order code e-AC31 MODBUS TCP programming RJ45 1SBP 260 165 R1002 Price Weight p. piece kg 0.200 6/27 1SDC007200C0202 0601_PLC.indd 27 17-11-2006 9:55:33 Automation Devices Small and Compact PLCs AC31 Ordering data - Accessories for series 40..50 Display series 40..50 SB7628C3 External 24 V DC supply. Type Description Order code XTC 08 Display for 8 internal channels (4 digits + sign + selected channel) 1SBP 260 107 R1001 Price Weight p. piece kg 0.500 07 SK 50 Accessories for series 40..50 SB7630C3 Type Accessory for Order code Price Weight p. piece kg 07 SK 50 Programming cable. PC-Sub D, 9 poles 1SBN 260 200 R1001 0.220 07 SK 52 Programming cable without connector 1SBN 260 202 R1001 on PC side 0.220 Simulation device for CPUs, 8 switches 1SAY 110 811 R0001 0.100 Communication cable MODBUS/ASCII, 1SBN 260 201 R1001 PC-Sub D9 plug CPUs series 40..50, MODBUS coupler KP53 Communication cable MODBUS/ASCII 1SBN 260 203 R1001 without connector on PC side 0.220 CPUs series 40..50 07 SG 50 07 ST 50 Description 07 SK51 07 SK 53 LAF100/HE10- I/O modules 20/UNI/662/UL* XC32L1 / XC32L2 Cable with HE10 connector for exten. and naked wire on the other side, cable length: 1 meter 003900706 LAF150/HE10- I/O modules 20/UNI/662/UL* XC32L1 / XC32L2 Cable with HE10 connector for exten. and naked wire on the other side, cable length: 1.5 meters 003900825 LAF200/HE10- I/O modules 20/UNI/662/UL* XC32L1 / XC32L2 Cable with HE10 connector for exten. and naked wire on the other side, cable length: 2 meters 003900906 LAF300/HE10- I/O modules 20/UNI/662/UL* XC32L1 / XC32L2 Cable with HE10 connector for exten. and naked wire on the other side, cable length: 3 meters 003901104 LAF500/HE10- I/O modules 20/UNI/662/UL* XC32L1 / XC32L2 Cable with HE10 connector for exten. and naked wire on the other side, cable length: 5 meters 003901322 0.220 07 ST 50 CPUs and bus modules 2-tier screw-type terminal for digital series 40..50, 3-wire sensors / actuators, 2 pieces digital I/O modules 1SBN 260 300 R1001 0.220 07 ST 51 XM06B5, XE08B5 2-tier screw-type terminal for analog 3-wire sensors, 2 pieces 1SBN 260 301 R1001 0.220 2-tier spring-type terminal for digital 3-wire sensors / actuators, 2 pieces 1SBN 260 302 R1001 0.052 07 ST 52 07 ST 54 CPUs and bus modules Set of spring-type terminals series 40..50 1SBN 260 311 R1001 0.052 07 ST 55 XI16E1, XO16N1, XE08B5 Set of spring-type terminals 1SBN 260 312 R1001 0.052 07 ST 56 XO08R1, XC08L1, XK08F1 Set of spring-type terminals 1SBN 260 313 R1001 0.052 07 ST 57 XM06B5 Set of spring-type terminals 1SBN 260 314 R1001 0.052 Series 40..50 Labels for marking of I/O channels 1SBN 260 310 R1001 Documentation Series 40..50 English 1SBC 260 400 R1001 0.200 Documentation Series 40..50 French 1SBC 260 401 R1001 0.200 *) refer to prewiring system INTERFAST documentation for additional information. INTERFAST harnesses are also available for series 40..50 CPUs + remote modules XI16E1, XO16N1, DC92. 6/28 1SDC007200C0202 0601_PLC.indd 28 17-11-2006 9:55:37 Automation Devices Small and Compact PLCs AC31 Ordering data for Compact PLCs AC31 series 90 Compact PLCs AC31 series 90 07_KT_94_perspektive Description: see „Overview of CPUs“. Integrated CS31 field bus. Optional: Battery, Smart Media Card for data storage and user program backup (refer to accessories). Type Integrated digital I/Os (DI / DO / DC) Integrated analog I/Os (AI / AO) Counter inputs Program memory [kB] Order code Price Weight p. piece kg 07 KT 95 12 / 8 / – 4/2 2 480 GJR5 252 800 R0200 1.3 07 KT 96 24 / 16 / – –/– 2 480 GJR5 252 900 R0200 1.3 07 KT 97 24 / 16 / 8 8/4 2 480 GJR5 253 000 R0200 1.3 07 KT 95 Compact PLCs AC31 series 90 with up to 2 internal communication processors 07_KT_94_perspektive 07 KT 97 07 KT 98 Type Processor 1 Processor 2 Program memory [kB] Order code Price Weight p. piece kg 07 KT 97 - Profibus Profibus DP – 480 GJR5 253 000 R0220 1.3 07 KT 97 - CANopen CANopen – 480 GJR5 253 000 R0280 1.3 07 KT 97 - Ethernet Ethernet – 480 GJR5 253 000 R0270 1.3 07 KT 97 - ARCNET ARCNET – 480 GJR5 253 000 R0260 1.3 07 KT 97 - Ethernet - ARCNET Ethernet ARCNET 480 GJR5 253 000 R0276 1.3 07 KT 97 - Ethernet - Profibus Ethernet Profibus DP 480 GJR5 253 000 R0272 1.3 07 KT 97 - Ethernet - CANopen Ethernet CANopen 480 GJR5 253 000 R0278 1.3 07 KT 97 - Ethernet - Ethernet Ethernet Ethernet 480 GJR5 253 000 R0277 1.3 07 KT 97 - ARCNET - Profibus ARCNET Profibus-DP 480 GJR5 253 000 R0262 1.3 07 KT 97 - ARCNET - CANopen ARCNET CANopen 480 GJR5 253 000 R0268 1.3 07 KT 98 - Profibus Profibus DP – 1000 GJR5 253 100 R0220 1.3 07 KT 98 - CANopen CANopen – 1000 GJR5 253 100 R0280 1.3 07 KT 98 - Ethernet Ethernet – 1000 GJR5 253 100 R0270 1.3 07 KT 98 - ARCNET ARCNET – 1000 GJR5 253 100 R0260 1.3 07 KT 98 - Ethernet - ARCNET Ethernet ARCNET 1000 GJR5 253 100 R0276 1.3 07 KT 98 - Ethernet - Profibus Ethernet Profibus-DP 1000 GJR5 253 100 R0272 1.3 07 KT 98 - Ethernet - CANopen Ethernet CANopen 1000 GJR5 253 100 R0278 1.3 07 KT 98 - Ethernet - Ethernet Ethernet Ethernet 1000 GJR5 253 100 R0277 1.3 07 KT 98 - ARCNET - Profibus ARCNET Profibus-DP 1000 GJR5 253 100 R0262 1.3 07 KT 98 - ARCNET - CANopen ARCNET CANopen 1000 GJR5 253 100 R0268 1.3 PLC’s 07_KT_94_perspektive Description: see „Overview of CPUs“. Integrated CS31 field bus. Number of I/Os identical with 07 KT 97. Optional: Battery, Smart Media Card for data storage and user program backup (refer to accessories). 6/29 1SDC007200C0202 0601_PLC.indd 29 17-11-2006 9:55:38 Automation Devices Small and Compact PLCs AC31 Ordering data for Compact PLCs AC31 series 90 Digital I/O modules series 90 07_DI_92_perspektive Description: see „Overview of I/O modules“. Integrated CS31 field bus. DC: Channels can be individually configured as input or output. 07_DC_92_perspektive 07 DI 92 Type Number of Input DI / DO / DC signal Output signal Details Order code 07 DI 92 32 / – / – 07 DC 91 16 / 8 / 8 07 DC 92 – / – / 32 07 TC 90 07 TC 91 Price Weight p. piece kg 24 V DC – Input delay 7 ms GJR5 252 400 R0101 0.25 24 V DC 24 V DC 0.5 A (T) Input delay 7 ms GJR5 251 400 R0202 0.25 24 V DC 24 V DC 0.5 A (T) GJR5 252 200 R0101 0.25 –/–/– –/–/– – GJR5 251 800 R0101 0.1 –/–/– –/–/– – Input delay 7 ms, electrically isolated in groups of 8 Keypad controller for connection of operator panels with up to 32 keys / switches and 32 LEDs to the CS31 bus. Voltage supply 24 V DC, without housing. GJR5 252 700 R0101 0.1 Analog I/O modules series 90 Description: see „Overview of I/O modules“. Integrated CS31 field bus. AC: Channels can be individually configured as input or output. Type Number of AI / AO / AC 07 AI 91 8/–/– 07 DC 92 07 AC 91*) – / – / 16 Input signal Output signal Order code Price Weight p. piece kg ± 10V, 0 ... 20mA, ± 50 mV, ± 500 mV, ± 5 V, PT100, PT1000, thermocouple, 12 bits – GJR5 251 600 R0202 0.25 ± 10 V, 0 ... 20 mA, 4 ... 20 mA, 12 bits ± 10 V, 0 ... 20mA, 4 ... 20 mA, 12 bits GJR5 252 300 R0101 0.25 07_AI_91_perspektive *) Incl. 1 x DI for shut-off of all AOs of the module. With 2 modes of operation: (1) 8 AI and 8 AO with resolution of 12 bits or (2) in pairs as AI or AO with 8 bits. 07 AI 91 Communication modules series 90 Further networking interfaces for compact PLCs AC31 series 90. Connection to CPU via ribbon cable. Supply voltage 24 V DC. Type Protocol Software Interfaces Order code Price Weight p. piece kg 07 KP 90 RCOM Included 2 (1) RCOM (RS232/RS485); (2) RS232 for commissioning GJR5 251 000 R0303 0.45 07 KP 93 MODBUS Included 2 Modbus RTU, Master or Slave (RS232/RS485) GJR5 253 200 R1161 0.4 SST03598 ARCNET: Communication interfaces to PC For communication between ARCNET controllers and PC (programming, visualization). Type Description Order code SH FARC E3 K ARCNET-COAX interface card for ISA bus, without RS485, 1SAY 111 401 R0001 transfer rate 2.5 Mbps SH ARC PCI K ARCNET-COAX interface card for PCI bus, transfer rate 2.5 Mbps 07 KP 90 Price Weight p. piece kg 1SAY 111 402 R0001 SH ARC PCMCIA ARCNET-PCMCIA interface card (basic card) 1SAY 111 403 R0001 SH KOAX- PCMCIA COAX interface module for basic card 1SAY 111 404 R0001 6/30 1SDC007200C0202 0601_PLC.indd 30 17-11-2006 9:56:16 Automation Devices Small and Compact PLCs AC31 Ordering data - Accessories series 90, Programming pack. 907 AC1131 Accessories for series 90 Type Accessory for 07 SK 90 CPUs AC31 series 90 (KT94-S, KT95-KT98) 07 SK 92 07 MC 90 CPUs 07KT95 / 96 / 97 / 98 Description Order code Programming cable incl. adapter 25/9 poles. Cable length: 5 m GJR5 250 200 R0001 System cable for modem GJR5 250 400 R0001 Smart Media Card for data storage and user program backup, 8 MB GJR5 252 600 R0201 Lithium battery for data buffering GJR5 250 700 R0001 GJV3 073 915 R0001 07 LE 90 CPUs AC31 series 90 (07KT94-S, 07KT95, 07KT98) – RCOM coupler 07KP90 For commissioning interface. Adapter for programming cable 07SK90. – AC31-S: 07KP94-S Interface cable incl. adapter for KT94-S GJR5 250 300 R0001 with operator panel (passive mode) Price Weight p. piece kg Programming package 907 AC1131 (acc. to IEC61131-3) For small PLC AC31 series 40..50 (functionalities adjusted) and compact PLC AC31 series 90. Operating system: Windows 98 / NT / 2000 / XP. Description: See „Overview of Programming Packages“. Includes: 6 programming languages, sampling-trace, debugging, offline simulation, trace recording (multi-channel), recipe management, visualization, field bus configurators, online visualization package, etc. Scope of delivery: Software, libraries and documentation on CD-ROM, update service. Type Manual language Description Order code 907 AC 1131 German Programming package, version 5.0 GJP5 206 900 R0102 907 AC 1131 English Programming package, version 5.0 GJP5 207 000 R0102 Price Weight p. piece kg PLC’s Programming cable: See Accessories. Programming package AC31GRAF (based on IEC61131-3) For small PLC AC 31 series 40..50. Operating system: Windows 98 / NT / 2000 / XP. Description: See „Overview of Programming Packages“. Programming cable: See Accessories. Includes: 4 programming languages, debugging, visualization and many more. Can be used with previous PLCs of type 30 series and 07KR91 ... 07KT94. Scope of delivery: Software, libraries and documentation on CD-ROM. Type Manual language Description Order code AC31GRAF English Programming package 1SBS 260 250 R0101 AC31GRAF French Programming package 1SBS 260 250 R0101 AC31GRAF Italian Programming package 1SBS 260 250 R0101 Price Weight p. piece kg 907 AC1131 documentation Language German English Description CPUs AC31 series 90 (07KT94-S, 07KT95, 07KT98) Manuals for AC31 (as in software package 907 AC 1131). Complete hard- and software description, incl. CD-ROM containing documentation (4 ring binders) Order code Price 1SAC 133 947 R0101 1SAC 133 947 R0201 6/31 1SDC007200C0202 0601_PLC.indd 31 17-11-2006 9:56:58 Automation Devices Small and Compact PLCs AC31 Ordering data for Safety PLC AC31-S Safety PLC AC31-S, CPU SST02598 Description: see „Overview of CPUs“. Integrated AC31 safety field bus. For programming of safety-related functions and operating functions in one CPU. Integrated I/Os for operation signals (non safety-related). Decentrally expandable with I/O modules for operation signals and safety-related signals on the AC31 safety field bus. 07 KT 94-S Type Integrated digital I/Os (DI / DO / DC) Integrated analog I/Os (AI / AO) Counter inputs Program memory [kB] Order code Price Weight p. piece kg 07 KT 94-S 24 / 16 / 8 8/4 2 240 GJR5 252 100 R2101 1.3 07 KT 94-S *) ARCNET 24 / 16 / 8 8/4 2 240 GJR5 252 100 R2161 1.3 *) ARCNET integrated Safety I/O modules Decentral, internally redundant I/O modules, safety-related, voltage supply 24 V DC. Screw-type terminals. Integrated connection for AC31 safety field bus, electrically isolated against the bus. Digital I/Os DI / DO / AI Input signal Output signal Fault detection Order code 07 DI 90-S 8/–/– 24 V DC – Fault detection: Short circuit to 0 V and UP, wire break, prohibited input level range, passive faults, internal faults like bus disconnection. GJR5 250 900 R0202 0.25 07 DO 90-S –/8/– – 24 V DC / 0.5 A (T) Fault detection: Overload and/or short circuit to ZP, passive faults, internal faults. GJR5 250 800 R0202 0.25 07 AI 90-S –/–/4 4 ... 20 A – Fault detection: GJR5 251 200 R0202 Range over- or underrun, short circuit, wire break passive faults, internal faults. 0.25 SST03098 Type SST03198 07 DI 90-S Price Weight p. piece kg 07 DO 90-S Programming software for safety-related programming SST03798 For safety PLC AC 31-S. Operating system: MS-DOS. Programming cable: see accessories. The programming software consists of the packages 907 PC 33 + 907 PC 331 + 907 PC 339. Type Description 907 PC 33 General description of the programming interface. German Manual included. English GJP5 203 900 R0302 907 PC 331 Programming and test software. Programming languages: IL, FBD, LD. Scope of delivery: Programming software on floppy disc, manuals, update service. German GJP5 204 500 R0402 English GJP5 204 600 R0402 Add-on for safety-related functions for programming software 907 PC 331. For AC31-S safety CPU 07 KT94-S. Scope of delivery: Safety manual, software on floppy disc, update service. German GJP5 207 500 R0102 English GJP5 207 600 R0102 07 AI 90-S 907 PC 339 Manual language Order code Price Weight p. piece kg GJP5 204 000 R0302 6/32 1SDC007200C0202 0601_PLC.indd 32 17-11-2006 9:56:59 Automation Devices Further Accessories for Control Engineering Ordering data for Bus repeaters Bus repeater for CS31 field bus Voltage supply Description Order code Price Weight p. piece kg NCB 24 V DC Repeater for CS31 bus, max. length 2000 m (3 repeaters) FPR3 471 200 R1002 0.34 NCBR =24 V DC Repeater for CS31 bus, for redundant, ring- or star-shaped bus configuration FPR3 471 300 R1002 0.34 PLC’s Type 6/33 1SDC007200C0202 0601_PLC.indd 33 17-11-2006 9:57:26 Notes 6/34 1SDC007200C0202 0601_PLC.indd 34 17-11-2006 9:57:26 1SBC 49123 5F0304 1SBC 49118 5F0304 Displays and Operator Panels 1SBC 491 195 F0304 CP501 CP554 1SBC 49127 5F0304 1SBC 49125 5F0304 1SBC 49120 5F0304 CP551 CP555 CP502 PLC’s CP513 Man-machine communication The CP5xx operator panels ideally fulfill the requirements of automated processes for more transparency and efficiency: they create insight into the activities and the conditions of machines and installations and they allow for an intervention into the proceedings that happen there. To this end we offer an extensive line of operator panels, that ranges from the basic CP 501 for the display of text to devices that provide a graphics screen up to the touch-panel CP 555 with a color display. They communicate with the AC31 and AC500 controllers and have read and write access to the data of these controllers. The communication between operator panel and controller happens via the serial interfaces. When running complex applications, Ethernet or various other bus systems can also be used. identical for all devices. The function keys of most devices consist of switchable 2-color LEDs, marking stripes allow for the labeling and thus support the convenient operator guidance. The front cover of all devices offers protection class IP65. Depending on the type, the operator panels offer the following functions: Real-time clock Alarm management in numerous groups Trend curves and data logger Recipe management Report printing Password protection Flash memory up to 1600 kB The same software is used for all devices for fast and easy configuration. The commands and programming language are 6/35 1SDC007200C0202 0601_PLC.indd 35 17-11-2006 9:57:27 Displays and Operator Panels Display type Display Display size Display area W x H (mm) Text height (mm) 1SBC 491 265 F0304 1SBC 491 245 F0304 CP501 CP502 CP503 CP511 CP512 STN-LCD with backlight STN-LCD with backlight STN-LCD with backlight STN-LCD with backlight B/W-STN-LCD with backlight Text Text Text graphics and text graphics and text 240 x 64 pixels 240 x 128 pixels 2 lines x 16 characters 2 lines x 20 characters 4 lines x 20 characters 55.7 x 11.0 73.5 x 11.5 70.4 x 20.8 5.2“ 127.2 x 33.9 5.3“ 120.0 x 64.0 5 5 5 variable variable 5 (2 colors) 16 (2 colors) 16 (2 colors) 5 / 22 (with labels) 8 / 22 (with labels) 16 (8 with labeling strip) with ETTP card with ETTP card 1 group 4 groups 4 groups LEDs Function keys / other keys 1SBC 491 225 F0304 1SBC 491 205 F0304 1SBC 491 185 F0304 Overiew 4 3 / 20 Web functions Buzzer Alarm management Time channel Real-time clock real-time historical Trend curves Data logger Recipe management Report printing 8 levels 8 levels 8 levels 8 levels Password protection Multilanguage support Application memory 16 kB Flash 64 kB Flash 64 kB Flash 400 kB Flash 400 kB Flash Voltage supply 5 / 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 200 mA 150 mA 150 mA 450 mA 450 mA 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C RS232, RS422 RS232, RS422 Current consumption Ambient temperature Communication interfaces Expansion slot Degree of protection front cover Dimensions W x H x D (mm) Weight (kg) RS232 or RS422 RS232, RS422/RS485 RS232, RS422/RS485 (at the same time) (at the same time) – – – 1 1 IP65 IP65 IP65 IP65 IP65 104 x 69 x 38 142 x 90 x 47,5 147 x 163,5 x 38 211 x 198 x 69 214 x 232 x 87 0.2 0.5 0.7 1.5 1.4 6/36 1SDC007200C0202 0601_PLC.indd 36 17-11-2006 9:57:45 Displays and Operator Panels 1SBC 491 255 F0304 1SBC 491 235 F0304 1SBC 491 215 F0304 1SBC 491 195 F0304 1SBC 491 275 F0304 Overiew CP513 CP551 CP552 CP554 CP555 256 Colors LCD TFT with backlight Touch B/W STN with backlight Touch LCD 16 gray levels 256 Colors TFT touch display 256 Colors TFT touch display graphics and text graphics and text graphics and text graphics and text graphics and text 320 x 240 pixels 320 x 240 pixels 320 x 240 pixels 320 x 240 pixels 640 x 480 pixels 5.7“ 115.2 x 86.4 3.8“ 78.0 x 58.5 5.7“ 115.2 x 86.4 5.7“ 115.2 x 86.4 10.4“ 211.2 x 158.4 variable variable variable variable variable with ETTP card with ETTP card with ETTP card with ETTP card 16 groups 4 groups 5 groups 5 groups 11 groups historical historical historical historical historical 8 levels 8 levels 8 levels 8 levels 8 levels 400 kB Flash 400 kB Flash 400 kB Flash 400 kB Flash 1600 kB Flash 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 550 mA 450 mA 400 mA 450 mA 1A 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C 0 – 50 °C RS232, RS422 Ethernet RS232, RS422/RS485 RS232, RS422/RS485 RS232, RS422/RS485 RS232, RS422 2 – 1 1 2 IP65 IP65 IP65 IP65 IP65 276 x 198 x 89 138 x 100 x 30 200 x 150 x 69 200 x 150 x 69 290 x 250 x 105 1.7 0.6 1.5 1.5 3.3 16 (2 colors) PLC’s 16 (8 with labeling strip) 6/37 1SDC007200C0202 0601_PLC.indd 37 17-11-2006 9:57:53 Displays and Operator Panels Ordering data Operator panels with text display CP502 LCD display with backlight Voltage supply 24 V DC CP501: voltage supply 5 V DC, 24/5 V DC converter included in scope of delivery CP502/503: integrated real-time clock CP502/503: Recipe management CP502/503: Password protection in 8 levels CP502/503: Multilanguage support Type Lines Charact. per line Function LEDs keys / other keys Interfaces Order code CP501 2 16 4 RS232 or RS422 1SBP 260 170 R1001 0.2 CP502 2 20 3 / 20 RS232, RS422, RS485 1SBP 260 171 R1001 0.5 CP503 4 20 5 / 22 RS232, RS422, RS485 1SBP 260 172 R1001 0.7 5 Price Weight p. piece kg Operator panels with graphics display LCD display with backlight CP513 with 256 colors TFT display Voltage supply 24 V DC Graphics and text display Real-time clock Trend curves CP513: data logger Recipe management Password protection in 8 levels CK516 Management Multilanguage support Memory size 400 kB Type Pixels Function keys / LEDs other keys Interfaces Order code Price CP511 240 x 64 8 / 22 16 RS232, RS422 1SBP 260 173 R1001 1.5 CP512 240 x 128 16 / 22 16 RS232, RS422 1SBP 260 174 R1001 1.4 CP513 320 x 240 16 / 22 16 RS232, RS422 1SBP 260 175 R1001 1.7 CP511 Weight p. piece kg Operator panels with touch display CP555 LCD display with backlight CP554 and CP555 with 256 colors TFT display Voltage supply 24 V DC Graphics and text display Real-time clock Trend curves and data logger Recipe management Password protection in 8 levels CK516 Management Multilanguage support Memory size 400 kB (CP555: 1600 kB) Type Pixels Display Interfaces Order code Price Weight p. piece kg CP551 320 x 240 B/W - STN RS232, RS422, RS485 1SBP 260 176 R1001 1.4 CP552 320 x 240 B/W - STN RS232, RS422, RS485 1SBP 260 177 R1001 1.5 CP554 320 x 240 Color TFT RS232, RS422, RS485 1SBP 260 178 R1001 1.5 CP555 640 x 480 Color TFT RS232, RS422 1SBP 260 179 R1001 3.3 6/38 1SDC007200C0202 0601_PLC.indd 38 17-11-2006 9:57:58 Displays and Operator Panels Ordering data - Accessories Programming cables Type Interface Order code CAB5 RS232 1SBN 260 210 R1001 CAB6 RS232/RS422 converter 1SBN 260 211 R1001 Price Weight p. piece kg Price Weight p. piece kg Price Weight p. piece kg Price Weight p. piece kg Communication cables Type Controller Order code CAB45 Series 40 / 50 MiniDin 1SBN 260 213 R1001 CAB90 Series 90 1SBN 260 214 R1001 CAB57 Series AC500 SubD9 1SBN 260 215 R1001 CAB8 RS422/RS485 converter 1SBN 260 212 R1001 Programming software for operator panels CP5xx Applicable for all CP5xx operator panels, delivery on CD-ROM. Also includes documentation for all CP5xx operator panels. Description Order code CP500soft Software, documentation on CD 1SBS 260 283 R1001 Type Description Order code CK516 Add-on keyboard 1SBP 260 180 R1001 1SBN 260 320 R1001 PLC’s Type Accessories IFCPBDP Communication interface PROFIBUS DP IFCETTP Communication interface Ethernet 1SBN 260 322 R1001 IFC-PI Printer interface 1SBN 260 325 R1001 IFC-MC Interface for Smart Media Card (memory card not included) 1SBN 260 324 R1001 CK516 PCMCIA 4MB Memory card 4 MB 1SBN 260 326 R1001 PCMCIA 8MB Memory card 8 MB 1SBN 260 327 R1001 Protection sheet for CP551 Protection film for display CP551 (packing unit contains 5 pieces) 1SBN 260 330 R1001 Protection sheet for CP552 Protection film for display CP552 (packing unit contains 5 pieces) 1SBN 260 328 R1001 Protection sheet for CP554 Protection film for display CP554 (packing unit contains 5 pieces) 1SBN 260 331 R1001 Protection sheet for CP555 Protection film for display CP555 (packing unit contains 5 pieces) 1SBN 260 329 R1001 6/39 1SDC007200C0202 0601_PLC.indd 39 17-11-2006 9:57:59 Ask for our Main Catalogue P/N 1SNC 127 001 C0206 Ask for our iteractive CD P/N 1SNC 127 001 N0201 PLC’s prew PLC’s prewiring system 0602_Interfast.indb 40 17-11-2006 10:45:47 PLC´s prewiring system Contents Description ...................................................................................................................... 6/42 Ordering details .............................................................................................................. 6/44 Interfast Kits ................................................................................................................... 6/47 6/49 6/50 6/51 6/52 6/53 6/54 6/55 Interfast Interfast Interfast - Selection guide ABB - AC31 / S800 ...................................................................................................... Siemens - S7 300......................................................................................................... Télémécanique - TSX 37 / TSX 57 ................................................................................ Allen Bradley - SLC500 ................................................................................................ Allen Bradley - Control logix .......................................................................................... GE FANUC 90-30 / CEGELEC 80-35 ........................................................................... Télémécanique - Quantum ........................................................................................... s ew 6/41 1SDC007200C0202 0602_Interfast.indb 41 17-11-2006 10:45:54 PLC's prewiring system Interfast Interfast, ABB Entrelec's PLC wiring system, includes prewired and tested PLC plus 100's of interface assemblies to allow easier connection of your PLC to field and control equipment. Your PLC Interfast offers : - Prewired and pretested PLC cables mate with your PLC - Cable lengths upto 5 meters an higher - Reduce PLC wiring time from hours to minutes - Standard terminal blocks plus relay and optocoupler interfaces - Eliminate testing - Customize output - Operate in restricted space Simplify field wiring to all PLCs including : Swing arm prewired by ABB ABB Siemens Télémécanique AEG Cegelec GE Fanuc Allen Bradley Omron Mitsubishi A0P000 Choose among 100s of standard interface assemblies or customize your own. Install relays, optos, fuses, switches, and other plugs. Choose our plug-to-plug cable when your PLC is equipped with a connector on the I/O card. Save space : 5,08 mm (0.2") per PLC point. 6/42 1SDC007200C0202 0602_Interfast.indb 42 17-11-2006 10:45:54 Interfast, PLC wiring system Prewired and pretested PLC cable connections Eliminate testing and reduce your PLC wiring time from hours to minute. These prewired and pretested cables easily connect PLCs to control and field equipment. Typical cables consist of a PLC swing arm or connector on one end that plugs into the customer's PLC I/O board plus a connector on the other end which plugs into an ABB Entrelec interface module. Connection interfaces Ready-to-go preassembled modules for interfacing your PLC to control equipment. Select 8, 16 or 32 channel modules with single to four wire circuits. Interface modules available with features to enhance your design including fuses, switches, plugs, and test points. Available with screw clamp or spring connection. Interface to relay or optocoupler modules to provide circuit isolation and safety between your PLC and control or field equipment. Select from preassembled modules containing up to 16 relays or optocouplers. Screw clamp or spring connection. Pluggable and nonremovable relays, 1 SPDT, 2 SPDT, with fused output, 8, 12 and 16 relay output. Pluggable and nonremovable input and output optocouplers, 16 inputs and 16 outputs. Interfast Relay and optocoupler interfaces Universal interface for Interfast MS plugs For total customization, select an Interfast MS modular terminal block which accepts function plugs including strap, fuse, relay, input and output optocouplers, and more. Multipurpose connection cables A0P001 Prewired and pretested cables are terminated with selectable connector types or individual wires. Use for standard or custom connection to PLCs or other electronic equipment. Cable terminations include multiple individual wires, Omniconnect and Sub D connectors. 6/43 1SDC007200C0202 0602_Interfast.indb 43 17-11-2006 10:47:01 PLC's prewiring system Interfast Ordering detail Omniconnect Connection Interface Connection Interface without Led Type Single Wire 8 Channels (71 mm) 16 Channels (112 mm) 32 Channels (112 mm) 1SNA 621 016 R1100 1SNA 621 017 R1200 1SNA 631 001 R2500 Two Wire 1SNA 631 024 R1300 1SNA 631 025 R1400 Disconnect 1SNA 631 016 R1300 1SNA 631 017 R1400 Fused 1SNA 631 012 R1700 1SNA 631 013 R1000 Connection Interface with Led Omniconnect Connection Interface Type Single Wire 8 Channels (71 mm) 16 Channels (112 mm) 32 Channels (112 mm) 1SNA 621 018 R2300 1SNA 621 019 R2400 1SNA 631 003 R2700 Two Wire 1SNA 631 026 R1500 1SNA 631 027 R1600 Disconnect 1SNA 631 018 R2500 1SNA 631 019 R2600 Fused 1SNA 631 014 R1100 1SNA 631 015 R1200 Connection Interface without Led Type Two Wire 8 Channels (71 mm) 16 Channels (112 mm) Two/Three/four Wire 1SNA 631 054 R2100 1SNA 631 055 R2200 Disconnect Two/Three/four Wire 1SNA 631 082 R1600 1SNA 631 083 R1700 Fused Two/Three/four Wire 1SNA 631 098 R2600 1SNA 631 099 R2700 1SNA 631 031 R1200 Connection Interface with Led Omniconnect MS Interfaces Decoupling interface Type Two Wire 8 Channels (71 mm) 16 Channels (112 mm) Two/Three/four Wire 1SNA 631 052 R2700 1SNA 631 053 R2000 Disconnect Two/Three/four Wire 1SNA 631 080 R2000 1SNA 631 081 R1500 Fused Two/Three/four Wire 1SNA 631 096 R1400 1SNA 631 097 R1500 1SNA 631 029 R2000 Relay Terminal (1SPDT) - Decoupling Interface Type Commun négatif 8 relays (71 mm) 16 relays (112 mm) 1SNA 631 143 R2700 1SNA 631 125 R1500 Negative / Positive common 1SNA 631 182 R1700 Spare Relay Plug 1SNA 631 820 R1400 1SNA 631 820 R1400 1SNA 631 181 R1600 Optocoupler Terminal - Decoupling Interface Type Universal Interface 8 Optos (71 mm) 1SNA 631 177 R2100 * 16 Optos (112 mm) 1SNA 631 179 R0300 ** 5 VDC 24 VDC 48 VDC 125 VDC 24 VAC 48 VAC 115 VAC 230 VAC 1SNA 031 831 R0300 1SNA 031 800 R2100 1SNA 031 801 R1600 1SNA 031 845 R1100 1SNA 031 802 R1700 1SNA 031 803 R1000 1SNA 031 804 R1100 1SNA 031 805 R1200 1SNA 031 831 R0300 1SNA 031 800 R2100 1SNA 031 801 R1600 1SNA 031 845 R1100 1SNA 031 802 R1700 1SNA 031 803 R1000 1SNA 031 804 R1100 1SNA 031 805 R1200 Spare Output Opto plug 48 VDC / 100 mA 48 VDC / 1 A 24 VDC / 2 A 250 VAC / 700 mA 1SNA 031 810 R1200 1SNA 031 819 R1700 1SNA 031 815 R0300 1SNA 031 839 R1300 1SNA 031 810 R1200 1SNA 031 819 R1700 1SNA 031 815 R0300 1SNA 031 839 R1300 1SNA 031 829 R1500 1SNA 031 830 R1600 1SNA 031 829 R1500 1SNA 031 830 R1600 Spare Input Opto plug Spare Strap plug ST1 ST2 A01381 * 8 channels : For this interface, use up to 8 input plugs or up to 8 output plugs (always use 3 ST1 plugs and 1 ST2 plug). ** 16 channels : For this interface, use up to 16 input plugs or up to 16 output plugs (always use 2 ST1 plugs and 2 ST2 plugs). 6/44 1SDC007200C0202 0602_Interfast.indb 44 17-11-2006 10:47:09 PLC's prewiring system Interfast Ordering detail Omniconnect MS Interfaces Universal interfaces Universal Interface Without LED With LED Negative / Positive Common 1SNA 631 158 R0600 1SNA 631 178 R0200 Negative / Positive Common, Leds on supplies 1SNA 631 177 R2100 8 Channels (71 mm) 16 Channels (112 mm) Negative / Positive Common 1SNA 631 151 R2700 Negative / Positive Common, Leds on supplies 1SNA 631 179 R0300 1SNA 631 180 R2100 Input optocoupler plugs 125 VDC BNMS T125V-1 White 1SNA 031 831 R0300 24 VDC BNMS T24V-1 White 1SNA 031 800 R2100 48 VDC BNMS T48V-1 White 1SNA 031 801 R1600 5 VDC BNMS T5V-1 White 1SNA 031 845 R1100 24 VAC BNMS T24V-1 Yellow 1SNA 031 802 R1700 48 VAC BNMS T48V-1 Yellow 1SNA 031 803 R1000 115 VAC BNMS T115V-1 Yellow 1SNA 031 804 R1100 230 VAC BNMS T230V-1 Yellow 1SNA 031 805 R1200 24 VDC / 100 mA BNMS N24V-3 Red 1SNA 031 807 R1400 1SNA 031 807 R1400 24 VDC / 100 mA BNMS P24V-3 Red 1SNA 031 810 R1200 1SNA 031 810 R1200 24 VDC / 2 A BNMS N24V-1 Red 1SNA 031 813 R0100 1SNA 031 813 R0100 24 VDC / 2 A BNMS P24V-1 Red 1SNA 031 815 R0300 1SNA 031 815 R0300 24 VDC / 1 A BNMS N24V-2 Red 1SNA 031 817 R0500 1SNA 031 817 R0500 24 VDC / 1 A BNMS P24V-2 Red 1SNA 031 819 R1700 1SNA 031 819 R1700 24 VDC / 1 A BNMS A24V-4 Black 1SNA 031 839 R1300 1SNA 031 839 R1300 1 RT - 10 mA-6A/250 V BNMS N24V-1 Ivory 1SNA 031 820 R1400 1SNA 031 820 R1400 1 RT - 1 mA-6A/250 V BNMS N24V-2 Ivory 1SNA 031 847 R1300 1SNA 031 847 R1300 Interfast Out optocoupler plugs Relay plugs Output fuse plugs 125 V / 125 mA BNMS F125mA-1 Grey 1SNA 031 821 R0100 1SNA 031 821 R0100 125 V / 500 mA BNMS F500mA-1 Grey 1SNA 031 838 R1200 1SNA 031 838 R1200 125 V / 2 A BNMS F2A-1 Grey 1SNA 031 822 R0200 1SNA 031 822 R0200 125 V / 5 A BNMS F5A-1 Grey 1SNA 031 823 R0300 1SNA 031 823 R0300 BNMS F125mA-2 Grey 1SNA 031 824 R0400 1SNA 031 824 R0400 250 V / 2 A BNMS F2A-2 Grey 1SNA 031 825 R0500 1SNA 031 825 R0500 250 V / 5 A BNMS F5A-2 Grey 1SNA 031 826 R0600 1SNA 031 826 R0600 250 V / 125 mA Output fuse plugs 125 V / 125 mA BNMS F125mA-3 Grey 1SNA 031 827 R0700 1SNA 031 827 R0700 250 V / 125 mA BNMS F125mA-4 Grey 1SNA 031 828 R1000 1SNA 031 828 R1000 BNMS ST1 Grey 1SNA 031 829 R1100 1SNA 031 829 R1100 BNMS ST2 Grey 1SNA 031 830 R1600 1SNA 031 830 R1600 0-20 mA / 0-10 V BNMS CAI/U-500 Grey 1SNA 031 833 R0500 4-20 mA / 2-10 V BNMS CAI/U-500 Grey 1SNA 031 833 R0500 0-20 mA / 0-5 V BNMS CAI/U-250 Grey 1SNA 031 832 R0400 4-20 mA / 1-5 V BNMS CAI/U-250 Grey 1SNA 031 832 R0400 Strap plugs A01372 Converter plugs 6/45 1SDC007200C0202 0602_Interfast.indb 45 17-11-2006 10:47:26 PLC's prewiring system Interfast Ordering detail Omniconnect Connector Interface 8 channels Connection Interface without Led Type Single Wire 8 Channels 16 Channels 32 Channels 1SNA 021 024 R0300 1SNA 021 025 R0400 1SNA 021 021 R0000 1SNA 021 041 R1400 1SNA 021 098 R1600 Three Wire 1SNA 021 048 R2300 1SNA 021 049 R2400 1SNA 021 096 R0400 Disconnect (Single Wire) 1SNA 021 032 R0300 1SNA 021 033 R0400 1SNA 021 097 R0500 Fused (Three Wire) 1SNA 021 052 R1300 1SNA 021 053 R1000 Two Wire Connection Interface with Led 16 channels Type Single Wire 8 Channels 16 Channels 32 Channels 1SNA 021 026 R0500 1SNA 021 027 R0600 1SNA 021 023 R0200 1SNA 021 043 R1600 1SNA 021 093 R0100 1SNA 021 050 R2100 1SNA 021 051 R1600 1SNA 021 094 R0200 Disconnect (Single Wire) 1SNA 021 034 R0500 1SNA 021 035 R0600 1SNA 021 095 R0300 Fused (Three Wire) 1SNA 021 054 R1100 1SNA 021 055 R1200 Two Wire Three Wire 32 channels Omniconnect Decoupling interface 8 channels Connector Interface Type 16 channels 8 Relays 1 NO relay 24 VDC supply 1 SPDT relay 24 VDC supply 1 SPDT relay 24 VDC supply 16 Relays 1SNA 021 080 R1000 1SNA 021 084 R0000 1SNA 021 082 R0600 with fuse on common contact 1SNA 021 073 R1400 1SNA 020 927 R1400 1 DPDT relay 24 VDC supply 1SNA 021 074 R1500 1SNA 020 930 R2300 1 SPDT relay 24 VDC supply 1SNA 020 911 R1400 1SNA 020 929 R2600 with switch terminal 1 SPDT relay 24 VDC supply avec forçage bobine par switch 1 NO relay 1SNA 020 928 R2500 24 VDC supply for solenoïd valve control 1SNA 021 075 R1600 1SNA 020 931 R1000 A01368 Large range of interfaces available to suit any application. Please contact us. 6/46 1SDC007200C0202 0602_Interfast.indb 46 17-11-2006 10:47:33 Interfast, the prewiring system for PLC's Ordering details Interfast Kit Kit type A One harness length 1 or 2 meters and one connection interface 16 channels without led Spacing : 112 mm. Single-wire interface with terminal block assembly Kit 16 Input / Output 60 V max. Type Order P/N 1 meter Kit 100/BOM16/661 1SNA 631 183 R1000 2 meters Kit 200/BOM16/661 1SNA 631 184 R1100 Interfast Length Kit type B One harness length 1 or 2 meters and one decoupling interface with 16 pluggable relays 1 SPDT Spacing : 112 mm. 16 relays decoupling interface with terminal block assembly Kit 16 N relays 1 SPDT 6 A / 250 V Length Type Order P/N 1 meter Kit 100/BRI1621N/661 1SNA 631 185 R1200 2 meters Kit 200/BRI1621N/661 1SNA 631 186 R1300 Kit type C One harness length 1 or 2 meters and one decoupling interface with 16 no removable relays 1 NO Spacing : 170 mm. 16 relays decoupling interface A01375 Kit 16 N/P relays 1 NO 5 A / 250 V Length Type Order P/N 1 meter Kit 100/RIOM1621NP 1SNA 631 187 R1400 2 meters Kit 200/RIOM1621NP 1SNA 631 188 R2500 6/47 1SDC007200C0202 0602_Interfast.indb 47 17-11-2006 10:47:45 PLC's prewiring system Interfast Efficient wiring of Programmable Controllers The wiring of Programmable Controllers is made easy and error free with "INTERFAST" product. Available for most popular PLC’s, this technology offers the following features : - Compatible plug in I/O modules for PLC’s. - Prewired cables from 5 to 33 feet long terminated with keyed connectors. - Connector interfaces for easy wiring of field devices such as sensors. - Relay interfaces with contacts rated for 6 Amps / 250 Volts output. - Customized interfaces for analog circuits. - Opto isolator interfaces available. A01377 "INTERFAST" significantly reduces the cost of wiring and eliminates wiring errors. ABB : ALLEN BRADLEY : AC 31 S 800 Control Logix SLC 500 GE FANUC / CEGELEC : SIEMENS : 90-30 et 80-35 S7 200 S7 300 S7 400 OMRON : C 200 H MITSUBISHI : SCHNEIDER : TSX 37 MICRO TSX 57 PREMIUM TSX QUANTUM MELSEC A MELSEC AnS 6/48 1SDC007200C0202 0602_Interfast.indb 48 17-11-2006 10:47:52 INTERFAST - Selection guide ABB AC31 07 CR 41 - 24 VDC 07 CR 42 - 24 VDC 07 KR 51 - 24 VDC ICMK 14 F1 - 24 VDC ICMK 14 F1-M - 24 VDC 07 CR 41 - 120/230 V 07 CR 42 - 120/230 V 07 KR 51 - 120/230 V ICMK 14 F1 - 120/230 V ICMK 14 F1-M - 120/230 V 07 CT 41 - 24 VDC 07 CT 42 - 24 VDC 07 KT 51 - 24 VDC ICMK 14 N1 - 24 VDC ICMK 14 N1-M - 24 VDC Type 3 OR Possible connection interface Possible decoupling Interface 2 m Length cable Type , 8 optos 1SNA 036 912 R0100 2 6DO 1SNA 036 906 R1400 2 8DI 1SNA 036 912 R0100 2 6DO 1SNA 036 906 R1400 2 Channel types PLC Board Type 2 Type 1 Front adapter Possible Kit type Number of Kit necessary 8DI 8DI , 8 optos 1SNA 036 912 R0100 2 6DO , 8 optos / 8 relays N 1SNA 036 906 R1400 2 1-8 Channels , 8 optos 1SNA 036 918 R1700 2 9-16 Channels , 8 optos 1SNA 036 930 R1700 2 1-8 Channels , 8 optos / 8 relays N 1SNA 036 924 R0500 2 XI 16 E1 8 optos / 8 relays N 1SNA 036 930 R1700 2 XC 32 L1 32DIO ABC 2 , , , 16 optos / 16 relays N 1SNA 039 002 R2000 1 XC 32 L2 32DIO ABC 2 , , , 16 optos / 16 relays N 1SNA 039 002 R2000 1 9-16 Channels , 1-16 Channels , 16 optos / 16 relays N 1SNA 036 936 R0100 3 17-32 Channels , 16 optos / 16 relays N 1SNA 036 942 R1700 3 07 DC 92 ABB Type 1 Interfast XO 16 N1 Type 2 S800 PLC Board Channel types Front adapter Possible Kit type Number of Kit necessary Possible connection interface Possible decoupling Interface 2 m Length cable Type DI 801 16DI , 16 optos 1SNA 038 038 R2200 2 DI 810 / 830 16DI , 16 optos 1SNA 036 900 R2200 1 DI 811 / 831 16DI DI 814 16DI 1SNA 036 900 R2200 1 16 optos 1SNA 036 900 R2200 1 DO 801 16DO , 16 optos / 16 relays N 1SNA 038 038 R2200 2 DO 810 16DO , 16 optos / 16 relays N 1SNA 036 900 R2200 1 DO 814 16DO 1SNA 036 900 R2200 1 DI 802 / 803 / 820 / 821 8DI 1SNA 038 038 R2200 2 DI 885 8DI 1SNA 036 900 R2200 1 DO 802 / 815 / 820 / 821 8DO 1SNA 038 038 R2200 2 AI 801 8AI 1SNA 038 038 R2200 2 AI 810 / 830 / 835 8AI 1SNA 036 900 R2200 1 AO 801 8AO 1SNA 038 038 R2200 2 AO 810 8AO 1SNA 036 900 R2200 1 AI 820 4AO 1SNA 036 900 R2200 1 A01382 16 optos / 16 relays P 6/49 1SDC007200C0202 0602_Interfast.indb 49 17-11-2006 10:48:04 INTERFAST - Selection guide Type 2 Siemens Type 1 S7 300 OR Channel types Front adapter Possible Kit type Number of Kit necessary 32DI 1SNA 020 948 R0100 A 2 , , 6ES7321-1BL8x-0AA0 32DI 1SNA 020 948 R0100 A 2 , , 6ES7321-1EL0x-0AA0 32DI 6ES7322-1BL0x-0AA0 32DO 6ES7322-1EL0x-0AA0 32DO 6ES7323-1BL0x-0AA0 16DI / 16DO PLC Board 6ES7321-1BL0x-0AA0 Possible connection interface Possible decoupling Interface 2 m Length cable Type , 16 optos 1SNA 039 002 R2000 1 , 16 optos , 1SNA 020 948 R0100 1SNA 020 948 R0100 ABC ABC 2 2 , , , , , , 1SNA 039 002 R2000 1 1SNA 021 413 R0600 2 1SNA 039 002 R2000 1 1SNA 021 425 R0200 2 16 optos / 16 relays N 1SNA 039 002 R2000 1 16 optos / 16 relays N 6ES7321-1BH0x-0AA0 16DI , 16 optos 1SNA 021 419 R1400 2 6ES7321-1BH5x-0AA0 16DI , 16 optos 1SNA 021 419 R1400 2 , 1SNA 021 419 R1400 2 , 1SNA 039 002 R2000 1 6ES7321-1BH8x-0AA0 16DI 6ES7321-1CH0x-0AA0 16DI 6ES7321-1CH8x-0AA0 16DI 1SNA 021 425 R0200 2 6ES7321-1EH0x-0AA0 16DI 1SNA 021 425 R0200 2 6ES7321-1FH0x-0AA0 16DI 1SNA 021 425 R0200 2 6ES7321-7BH0x-0AB0 16DI 1SNA 021 425 R0200 2 1SNA 021 425 R0200 2 1SNA 021 425 R0200 2 1SNA 020 948 R0100 A 2 16DI 6ES7322-1BH0x-0AA0 16DO , 16 optos / 16 relays N 6ES7322-1BH8x-0AA0 16DO , 16 optos / 16 relays N 1SNA 021 425 R0200 2 6ES7322-1EH0x-0AA0 16DO 1SNA 021 425 R0200 2 6ES7322-1FH0x-0AA0 16DO 1SNA 021 425 R0200 2 6ES7322-1HH0x-0AA0 16DO 1SNA 021 425 R0200 2 6ES7322-5GH0x-0AB0 16DO 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7322-8BH0x-0AB0 16DO 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7322-1HF2x-0AA0 8DO 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7322-5HF0x-0AB0 8DO 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7331-1KF0x-0AB0 8AI 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7331-7KF0x-0AB0 8AI 1SNA 021 425 R0200 2 6ES7331-7NF0x-0AB0 8AI 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7331-7NF1x-0AB0 8AI 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7331-7PF0x-0AB0 8AI 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7332-5HF0x-0AB0 8AO 1SNA 020 948 R0100 A 2 , 1SNA 039 002 R2000 1 6ES7334-0CE00-0AA0 4AI / 2AO 1SNA 021 425 R0200 2 6ES7334-0KE00-0AB0 4AI / 2AO 1SNA 021 425 R0200 2 6ES7335-7HG0x-0AB0 4AI / 4AO 1SNA 021 425 R0200 2 6ES7332-5HD01-0AB0 4AO 1SNA 021 425 R0200 2 6ES7332-7ND01-0AB0 4AO 1SNA 021 425 R0200 2 6ES7313-6BE00-0AB0 CPU313 1SNA 020 948 R0100 ABC 2 , , , 16 optos / 16 relays N 1SNA 039 002 R2000 1 6ES7313-6CE00-0AB0 CPU313 1SNA 020 948 R0100 ABC 2 , , , 16 optos / 16 relays N 1SNA 039 002 R2000 1 6ES7313-5BE00-0AB0 CPU313 Complete offer in the Interfast catalogue 6ES7314-6BF00-0AB0 CPU314 Complete offer in the Interfast catalogue 6ES7314-6CF00-0AB0 CPU314 Complete offer in the Interfast catalogue A01383 6ES7321-7BH80-0AB0 6/50 1SDC007200C0202 0602_Interfast.indb 50 17-11-2006 10:48:15 INTERFAST - Selection guide Type 2 Télémécanique TSX 37 TSX DMZ 64 DTK Front adapter 32DI 32DO Possible Kit type A ABC Number of Kit necessary 2 2 Possible connection interface , , , , , , 2 m Length cable Type 16 optos 16 optos / 16 relays N 1SNA 039 002 R2000 1SNA 039 002 R2000 1 1 TSX DEZ 32D2 32DI , , , 16 optos 1SNA 021 905 R1400 2 TSX DSZ 32T2 32DO , , , 16 optos / 16 relays N 1SNA 021 905 R1400 2 TSX DSZ 32R5 32DO , , , 16 optos / 16 relays N 1SNA 029 967 R2100 2 16 optos 16 optos / 16 relays N 16 optos 16 relays N 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 021 905 R1400 1SNA 021 905 R1400 1SNA 021 905 R1400 1SNA 021 905 R1400 1SNA 021 899 R1600 1SNA 021 899 R1600 1 1 2 2 2 2 2 2 16 optos 1SNA 039 002 R2000 1 16 optos 1SNA 021 911 R0100 3 1SNA 039 002 R2000 1 16DI 12DO 16DI 16DO 16DI 12DO 16DI 12DO A ABC TSX DEZ 12D2K 12DI A TSX DEZ 12D2 12DI TSX DMZ 28 DTK TSX DMZ 28 AR TSX DMZ 28 DR TSX DMZ 28 DT TSX DMZ 16DTK 8DI / 8DO TSX DSZ 08 T2K 8DO TSX AEZ 801 , , , , 1 1 , , , A , , , , 16 optos , , , 1 1 1SNA 028 505 R2200 1 8AI 1SNA 036 439 R1700 3 TSX AEZ 802 8AI 1SNA 036 439 R1700 3 TSX AMZ 600 4AI / 2AO 1SNA 036 439 R1700 3 TSX AEZ 414 4AI 1SNA 036 451 R1300 3 TSX ASZ 401 4AO 1SNA 036 451 R1300 3 TSX ASZ 200 2AO 1SNA 036 451 R1300 3 , Télémécanique PLC Board TSX DEY 64 D2K TSX DSY 64 T2K TSX DEY 32 D2K TSX DEY 32 D3K TSX DSY 32 T2K TSX DMY 28 FK TSX DMY 28 RFK TSX DEY 16FK TSX DEY 16D2 TSX DEY 16D3 TSX DEY 16A2 TSX DEY 16A3 TSX DEY 16A4 TSX DEY 16A5 TSX DSY 16T2 TSX DSY 16T3 TSX DSY 16R5 TSX DSY 16S4 TSX DSY 16S5 TSX AEY 1614 TSX AEY 1600 Tension TSX AEY 1600 Courant TSX AEY 800 Tension TSX AEY 800 Courant TSX AEY 810 Tension TSX AEY 810 Courant 8 optos / 8 relays N Type 1 TSX 57 A01384 Possible decoupling Interface Type 2 Type 3 Interfast OR Channel types PLC Board Type 3 Type 1 OR Channel types 64DI 64DO 32DI 32DI 32DO 16DI 12DO 16DI 12DO 16DI 16DI 16DI 16DI 16DI 16DI 16DI 16DO 16DO 16DO 16DO 16DO 16AI 16AI 16AI 8AI 8AI 8AI 8AI Front adapter Possible Kit type A ABC A A ABC A ABC A ABC A Number of Kit necessary 4 4 2 2 2 1 1 1 1 1 Possible connection interface , , , , , , , , , , , , , , , , , , , , , , , Possible decoupling Interface 16 optos 16 optos / 16 relays N 16 optos 16 optos / 16 relays N 16 optos 16 relays N 16 optos 16 relays N 16 optos 16 optos , , 16 optos / 16 relays N 16 optos / 16 relays N 2 m Length cable Type 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 039 002 R2000 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 637 R1300 1SNA 026 649 R0700 1SNA 026 649 R0700 1SNA 026 649 R0700 1SNA 036 575 R1700 1SNA 036 621 R1500 1SNA 036 569 R2100 1SNA 036 621 R1500 1SNA 036 569 R2100 1SNA 036 621 R1500 1SNA 036 569 R2100 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 6/51 1SDC007200C0202 0602_Interfast.indb 51 17-11-2006 10:48:26 INTERFAST - Selection guide Allen Bradley Type 4 Type 1 Type 3 SLC500 OR PLC Board Channel types 1746-IB32 32DI Front adapter Possible Kit type Number of Kit necessary Type 2 Possible connection interface , , Possible decoupling Interface 2 m Length cable Type , 16 optos 1SNA 028 031 R1100 4 1746-IV32 32DI 16 optos 1SNA 028 031 R1100 4 1746-OB32 32DO , , , 16 optos / 16 relays N 1SNA 028 025 R1300 4 1746-OB32E 32DO , , , 16 optos / 16 relays N 1SNA 028 025 R1300 4 1746-OV32 32DO 16 optos / 16 relays P 1SNA 028 025 R1300 4 1746-IA16 16DI 1SNA 021 611 R1400 2 1746-IB16 16DI 1SNA 020 949 R0200 A 1 1746-IG16 16DI 1SNA 020 950 R0700 A 1 1746-IM16 16DI 1746-IN16 16DI 1SNA 020 949 R0200 A 1 , 1746-IV16 16DI 1SNA 020 949 R0200 A 1 , 1746-ITV16 16DI 1SNA 020 949 R0200 A 1 , 1746-ITB16 16DI 1SNA 020 949 R0200 A 1 , 1746-OA16 16DO 1746-OB16 16DO 1SNA 020 950 R0700 ABC 1 , 1747-OB16E 16DO 1SNA 020 950 R0700 ABC 1 , 1748-OBP16 16DO 1SNA 020 950 R0700 ABC 1 , 16 optos / 16 relays N 1746-OG16 16DO 1SNA 020 950 R0700 A 1 1746-OV16 16DO 1SNA 020 950 R0700 AC 1 1747-OV16P 16DO 1SNA 020 950 R0700 AC 1 1746-OW16 16DO , , 1SNA 020 949 R0200 1SNA 039 002 R2000 1 1SNA 039 002 R2000 1 1SNA 021 611 R1400 2 1SNA 039 002 R2000 1 1SNA 039 002 R2000 1 16 optos 1SNA 039 002 R2000 1 16 optos 1SNA 039 002 R2000 1 1SNA 021 635 R1400 2 16 optos / 16 relays N 1SNA 039 002 R2000 1 16 optos / 16 relays N 1SNA 039 002 R2000 1 16 optos 1SNA 039 002 R2000 1 1SNA 039 002 R2000 1 16 optos / 16 relays P 1SNA 039 002 R2000 1 16 optos / 16 relays P 1SNA 039 002 R2000 1 16 optos / 16 relays N 1SNA 021 641 R2200 2 1SNA 039 002 R2000 1 8AI 1746-NI4 4AI 1SNA 036 007 R1200 3 1746-NR4 4AI 1SNA 036 844 R1500 2 1746-NO4I 4AO 1SNA 036 013 R0700 3 4AO 1SNA 036 013 R0700 3 A01385 1 16 optos 1746-NI8 1746-NO4V A , 6/52 1SDC007200C0202 0602_Interfast.indb 52 17-11-2006 10:48:43 INTERFAST - Selection guide Type 1 Allen Bradley Type 2 Possible connection interface Channel types 1756-IB32 32DI , , , 1756-IV32 32DI , , 1756-OB32 32DO , , 1757-OV32E 32DO , , 1SNA 029 727 R2000 1 1756-IA16I 16DI , 1SNA 029 739 R0400 1 1756-IB16I 16DI , 1SNA 029 739 R0400 1 1756-IH16I 16DI , 1SNA 029 739 R0400 1 1756-IM16I 16DI , 1SNA 029 739 R0400 1 2 Front adapter Possible Kit type Number of Kit necessary PLC Board Possible decoupling Interface 2 m Length cable Type 16 optos 1SNA 029 733 R2600 1 , 16 optos 1SNA 029 733 R2600 1 , 16 optos / 16 relays N 1SNA 029 727 R2000 1 , 16 optos / 16 relays N 1756-IB16D 16DI 1SNA 029 757 R0600 1756-IA16 16DI 1SNA 029 799 R0100 2 1756-IB16 16DI 1SNA 029 799 R0100 2 , 16 optos 1756-IC16 16DI 1SNA 029 799 R0100 2 1756-IN16 16DI 1SNA 029 799 R0100 2 1756-IV16 16DI , 1SNA 029 799 R0100 2 1756-OA16I 16DO , 1SNA 029 739 R0400 1 1756-OB16I 16DO , 1SNA 029 739 R0400 1 1756-OB16IS 16DO , 1SNA 029 739 R0400 1 1756-ON16I 16DO , 1SNA 029 739 R0400 1 1756-OB16D 16DO , 16 optos / 16 relays N 1SNA 029 745 R0200 2 1SNA 029 793 R2300 2 16 optos / 16 relays N 1756-OA16 16DO 1756-OB16E 16DO , 1756-OW16I 16DO , 1756-OV16E 16DO 1756-IF16 16AI 1756-IF8 1756-OF8 1756-IF6I 16 optos 1SNA 029 793 R2300 2 1SNA 029 739 R0400 1 1SNA 029 793 R2300 2 1SNA 036 061 R1700 1 8AI 1SNA 036 067 R1500 2 8AO 1SNA 036 043 R1500 2 6AI 1SNA 036 055 R1100 2 1756-IR6I 6AI 1SNA 036 055 R1100 2 1756-IF6CIS 6AI 1SNA 036 055 R1100 2 1756-OF6CI 6AO 1SNA 036 055 R1100 2 1756-OF6VI 6AO 1SNA 036 055 R1100 2 A01386 16 optos / 16 relays NP Interfast Control Logix 6/53 1SDC007200C0202 0602_Interfast.indb 53 17-11-2006 10:48:54 INTERFAST - Selection guide Type 2 GE FANUC 90-30 CEGELEC 80-35 PLC Board IC 693 MDL 654 Channel types Type 1 Front adapter Possible Kit type Number of Kit necessary Possible connection interface Possible decoupling Interface 32DI IC 693 MDL 655 32DI IC 693 MDL 752 32DO IC 693 MDL 753 32DO , , , , , , , 2 m Length cable Type 1SNA 028 133 R1400 1 16 optos 1SNA 028 145 R2000 1 16 optos / 16 relays NP 1SNA 028 139 R2200 1 16 optos / 16 relays N 1SNA 028 145 R2000 1 IC 693 MDL 240 16DI 1SNA 026 073 R1100 2 IC 693 MDL 241 16DI 1SNA 026 079 R2700 2 IC 693 MDL 645 / 646 16DI 1SNA 026 079 R2700 2 IC 693 MDL 340 16DO 1SNA 026 097 R0200 2 IC 693 MDL 740 / 742 16DO 16 optos / 16 relays N 1SNA 026 091 R0400 2 16 optos / 16 relays NP , 16DO 1SNA 026 091 R0400 2 16DO 1SNA 029 555 R2400 2 IC 693 MDR 390 8DI 8DO 1SNA 026 091 R0400 2 IC 693 MDL 310 12DO 1SNA 026 097 R0200 2 IC 693 ALG 222 / 223 16AI 1SNA 036 625 R1100 2 HE 693 RTD 6XX 6AI 1SNA 026 091 R0400 2 IC 693 ALG 392 16AO 1SNA 026 079 R2700 2 IC 693 ALG 442 4AI 2AO 1SNA 026 091 R0400 2 HE 693 ADC 405 4AI 1SNA 036 121 R0000 2 HE 693 ADC 410 4AI 1SNA 036 121 R0000 2 HE 693 ADC 415 4AI 1SNA 036 121 R0000 2 HE 693 ADC 420 4AI 1SNA 036 121 R0000 2 IC 693 ALG 220 4AI 1SNA 026 091 R0400 2 IC 693 ALG 221 4AI 1SNA 026 091 R0400 2 HE 693 DAC 410 4AO 1SNA 036 121 R0000 2 A01387 IC 693 MDL 741 IC 693 MDL 940 6/54 1SDC007200C0202 0602_Interfast.indb 54 17-11-2006 10:49:05 INTERFAST - Selection guide Type 2 Télémécanique Quantum OR Channel types Front adapter Possible Kit type Number of Kit necessary Possible connection interface Possible decoupling Interface 2 m Length cable Type 1SNA 039 002 R2000 1 140 DDI 36400 96DI A 6 , , , 16 optos 140 DDO 36400 96DO ABC 6 , , , 16 optos / 16 relays N 140 DAI 55300 32DI 140 DDI 35300 32DI , , , 140 DDI 85300 32DI , , , 140 DDI 15310 32DI 140 DAI 35300 140 DAI 45300 1SNA 039 002 R2000 1 1SNA 021 527 R0000 2 16 optos 1SNA 021 527 R0000 2 16 optos 1SNA 021 527 R0000 2 , 1SNA 021 527 R0000 2 32DI , 1SNA 021 527 R0000 2 32DI , 1SNA 021 527 R0000 2 , 1SNA 021 527 R0000 2 1SNA 021 527 R0000 2 1SNA 021 527 R0000 2 , , , 16 optos 140 DDI 35310 32DI 140 DAI 75300 32DI 140 DSI 35300 32DI , , , 16 optos 140 DDO 35300 32DO , , , 16 optos / 16 relays N 1SNA 021 527 R0000 2 140 DDO 35310 32DO , , , 16 optos / 16 relays P 1SNA 021 527 R0000 2 140 DAO 85300 32DO 1SNA 021 527 R0000 2 1SNA 021 527 R0000 2 1SNA 021 527 R0000 2 140 DDO 15310 32DO 140 DVO 85300 32DO , , , , , , 16 optos / 16 relays N 16DI , 1SNA 021 527 R0000 2 16DI , 1SNA 021 527 R0000 2 140 DDI 84100 16DI , 1SNA 021 527 R0000 2 140 DAI 54300 16DI 1SNA 021 539 R1400 3 140 DAI 34000 16DI , 1SNA 021 527 R0000 2 140 DAI 44000 16DI , 1SNA 021 527 R0000 2 140 DAO 84000 16DO , 1SNA 021 527 R0000 2 140 DRA 84000 16DO , 1SNA 021 527 R0000 2 140 DAO 84010 16DO , 1SNA 021 527 R0000 2 140 DDO 84300 16DO , 16 optos / 16 relays N 1SNA 021 539 R1400 3 140 DDO 88500 12DO , 16 optos / 16 relays NP 1SNA 029 667 R0400 3 140 DRC 83000 8DO , 1SNA 021 545 R1200 2 140 ACI 04000 16AI , 1SNA 021 527 R0000 2 140 ARI 03000 8AI 1SNA 036 541 R1500 2 140 ARI 03010 8AI 1SNA 036 541 R1500 2 140 AMM 09000 4AI 2AO 1SNA 038 021 R1100 3 140 ACO 02000 4AO 1SNA 036 529 R1100 3 140 AVO 02000 4AO 1SNA 036 541 R1500 2 A01388 140 DAI 54000 140 DAI 74000 Interfast PLC Board Type 3 Type 1 6/55 1SDC007200C0202 0602_Interfast.indb 55 17-11-2006 10:49:11 FBP F FBP FieldBusPlug 0603_FBP.indd 56 1-12-2006 15:18:09 FBP FieldBusPlug Communicative Switching and Automation components Contents FieldBusPlug System Description ........................................................................................................ 6/58 Overview.......................................................................................................................... Fields of application for FBP terminal devices ............................................................... FBP terminal device data .............................................................................................. Device data .................................................................................................................. 6/60 6/60 6/61 6/64 Dimensional drawings.................................................................................................... 6/65 Ordering data - Communicative motor starters .......................................................... Motor Starter Direct MSD11-FBP ................................................................................. Motor Starter Reverse MSR22-FBP .............................................................................. Motor starter Fieldbus Interface MFI21-FBP ................................................................. Universal Motor Controller UMC22-FBP ....................................................................... 6/67 6/67 6/67 6/68 6/68 Ordering data - FieldBusPlug connectors and accessories ...................................... AS Interface ................................................................................................................. PROFIBUS DP-V0 / DP-V1 .......................................................................................... DeviceNet, MODBUS-RTU .......................................................................................... 6/71 6/71 6/73 6/75 FBP Overview - Further FBP terminal devices .................................................................... 6/70 Ordering data - System accessories and documentation .......................................... 6/77 F 6/57 1SDC007200C0202 0603_FBP.indd 57 1-12-2006 15:18:33 FBP FieldBusPlug B11_3282 System description General information The FBP system connects switching devices and other similar components via any fieldbus types with usual automation systems (PLCs) in a simple and cost-efficient way. The switching devices are independent of the chosen fieldbus type. Connection to the various fieldbus types is established via the fieldbus- One device for all field bus types Each device, and each function module within the product familiy, has a fieldbus-neutral interface. A specially prefabricated connection cable establishes the communications connections with its bus-specific plug interface. In this way, flexibility, transparency and reliability in the process are achieved. The connecting, operating and diagnostic elements are placed at the front of all devices providing increased ease of installation. Process monitoring/control Process monitoring/control Control system (any) FBP devices (fieldbus-neutral) B12_3282 all standard The components 2CDC 341 084 F0b06 The FieldBusPlug cable is used inside as well as outside of the control cabinet. Particularly for usage outside of the control cabinet the FBP cable complies with IP65, being at the same time a small and robust device excellently suitable for industrial usage. One of the outstanding advantages is the presence of the 24 V DC supply voltage inside the FBP cable which makes additional wiring unnecessary because the available current is sufficient for most applications. Examples of typical devices for connection are sensors, push-buttons/switches, signal lamps, motor contactors, motor branch connections, etc. The FieldBusPlug connects The FieldBusPlug provides a name to the new product family as a connecting element. The various FieldBusPlugs can be used with different fieldbus types. The definitions of the respective fieldbus standards apply. 6/58 1SDC007200C0202 0603_FBP.indd 58 1-12-2006 15:18:34 FBP FieldBusPlug System description General information The FieldBusPlug system, with its new installation concept, opens a multitude of further possibilities for centralized and decentralized applications. Simple integration into the process, the compact and spacesaving designs of the devices, the flexibility during planning and designing as well as the cost-effective assembly and commissioning are further application-specific features. This offers considerably effects for Shorter throughput and realization times Until now, wiring and cabling has been expensive and time-consuming in machines and plants. Standardized plug-in fieldbus connections now provide fast installation and the highest level of flexibility. Higher quality in machines and plants Prefabricated devices, plug-in technology and less wiring expenditure reduce failures. Standards make general planning and project planning more reliable, the assembly more effective and reduce the commissioning time. Smaller control cabinets The FBP product range includes particularly compact device versions. The products provide a high level of functionality in minimal space. For example, the small dimensions of the only 45 mm wide reverse motor starter MSR22-FBP makes additional space in the control cabinet. Improved response time FBP Reacting flexibly to customer requirements means being able to carry out modifications even shortly before completion. All devices can be replaced in a minimum of time. Due to the devices’ independence of the fieldbus type, the determination of the field bus system can be made just before the control cabinet is to be delivered. Effortless connection to the process The FBP system also shows its high adaptability when inserted into the automation level and thus into the process. With the aid of standardized software functions, the FBP components and automation devices can be integrated into the process via standard fieldbusses. Via the fieldbus, all device information are transmitted to the automation level and thus can be visualized in the entire process. Which data are forwarded depends on the performance data of the chosen fieldbus system. Increased availability of machines and plants Process monitoring/control Control system (any) The FBP components have extensive diagnostic functions. For example, the status of each FBP device and fieldbus plug as well as of the bus is indicated by LEDs. Depending on the functionality of the device, a preventive diagnostic function enables preventive maintenance (e.g. by counting the number of switching cycles) and operating data of the motor can be displayed on an operating panel. This allows possible malfunctions to be recognized before downtimes and production failures occur. An occurring error can be visualized thanks to the communication ability of the components and can therefore be remedied faster. all standard FBP-devices (fieldbus-neutral) field bus types Field level 6/59 1SDC007200C0202 0603_FBP.indd 59 1-12-2006 15:18:35 FBP FieldBusPlug Fields of application for FBP terminal devices Overview 왖 쐍 쐍 쐍 쐍 쐍 쐍 2CDC 341 084 F0b06 Function UMC22-FBP Integrated motor control functions Integrated digital inputs and outputs Adjustable trip categories Adjustable change-over times Storage of the device data settings Preventive diagnostic function MFI21-FBP MSD11-FBP and MSR22-FBP 쐍 쐍 쐍 쐍 쐍 B12_3282 Side-mountable to motor protecting switch MS325 Integrated motor control functions Integrated digital inputs and outputs Digital input for direct acquisition of the MS325 switch position Adjustable change-over times Preventive diagnostic function B11_3282 쐍 쐍 쐍 쐍 쐍 쐍 Direct or reverse operation Integrated line protection Ready-made complete device Compact space-saving design Direct PE connection to the motor connector 쐍 Device replacement without removal of the comb-shaped bar 왖 12 A 63 A PDP22-FBP (PROFIBUS PDQ22-FBP (PROFIBUS DNP21-FBP (DeviceNet) MRP21-FBP (MODBUS RTU) x x x x x x x x MSR21-FBP UMC22-FBP ASD11-FBP (AS-Interface) ASP22-FBP 1)) (AS-Interface) x x MSR22-FBP Device functions Rated motor current Terminal device functions completely usable with FieldBusPlug ... FieldBusPlug terminal devices MSD11-FBP Applicability of device functions depending on the fieldbus system performance 25 A x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Integrated motor control functions Direct starting Reverse starting x Servo-drive Star-delta starting Actuator Transparent mode x For detailed technical information please refer to the FieldBusPlug system documentation (see end of this chapter) 6/60 1SDC007200C0202 0603_FBP.indd 60 1-12-2006 15:18:36 FBP FieldBusPlug FBP Terminal Device Data Overview Communicative motor starters - compact devices Motor Starter Direct MSD11-FBP B11_3282 Dimensions Mounting Nominal current ranges Applicability Short-circuit capacity ICS Switching frequency (motor starting) Contactor Contact rating Contact lifetime Integrated diagnostic functions FBP Motor Starter Direct Optional Degree of protection Power feeding Operating voltage Vi Control voltage feeding External attachment plug Control voltage Motor connection Conductor cross section Motor protection Conductor cross section 45 x 260 x 120 (138) mm DIN rail, on 1 or 2 rails as desired (spacing 125 mm), usage of 2 rails increases vibration resistance Woehner conductor rail system adapter, Rittal, Germany IP 20 Comb-shaped rail or cable 400 V AC, 50 and 60 Hz, three-phase current Simplest feeding via bus connector; switchable to ext. feeding 1.5 mm2 max. (supplied on delivery) 24 V DC (+ 30%, - 20%) Plug-in conn. on front-side (plug supplied on del.) L1, L2, L3, PE 2.5 mm2 max. Integr. motor protecting switch MS116 (overload, short-circuit) 2 x 1...4 mm2 (single- or multiple-wire) 2 x 0.75...2.5 mm2 (fine-wire with wire-end ferrules) 11 0.1...12 A 50 kA (0.1 - 6.3 A), 12.5 kA (6.3 - 10 A), 10 kA (10 - 12 A) max. 15 starts per hour max. 60 starts per hour at 40 % duty ratio and tstarting = 1 s Integrated contactor B7 12 A max., AC-3, 400 V AC 700,000 switching cycles at 12 A, AC-3 LED for control voltage LED for contactor switch position LED for motor protection Motor Starter Reverse MSR22-FBP Dimensions Mounting Optional Degree of protection Power feeding Operating voltage Vi Control voltage feeding External attachment plug Control voltage Motor connection Conductor cross section Motor protection Conductor cross section Motor Starter Reverse Nominal current ranges Applicability Short-circuit capacity ICS Switching frequency (motor starting) Contactor Contact rating Contact lifetime Integrated diagnostic functions 45 x 260 x 120 (150) mm DIN rail, on 1 or 2 rails as desired (spacing 125 mm), usage of 2 rails increases vibration resistance Woehner conductor rail system adapter, Rittal, Germany IP 20 Comb-shaped rail or cable 400 V AC, 50 and 60 Hz, three-phase current Simplest feeding via bus connector; switchable to ext. feeding 1.5 mm2 max. (supplied on delivery) 24 V DC (+ 30%, - 20%) Plug-in conn. on front-side (plug supplied on del.) L1, L2, L3, PE 2.5 mm2 max. Integr. motor protecting switch MS116 (overload, short-circuit) 2 x 1...4 mm2 (single- or multiple-wire) 2 x 0.75...2.5 mm2 (fine-wire with wire-end ferrules) 11 0.1...12 A 50 kA (0.1 - 6.3 A), 12.5 kA (6.3 - 10 A), 10 kA (10 - 12 A) max. 15 starts per hour max. 60 starts per hour at 40 % duty ratio and tstarting = 1 s Integrated contactor 2 x B7 12 A max., AC-3, 400 V AC 700,000 switching cycles at 12 A, AC-3 LED for control voltage LED for contactors switch positions LED for motor protection 6/61 1SDC007200C0202 0603_FBP.indd 61 1-12-2006 15:18:38 FBP FieldBusPlug FBP Terminal Device Data Overview Communicative motor starters with control functions B12_3282 Motor Starter Fieldbus Interface MFI21-FBP Dimensions 36 (90) x 90 x 70 mm Mounting DIN rail Mechanical coupling to motor protecting switch MS 325 Degree of protection IP 20 Power feeding see MS 325 Control voltage feeding Motor starter Fieldbus Interface simplest feeding via bus connector; switchable to ext. feeding Connection max. 1.5 mm2 Control voltage 24 V DC (+ 30%, - 20%) Motor connection see MS 325 Conductor cross section terminals max. 1 x 2.5 mm2 or max. 2 x 1.5 mm2 Integrated inputs 3 digital inputs 24 V DC 1 digital input, mechanically coupled with MS325 switch position Integrated outputs 3 relay outputs with common supply Voltage switching capacity 24 V AC/DC ... 250 V AC/DC Current switching cap. per relay 240 V AC (AC 15) 120 V AC (AC 15) 250 V DC (DC 13) 24 V DC (DC 13) max. 1.5 A max. 3 A max. 0.11 A max. 1 A Load current via common Imax = 3 A (thermal limit) Relay contact lifetime > 5 x 106 switching cycles - mechanical lifetime > 1 x 106 switching cycles - at 230 V AC, 0.5 A Protective circuits with inductive loads for direct current free-wheeling diodes, for alternating current varistors / VDRs Integrated control functions Direct starting, reverse starting, star-delta starting, transparent mode (not for AS-Interface) Diagnosis at the device LED - Internal supply voltage LED - Device error LED - Status of the digital inputs and outputs Contactor switching cycles count and data transmission to the automation device (not for AS-Interface) Note: 6/62 1SDC007200C0202 0603_FBP.indd 62 1-12-2006 15:18:39 FBP FieldBusPlug FBP Terminal Device Data Overview Communicative motor starters with control functions 2CDC 341 084 F0b06 Universal Motor Controller UMC22-FBP Dimensions 70 x 105 x 87,5 (110) mm Mounting On DIN rail or with screws (4 screws M4) Degree of protection IP 20 Power feeding Bar-type current transf. max. 25 mm2 (max. diameter. = 11 mm) Operating voltage Ue 690 V AC, 50 and 60 Hz, 3-phase AC Nominal motor current 0.24 ... 63 A with protective current transformers up to 850 A Short-circuit protection By fuse on mains side Control voltage feeding Universal Motor Controller Simplest feeding via bus connector; switchable to ext. feeding Connection max. 1.5 mm2 Control voltage 24 V DC (+30%, -20%) Conductor cross section terminals max. 1 x 2.5 mm2 or max. 2 x 1.5 mm2 Integrated inputs 6 digital inputs 24 V DC 1 PTC input Integrated outputs 3 relay outputs with common supply Voltage switching capacity 24 V AC/DC ... 250 V AC/DC Current switching cap. per relay max. 1.5 A 120 V AC (AC15) max. 3 A 250 V DC (DC13) max. 0.11 A 24 V DC (DC13) max. 1 A Load current via common Imax = 4 A (thermal limit) Relay contact lifetime > 5 x 106 switching cycles - mechanical lifetime FBP 240 V AC (AC15) > 1 x 106 switching cycles - at 230 V AC, 0.5 A Protective circuits with inductive loads For direct current free-wheeling diodes, for alternating current varistors / VDRs Integrated control functions Direct starting, reverse starting, star-delta-starting, servo-drive, actuator, transparent mode (not for AS-Interface), emergency start function, stand alone operation (operation also without bus connection) Integrated motor protection functions Adjustment of starting and change-over times via Control Panel Error acknowledgement via Control Panel or bus Selectable disabling of outputs on error (PLC or bus) Overload monitoring / phase failure detection Detection of blocking motors Integrated storage of parameters and motor data Integrated diagnostic functions LED for control voltage LED for "motor running" LED for "fault indication" Contactor switching cycles count and data transmission to automation device (not for AS-Interface) Optional Control Panel For adjustment and visualization of motor and device data as well as of bus parameters 6/63 1SDC007200C0202 0603_FBP.indd 63 1-12-2006 15:18:40 FBP FieldBusPlug Device data Overview x LED switch pos. motor protection x DNP21-FBP MRP21-FBP x PDP22-FBP PDQ22-FBP LED switch pos. contactor(s) ASP22-FBP x ASD11-FBP MSR21-FBP x UMC22-FBP MSR22-FBP x Functions and technical data Full usability of terminal device functions with FieldBusPlug ... FieldBusPlug terminal devices MSD11-FBP FieldBusPlug terminal devices FieldBusPlug bus connectors x x x x Remarks For detailed technical information please refer to the FieldBusPlug system documentation Integrated diagnostic functions LED supply voltage x LED ready to operation yellow x x x D/B x x x red x x red x LED motor running yellow x LED for states of digital I/Os Bus info contactors green yellow LED bus failure LED function failure x green x x yellow x x x x x Information to PLC x x Information to PLC x x x Information to PLC x x x Information to PLC x Bus info motor protection Bus info motor current x Bus info service data Parameter settings Change-over time via potentiometer x Change-over time via Control Panel fixed basic time 50 ms x Change-over time via PLC program x x x x x x x x fixed basic time 50 ms x x at the motor protecting switch Motor current, trip category x x x optional operating panel Motor current, trip category x x x PLC program Motor current x fixed basic time 50 ms Mounting Mounting on DIN rail x x Mounting on 2 DIN rails x x x x 35 mm DIN rail x 4 Screws M4 x 1 x 2.5 bzw. 2 x 1.5 mm2 max. increased vibration resistance Mounting by screws Connections and conductor cross sections Connecting terminals x x PE tapping directly on DIN rail x x Bus connection via FBP conn. x x x to motor cennecting plug x x x x x x 25 mm2 max. (diameter 11 mm) x Bushing-type transformer Ambient conditions IP20 Degree of protection IP20 IP65 Storage temperature -40...+80°C x x x x x x x x Operating temperature 0...+55°C x x x x x x x x x x x x x x x x Approvals CE, UL, CSA, GL, BV, LRS ATEX partly in preparation x 6/64 1SDC007200C0202 0603_FBP.indd 64 1-12-2006 15:18:40 FBP FieldBusPlug Dimensional drawings Communicative motor starters - compact devices 138 130 120 90 35 52.5 52.5 150 142 120 102 45 35 45 I Dimensions in mm MS 116 I MS 116 0 MSR_Massbild 260 220 125 125 Motor Starter Direct MSD11-FBP 82.5 82.5 MSD_Massbild 260 220 125 125 35 35 0 Motor Starter Reverse MSR22-FBP Communicative motor starters with control functions FBP 20 15 20 11 70 90 62 36 4 6 8 44 PE 5.5 7 9 0 1 2 ERR. INPUT OUTPUT 0 1 2 SUP. 90 MFI21 x10 Addr. x1 120s T1 T2 3 4 I 2 3 L 1 50ms 1s Mfi_Massbild 70 56.5 0 260s 60s 10s 110 103 87.5 MS 325 5 6 7 8 9 UMC22 READY MOT.ON Power 24 DC DI V Out 0 11 12 13 DI 1 14 DI 2 15 DI 3 16 DI 4 17 Motor Starter Fieldbus Interface MFI21-FBP DI 5 18 ca. 40 0 V 10 Relay 5 6 7 8 9 230VAC DO DO DO DO DO 1A C C 0 1 2 Inputs 24V 24VDC 2CDC 342 004 F0006 105 97.5 90 FAULT Power INT. EXT. 45 5 35 – Universal Motor Controller UMC22-FBP 6/65 1SDC007200C0202 0603_FBP.indd 65 1-12-2006 15:18:41 FBP FieldBusPlug Dimensional drawings FieldBusPlugs Dimensions in mm 48.5 17 Earth fault monitor for use with Universal Motor Controller UMC22-FBP 52.5 B 쏗 A ASI-FBP-Plug_Massbild 2CDC 272 044 F0b06 ca. 50 C Type W (A) H (B) D (C) 쏗 CEM11FBP.20 76 31 56 20 CEM11FBP.35 100 31 79 35 CEM11FBP.60 135 38 116 60 Current transformers for use with Universal Motor Controller UMC22-FBP xxx ASD11-FBP, ASP22-FBP, PDP22-FBP, DNP21-FBP, MRP21-FBP 2CDC 342 043 F0006 KORK 4L185 R/4, KORK 4L310 R/4 PDQ22-FBP KORK 5L500 R/4, KORK 5L850 R/4 6/66 1SDC007200C0202 0603_FBP.indd 66 1-12-2006 15:18:42 FBP FieldBusPlug Communicative motor starters - Compact devices Ordering data Motor Starter Direct MSD11-FBP B11_3282 Fuseless motor branch circuit for 1 motor, 1 direction of rotation, IP 20. Motor protection with thermal and electromagnetic tripping. Compact device with fieldbus-independent interface for connection to FBP fieldbus connector. 400 V AC, 12 A max., incl. motor connecting plug and plug for external control voltage (24 V DC). MSD11-FBP Type Motor Starter Direct Setting range ICS kA Order code MSD11-FBP.0.16 MSD11-FBP.0.25 0.1-0.16 A 50 0.16-0.25 A 50 MSD11-FBP.0.4 0.25-0.4 A MSD11-FBP.0.63 0.4-0.63 A MSD11-FBP.1 Price Pack. size Weight p. piece kg 1SAJ 310 000 R0001 1 0.65 1SAJ 310 000 R0002 1 0.65 50 1SAJ 310 000 R0003 1 0.65 50 1SAJ 310 000 R0004 1 0.65 0.63-1.0 A 50 1SAJ 310 000 R0005 1 0.65 MSD11-FBP.1.6 1.0-1.6 A 50 1SAJ 310 000 R0006 1 0.65 MSD11-FBP.2.5 1.6-2.5 A 50 1SAJ 310 000 R0007 1 0.65 MSD11-FBP.4 2.5-4.0 A 50 1SAJ 310 000 R0008 1 0.65 MSD11-FBP.6.3 4.0-6.3 A 50 1SAJ 310 000 R0009 1 0.65 MSD11-FBP.10 6.3-10.0 A 12.5 1SAJ 310 000 R0010 1 0.65 MSD11-FBP.12 10.0-12 A 10 1SAJ 310 000 R0011 1 0.65 Motor Starter Reverse MSR22-FBP MSR22-FBP Type Motor Starter Reverse Setting range ICS kA Order code MSR22-FBP.0.16 0.1-0.16 A 50 MSR22-FBP.0.25 0.16-0.25 A MSR22-FBP.0.4 0.25-0.4 A MSR22-FBP.0.63 MSR22-FBP.1 Price Pack. size Weight p. piece kg 1SAJ 320 000 R0001 1 0.85 50 1SAJ 320 000 R0002 1 0.85 50 1SAJ 320 000 R0003 1 0.85 0.4-0.63 A 50 1SAJ 320 000 R0004 1 0.85 0.63-1.0 A 50 1SAJ 320 000 R0005 1 0.85 MSR22-FBP.1.6 1.0-1.6 A 50 1SAJ 320 000 R0006 1 0.85 MSR22-FBP.2.5 1.6-2.5 A 50 1SAJ 320 000 R0007 1 0.85 MSR22-FBP.4 2.5-4.0 A 50 1SAJ 320 000 R0008 1 0.85 MSR22-FBP.6.3 4.0-6.3 A 50 1SAJ 320 000 R0009 1 0.85 MSR22-FBP.10 6.3-10.0 A 12.5 1SAJ 320 000 R0010 1 0.85 MSR22-FBP.12 10.0-12 A 10 1SAJ 320 000 R0011 1 0.85 FBP Fuseless motor branch circuit for 1 motor, 2 directions of rotation, IP 20. Motor protection with thermal and electromagnetic tripping. Compact device with fieldbus-independent interface for connection to FBP fieldbus connector. 400 V AC, 12 A max., incl. motor connecting plug and plug for external control voltage (24 V DC). Accessories for Motor Starters MSD11-FBP and MSR22-FBP ST022014 Busbar blocks for MSD11-FBP and MSR22-FBP for cross-wiring. Feeder blocks for busbar blocks for MSD11-FBP and MSR22-FBP. Max. current-carrying capacity 63 A, conductor cross section 25/16 mm2 multiple/fine-wire. Type Designation Order code PS1-2-0 Busbar block for 2 devices PS1-3-0 Busbar block for 3 devices PS1-4-0 PS1-5-0 Price Pack. size Weight p. piece kg 1SAM 201 906 R1002 10 0.035 1SAM 201 906 R1003 10 0.056 Busbar block for 4 devices 1SAM 201 906 R1004 10 0.080 Busbar block for 5 devices 1SAM 201 906 R1005 10 0.102 S1-M1 Feeder block, flat design 1SAM 201 907 R1001 10 0.039 S1-M2 Feeder block, high design 1SAM 201 907 R1002 10 0.053 S1-M1 ST020014 ST019014 PS1-x-0 S1-M2 Note: For system accessories and documentation please see end of this chapter. 6/67 1SDC007200C0202 0603_FBP.indd 67 1-12-2006 15:18:50 FBP FieldBusPlug Communicative motor starters with control functions Ordering data Motor starter Fieldbus Interface MFI21-FBP 2CDC 341 081 F0b06 Fieldbus interface, IP20, for coupling to motor protecting switch MS325 1) Integrated motor control functions: Direct starting, reverse starting, star-delta starting. Diagnostic functions, integrated potentiometer. 3 digital inputs, 3 relay outputs, 1 direct-coupled digital input for switch position detection of MS325, fieldbus-independent interface for connection to FBP fieldbus connectors. Type Designation Order code MFI21-FBP.0 Motor starter Fieldbus Interface 1SAJ 410 000 R0100 Price Pack. size Weight p. piece kg 1 0.12 Universal Motor Controller UMC22-FBP Universal motor controller with thermal overload protection 0.24 - 63 A in a single device type. Bushingtype transformer, cable cross section 25 mm2 (max. diameter incl. insulation = 11 mm). Integrated motor control functions: Direct starting, reverse starting, star-delta starting, actuator 2), servo-drive functions. Diagnostic functions: Overload, phase failure, trip categories 5, 10, 20, 30. Integrated storage of parameters and motor data. 6 digital inputs, 1 PTC input, 1 input for external earth fault monitors, 3 relay outputs. Fieldbus-independent interface for connection to FBP fieldbus connectors, interface to operating panel ACS100-PAN. Type Designation Nominal motor current Order code UMC22-FBP.0 Universal MotorController 0.24 - 63 A UMC22-FBP.0 Universal MotorController ATEXVersion 0.24 - 63 A Price Pack. size Weight p. piece kg 1SAJ 510 000 R0400 1 0.36 1SAJ 510 000 R0200 1 0.36 Accessories for Universal Motor Controller UMC22-FBP Control Panel ACS100-PAN Operating, diagnostics and parameter setting panel for Universal Motor Controller UMC22-FBP. Setting of motor and bus parameters. Type Designation Usage with Order code ACS100-PAN Control Panel UMC22-FBP 1SAJ 510 001 R0001 Price Pack. size Weight p. piece kg 1 0.04 Accesories for Control Panel ACS100-PAN Extension cables 0.7 / 3 m and door mounting set IP65 (front side) for ACS100-PAN Control Panel. Type Usage with Order code ACS100-CAB.300 Extension cable 3 m with door mounting set ACS100-PAN ACS100-CAB.070 Extension cable 0.7 m with front mounting set ACS100-PAN Designation Price Pack. size Weight p.piece kg 1SAJ 510 002 R0001 1 0.40 1SAJ 510 003 R0001 1 0.40 1) For motor protecting switch MS325 and accessories for MS325 please refer to chapter Motor Protecting Switches 6/68 1SDC007200C0202 0603_FBP.indd 68 1-12-2006 15:18:51 FBP FieldBusPlug Communicative motor starters with control functions Ordering data 2CDC 345 094 F0b06 Earth fault monitor CEM11-FBP for Universal Motor Controller UMC22-FBP Type Earth fault currents [mA] Through hole diameter Order code CEM11-FBP.20 80 1), 300, 550, 750, 1000, 1200, 1500, 1700 20 mm CEM11-FBP.35 100 1), 500, 1000, 1400, 2000, 2400, 3000, 3400 CEM11-FBP.60 120 1), 1000, 2000, 2800, 4000, 4800, 6000, 6800 Price Pack. size Weight p. piece kg 1SAJ 929 200 R0020 1 0.130 35 mm 1SAJ 929 200 R0035 1 0.200 60 mm 1SAJ 929 200 R0060 1 0.330 Current transformers for use with the Universal Controller UMC22-FBP Type Current range recommanded Order code KORC 4L 185 R/4 60 ... 185 A KORC 4L 310 R/4 Price Pack. size Weight p. piece kg 1SCA 022 193 R7830 1 1.550 180 ... 310 A 1SCA 022 181 R0760 1 1.442 KORC 5L 500 R/4 300 ... 500 A 1SCA 022 208 R1010 1 1.700 KORC 5L 850 R/4 500 ... 850 A 1SCA 022 208 R1440 1 1.900 S01261A KORC 4L... FBP S01260A Secundary-linear transformer, 3-phase with terminal block, intended for conductors Cu 2.5 mm2 KORC 5L... Connection kit for use with the KORC-current-transformers Connection kit for applications with KORC-current-transformers with A-series-contactors 1) Type Designation Appropriate for contactor type DT 450 / A185 Connection kit DT 450 / A300 DT 500 / AF460L Order code Price Pack. size Weight p. piece kg AF145 - AF185 1SAZ 501 901 R1001 1 0.500 Connection kit AF260 - AF300 1SAZ 501 902 R1001 1 0.750 Connection kit 2) AF400 - AF460 1SAX 701 902 R1001 1 0.500 Lowest values have higher inaccuracy 6/69 1SDC007200C0202 0603_FBP.indd 69 1-12-2006 15:18:53 FBP FieldBusPlug Further FBP terminal devices Overview Communicative Power Circuit Breakers Tmax T4 / T5 / T6 and Emax 1SDC 200 305 F0001 FBP interface module EP010 for connection to the FieldBusPlug. 1SDC210306F0004 1SDC210305F0004 EP010 Tmax T4/T5 Communicative Soft Starter PST 1SFC132013F0201 Compact device with fieldbus-neutral interface for connection to the FieldBusPlug. Soft Starter PST Position sensors inductive and capacitive SST05597 SST05497 PNP-NO with M12 connection, operating at all FieldBusPlugs. Position Sensors Input module for Wireless Proximity Switches 2CDC35001F0003 Input module with fieldbus-neutral interface for connection up to 120 wireless position sensors. Input module WDI 6/70 1SDC007200C0202 0603_FBP.indd 70 1-12-2006 15:18:54 FBP FieldBusPlug AS-Interface - FieldBusPlugs Ordering data AS-Interface FieldBusPlug Direct Ready-made AS-Interface slave fieldbus interface with various cable lengths. Applicable with MSD11-FBP and terminal devices with max. 2 input and 1 output signals. Degree of protection IP65, diagnostic LED. Type Designation Cable length ASD11-FBP.025 AS-Interface FBP Direct 0.25 m ASD11-FBP.050 AS-Interface FBP Direct 0.50 m ASD11-FBP.100 ASD11-FBP.500 Order code Price Pack. size Weight p.piece kg 1SAJ 210 000 R0003 1 0.09 1SAJ 210 000 R0005 1 0.10 AS-Interface FBP Direct 1.00 m 1SAJ 210 000 R0010 1 0.13 AS-Interface FBP Direct 5.00 m 1SAJ 210 000 R0050 1 0.33 ASD11-FBP AS-Interface FieldBusPlug Performance Ready-made AS-i slave fieldbus interface with various cable lengths. Applicable with all FBP motor starters and terminal devices with max. 4 input and 3 output signals. Degree of protection IP65, diagnostic LED. Designation Cable length Order code ASP22-FBP.025 AS-Interface FBP Performance 0.25 m ASP22-FBP.050 AS-Interface FBP Performance ASP22-FBP.100 ASP22-FBP.500 Price Pack. size Weight p.piece kg 1SAJ 220 000 R0003 1 0.09 0.50 m 1SAJ 220 000 R0005 1 0.10 AS-Interface FBP Performance 1.00 m 1SAJ 220 000 R0010 1 0.13 AS-Interface FBP Performance 5.00 m 1SAJ 220 000 R0050 1 0.33 FBP Type ASP22-FBP Note: For system accessories and documentation see end of this chapter. 6/71 1SDC007200C0202 0603_FBP.indd 71 1-12-2006 15:18:56 FBP FieldBusPlug AS-Interface - Accessories Ordering data Accessories for the AS-Interface bus connection AS-Interface round cables for bus junctions ST04901 Ready-made bus cable with M12 connector and open cable end. Applicable for bus junctions such as e.g. AS-Interface couplers or devices with integrated AS-Interface communication. Type AS-Interface round cable for bus junctions Cable length Order code ASF11-FBP.030 Round cable with female connector 0.30 m ASM11-FBP.030 Round cable with male connector 0.30 m Pack. size Weight p. piece kg 1SAJ 922 002 R0003 1 0.03 1SAJ 922 003 R0003 1 0.03 Pack. size Weight p. piece kg 1 0.08 ST05901 ASF11-FBP.030 Price ASM11-FBP.030 AS-Interface round cables for bus extensions ST05101 Ready-made AS-Interface bus cable, round cable with M12 female and male connectors (ASX11-FBP.xxx), AS-Interface bus cable, round cable on coil (ASC11-FBP.999). ASX11-FBP Type AS-Interface extension cables Cable length Order code ASX11-FBP.100 Ready-made 1.00 m 1SAJ 922 001 R0010 Price ASX11-FBP.300 Ready-made 3.00 m 1SAJ 922 001 R0030 1 0.18 ASX11-FBP.500 Ready-made 5.00 m 1SAJ 922 001 R0050 1 0.28 ASC11-FBP.999 Coil 100 m 1SAJ 922 004 R1000 1 5.20 Pack. size Weight p. unit kg ASF11-FBP.0 Type AS-Interface cable connectors Order code Price ASM11-FBP.0 Male AS-Interface round c. conn. 1SAJ 922 005 R0001 5 0.15 ASF11-FBP.0 Female AS-Interf. round c. conn. 1SAJ 922 006 R0001 5 0.15 AST11-FBP.0 Flat cable branch circuit with M12 socket (junction to round cable) 1SAJ 922 007 R0001 1 0.11 Pack. size Weight p. unit kg 1 0.56 ST05601 ASM11-FBP.0 ST05701 ST05501 AS-Interface accessories for the bus extension AST11-FBP.0 AS-Interface addressing unit, miscellaneous accessories Type Designation Order code ASA21-FBP.0 Adressing unit incl. plug-in power supply unit 1SAJ 922 010 R0001 Price Note: For system accessories and documentation see end of this chapter. 6/72 1SDC007200C0202 0603_FBP.indd 72 1-12-2006 15:18:56 FBP FieldBusPlug PROFIBUS DP-V0 and DP-V1 - FieldBusPlugs Ordering data PROFIBUS DP-V0 and DP-V1 FieldBusPlug Ready-made PROFIBUS DP-V0 and DP-V1 fieldbus interface with various cable lengths. Basis functions with DP-V0. Basis functions plus additional functions with DP-V1. Applicable with all FBP motor starters and other terminal devices. Degree of protection IP65, diagnostic LED. 2CDC 341 048 F0b06 PDP22-FBP Type Cable length Order code PDP22-FBP.025 0.25 m PDP22-FBP.050 Price Pack. size Weight p. piece kg 1SAJ 240 100 R1003 1 0.09 0.50 m 1SAJ 240 100 R1005 1 0.10 PDP22-FBP.100 1.00 m 1SAJ 240 100 R1010 1 0.13 PDP22-FBP.200 2.00 m 1SAJ 240 100 R1020 1 0.20 4 x PROFIBUS DP-V0 and DP-V1 FieldBusPlug PDQ22 is a member of the ABB FieldBusPlug family of bus connectors. It allows the connection of up to four devices to PROFIBUS DP by just using one PROFIBUS node address. This allows a cost efficient device integration for devices that are located physically nearby. PDQ22 supports DP-V0 and DP-V1. The degree of protection is IP65. There are separate diagnosis LEDs for bus and device status. Order code Price Pack. size Weight p. piece kg FBP Type PDQ22-FBP DIN rail adapter for PROFIBUS FieldBusPlug PDQ22-FBP Type Designation Order code Price Pack. size Weight p. piece kg Type Designation Order code Price Pack. size Weight p. piece kg CDP15-FBP.150 Extension cable (female/male), shielded, 1.5 m 1SAJ 929 140 R0015 1 0.20 Extension cable Note: For system accessories and documentation see end of this chapter. 6/73 1SDC007200C0202 0603_FBP.indd 73 1-12-2006 15:18:57 FBP FieldBusPlug PROFIBUS DP-V0 and DP-V1 - Accessories Ordering data PROFIBUS DP-V0, DP-V1 round cables for bus junctions Ready-made bus cable with M12 connector and open cable end. Applicable for bus junctions such as e.g. PROFIBUS DP-V0, DP-V1 couplers or devices with integrated PROFIBUS DP-V0, DP-V1 communication. Type Designation Cable length Order code PDF11-FBP.050 with female connector 0.50 m 1SAJ 924 002 R0005 Price Pack. size Weight p. piece kg 1 0.04 PROFIBUS DP-V0, DP-V1 round cables for the bus extension Ready-made PROFIBUS DP-V0 and DP-V1 bus cable, round cable with M12 female and male connectors (PDX11-FBP.xxx). PROFIBUS DP-V0 and DP-V1 bus cable, round cable on coil (PDC11-FBP.999). Type Designation Cable length Order code PDX11-FBP.100 Ready-made 1.00 m 1SAJ 924 001 R0010 Price Pack. size Weight p. piece kg 1 0.08 PDX11-FBP.300 Ready-made 3.00 m 1SAJ 924 001 R0030 1 0.20 PDX11-FBP.500 Ready-made 5.00 m 1SAJ 924 001 R0050 1 0.31 Pack. size Weight p. piece kg 1 0.03 PROFIBUS DP-V0 and DP-V1 accessories for the bus extension Type Designation Order code PDM11-FBP.0 Male round cable connector 1SAJ 924 005 R0001 Price PROFIBUS DP-V0 and DP-V1 line termination, feeding connector, adaptor Type Designation Order code PDR11-FBP.150 Line termination 150 Ohm PDV11-FBP.0 Price Pack. size Weight p. piece kg 1SAJ 924 007 R0001 1 0.03 Feeding connector 24 V DC Code B-A 1SAJ 924 008 R0001 1 0.04 PDV12-FBP.0 Feeding connector 24 V DC Code A-A 1SAJ 924 011 R0001 1 0.04 PDA11-FBP.050 Adaptor M12-Dsub9-M12 cable length 0.50 m 1SAJ 924 009 R0005 1 0.04 6/74 1SDC007200C0202 0603_FBP.indd 74 1-12-2006 15:18:58 FBP FieldBusPlug DeviceNet, MODBUS-RTU - FieldBusPlugs Ordering data DeviceNet FieldBusPlug Ready-made DeviceNet fieldbus interface with various cable lengths. Applicable with all FBP motor starters and other terminal devices. Degree of protection IP65, diagnostic LED. B10_3282_RET Type DNP21-FBP MRP21-FBP Cable length Order code Price Pack. size Weight p. piece kg DNP21-FBP.025 0.25 m 1SAJ 230 000 R0003 1 0.09 DNP21-FBP.050 0.50 m 1SAJ 230 000 R0005 1 0.10 DNP21-FBP.100 1.00 m 1SAJ 230 000 R0010 1 0.13 MODBUS-RTU FieldBusPlug Ready-made MODBUS-RTU fieldbus interface with various cable lengths. Applicable with all FBP motor starters and other terminal devices. Degree of protection IP65, diagnostic LED. Type Cable length Order code MRP21-FBP.025 0.25 m 1SAJ 250 000 R0003 Price Pack. size Weight p. piece kg 1 0.09 0.50 m 1SAJ 250 000 R0005 1 0.10 1.00 m 1SAJ 250 000 R0010 1 0.13 FBP MRP21-FBP.050 MRP21-FBP.100 6/75 1SDC007200C0202 0603_FBP.indd 75 1-12-2006 15:19:00 FBP FieldBusPlug DeviceNet, MODBUS-RTU - Accessories Ordering data Accessories for the DeviceNet, MODBUS-RTU, bus connection DeviceNet, MODBUS-RTU round cables for bus junctions ST05301 Ready-made bus cable with an M12 plug and an open cable end. Applicable with bus junctions such as DeviceNet, MODBUS-RTU couplers or devices with an integrated DeviceNet, MODBUS-RTU communication. Type DeviceNet, Cable MODBUS-RTU round length cables for bus junctions Order code DNF11-FBP.050 Round cable with male plug 0.50 m 0.50 m ST05201 DNM11-FBP.050 Round cable Price Pack. size Weight p. piece kg 1SAJ 923 002 R0005 1 0.04 1SAJ 923 003 R0005 1 0.04 DeviceNet, MODBUS-RTU round cables for the bus extension ST04801 Ready-made DeviceNet, MODBUS-RTU bus cable, round cable with M12 male and female plugs (DNX11-FBP.xxx). DeviceNet, MODBUS-RTU bus cable, round cable as a coil (MRC11-FBP.999). Type DeviceNet, MODBUS-RTU extension cables DNX11-FBP.100 Ready-made DNX11-FBP.300 DNX11-FBP.500 Pack. size Weight p. piece kg 1.00 m 1SAJ 923 001 R0010 1 0.08 Ready-made 3.00 m 1SAJ 923 001 R0030 1 0.20 Ready-made 5.00 m 1SAJ 923 001 R0050 1 0.31 100.00 m 1SAJ 923 004 R1000 1 5.60 Pack. size Weight p. piece kg DNC11-FBP.999 Coil (Drop cable) Cable length Order code Price DeviceNet, MODBUS-RTU accessories for the bus extension ST05401 ST05701 Type DeviceNet, Order code MODBUS-RTU cable connectors Price DNM11-FBP.0 Round cable male plug 1SAJ 923 005 R0001 5 0.15 DNF11-FBP.0 Rund cable female plug 1SAJ 923 006 R0001 5 0.15 Pack. size Weight p. piece kg 1 0.02 DeviceNet, MODBUS-RTU termination resistor and other accessories ST05501 Type DeviceNet, MODBUS-RTU bus accessories DNR11-FBP.120 Terminating resistor 120 Ohm Order code 1SAJ 923 007 R0001 Price Note: For system accessories and documentation see end of this chapter. 6/76 1SDC007200C0202 0603_FBP.indd 76 1-12-2006 15:19:01 FBP FieldBusPlug System accessories and documentation Ordering data FieldBusPlug addressing labels For addressing the FieldBusPlug connectors. Type Designation Order code CAL11-FBP.0 400 Adressing labels for FBPs 1SAJ 929 005 R0001 Price Pack. size Weight p. unit kg 1 0.15 Pack. size Weight p. unit kg FieldBusPlug power supply unit Supply voltage 90...260 V AC, 47...63 Hz. Adjustable output voltage 23...28 V DC, 5 A. Type Order code Designation Price FBP Addressing-Set for PROFIBUS DP-V0, DP-V1, DeviceNet, MODBUS-RTU For setting the FieldBusPlug connector address (PROFIBUS DP and DeviceNet). Consisting of software package for notebook, level converter incl. battery and cable to notebook. Order code Designation Price Pack. size Weight p. unit kg FBP Type FieldBusPlug accessories for installation inside control cabinet drawer systems Fixing bracket for passive plug for installation of FBP terminal devices in drawer systems. FBP passive cable for installation of FBP terminal devices in drawer systems. Type Designation CDP11-FBP.0 Passive plug fixing bracket for drawer systems CDP12-FBP.100 Passive cable for drawer systems (outside) Length 1.00 m Order code Price Pack. size Weight p. piece kg 1SAJ 929 100 R0001 50 0.50 1SAJ 929 120 R0001 1 0.20 Pack. size Weight p. piece kg FieldBusPlug system documentation Complete system documentation for planning and project planning. Technical data, software, examples, FAQs. Type Language Order code Price 6/77 1SDC007200C0202 0603_FBP.indd 77 1-12-2006 15:19:02