CAKA - FRS
Transkript
CAKA - FRS
YETKÝLÝ SERVÝSLER Ankara Fabrika Aðaç Ýþleri Yapý Koop. 21. Cad. 596. Sok. No: 10 Ostim / ANKARA Tel : +90 312 395 55 05 Fax: +90 312 395 02 75 E-mail: info@frsgaz.com.tr Ankara Sevin Ýþhaný No: 7/53 Rüzgarlý Ulus / ANKARA Tel : +90 312 324 00 29 Fax: +90 312 324 00 79 Ýstanbul Kayýþdaðý Yolu Caddesi No: 76/4 Ýçerenköy-Ataþehir / ÝSTANBUL Tel : +90 212 575 88 15 Fax: +90 212 575 88 25 577 09 65 Ýstanbul Emniyet Evleri Mahallesi Oðuzhan Sokak No: 5/A 4 Levent / ÝSTANBUL Tel : +90 212 279 89 25 Fax: +90 212 281 45 93 Ýzmir 1201. Sokak No: 13 B Blok Z 20 Yeniþehir / ÝZMÝR Tel : +90 457 05 30 Fax: +90 457 05 60 CAKA-XL SERÝSÝ SERIES Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator CAKA-XL series are pilot operating with axial flow regulators designed for a long life and high performance. Built in shut-off valve protects the system from very high and very low pressures. CAKA-XL series of regulators are designed to be used in industrial and construction systems, industrial stations, city district and city gate stations. CAKA-XL serisi regülatörler, endüstriyel ve inþaat sistemleri, endüstriyel istasyonlar, gaz reglaj istasyonlarý, ýsýtma sistemleri ve brülör gibi alanlarda kullanýlmasý için dizayn edilmiþtir. These regulators are suitable for filtered and non-corrosive gasses. Bu regülatörler filtre edilmiþ ve korozif olmayan gazlar için uygundur. XL 25 XL 40 XL 50 XL 80 Our products have been largely appreciated worldwide for their safety,reliability, versatility and long life high performance. Aksiyal akýþlý regülatörler, dünya üzerindeki kullanýcýlar tarafýndan çok yönlülüðü, güvenilirliði ve aðýr þartlar için geliþtirilmiþ uzun ömürlü regülatörler olarak bilinirler. Uzun Ömür Kolay Bakým Yüksek Hassasiyet Geniþ Uygulama Aralýðý Kompakt Dizayn Modüler Dizayn Düþük Ses Seviyesi Patlamasý Ýmkansýz Diyafram A105 Çelikten Ýþlenmiþ Gövde CONFIGURATIONS BASIC FEATURES Sahip olduðu shut-off valf tesisatýnýzý yüksek ve düþük çýkýþ basýnçlarýna karþý korur. GÖRÜNÜÞLER TEMEL ÖZELLÝKLER CAKA-XL serisi regülatörler; endüstriyel ve inþaat sistemleri, endüstriyel istasyonlar, þehir bölge ve þehir besleme istasyonlarý gibi alanlarda kullanýlmalarý için dizayn edilmiþlerdir. Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator Long Life Easy Maintance High Accuracy Wide Application Compact Design Modularity Design Low Noise Level Full Strength Diaphragm Body A105 Made BXL 25 BXL 40 BXL 50 BXL 80 MXL 25 MXL 40 MXL 50 MXL 80 CAKA CAKA S E R Ý S Ý S E R Ý S Ý 1 frsgaz.com.tr frsgaz.com.tr 2 Technical Features Basýnç Sýnýfý PN 16/25 - ANSI 300-600 Pressure Class PN 16/25 - ANSI 300/600 MaksimumGiriþ Basýncý (P ) :100 bar a kadar Allowable Pressure (P ) : up to 100 bar Giriþ Basýncý Aralýðý (bpe) : 0,2 -100 bar Inlet Pressure (bpe) : 0,2 to 100 bar Çýkýþ Basýncý Aralýðý (Wh) : 0,01 - 48 bar Outlet Pressure Range (Wh) : 0,01 to 48 bar zul zul Basýnç Sýnýfý PN 16/25 - ANSI 150 Pressure Class PN 16/25 - ANSI 150 Maksimum Giriþ Basýncý (P ) : 25 bar a kadar Maximum Inlet Pressure (P ) : up to 25 bar Giriþ Basýncý Aralýðý (bpe) : 0,2 - 25 bar Inlet Pressure Range (bpe) : 0,2 to 25 bar Çýkýþ Basýncý Aralýðý (Wh) : 0,01 - 8 bar Outlet Pressure Range (Wh) : 0,01 to 8 bar zul zul Fonksiyonel Özellikler REGÜLATÖR SEÇÝMÝ SELECTION OF REGULATOR a) Regülatör seçiminde iþletmedeki max kapasite dikkate alýnmalýdýr. Bu seçimde özellikle tek kademeli çalýþan sistemler için kapasitede % 10 emniyet payý alýnmasýnde fayda vardýr. b)Regülatör öncesindeki ve sonrasýndaki boru çaplarý regülatör kapasitesini etkiler. Regülatör çýkýþ borusunda gaz hýzý 160 m/s yi geçmemelidir. Geçmesi durumunda oluþan türbülans nedeniyle regülatör salýným yapmaya baþlar ve istenilen kapasiteye ulaþamaz. c) Caka serisi regülatörlerden en iyi performansý almak için çýkýþlarýnda slam-shut ve regülator impuls baðlantýlarý flaþtan itibaren 5XDN uzaklýktaki olmalýdýr. d) Regülatör seçimi aþaðýdaki tablodan veya Cg deðerlerinden giderek yapýlabilir. a) When coosing a regulator one should pay attention to the maximum capacity in the establishment. In this selection especially when concerning single graded working systems it is beter to have % 10 margin of safety. b) Diameters of the pipes before and after the regulator affects the regulator capacity gas flow speed shall not pass 160 m/s in the outlet pipe of the regulator. If it does because of the emerging turbulance the regulator starts swaying and therefore cannot reach the optimum capacity. c) To maintain optimum performance from the CAKA series of regulators, there should be 5D distance between slam-shut and regulator impuls connections. d) Selection of the regulator can be made from the chart below or by considering Cg values. Q : Debi / Flow (m3/h) Pi : Giriþ Basýncý / Inlet Pressure (bar) Po : Çýkýþ Basýncý / Outlet Pressure (bar) Cg : Akýþ Katsayýsý/Flow Coefficient. Akýþ aþaðýdaki denklemler kullanýlarak hesaplanýr. Functional Features Hassasiyet Sýnýfý (AC) : % 1e kadar Accuracy Class (AC) : up to = 1% Kapatma Basýncý Sýnýfý (SG) : % 5e kadar Lock-up Pressure class (SG) : up to + 5% Flow is calculated with using the following equations. Eðer/If (Pi -P0 ) < 0,5 P i Q = Cg P0 ( Pi - P0 ) Eðer/If (Pi -P0 ) > 0,5 Pi Q = 0,5 Cg Pi Tablo / Chart - 1: Akýþ Katsayýsý / Flow Coefficients Emniyet Kapama Cihazý Shut-Off Device Hassasiyet Sýnýfý (AG): 1 % e kadar Accuracy Class (AG): up to = 1 % Tepki Süresi (ta) Response Time (ta) : _ 1s : _ 1s Flanþlý Baðlantýlar Flanged Connections Giriþ ve Çýkýþ: DN 25/40/50/80 Same Inlet and Outlet: DN 25/40/50/80 DN XL MXL BXL 25 Cg 525 450 500 40 Cg 1350 1150 1100 50 Cg 2200 1950 1900 80 Cg 5100 4600 4000 Farklý yoðunluklardaki diðer gazlar için yukarýdaki formulle hesaplanan akýþ oraný aþaðýdaki düzeltme faktörü ile çarpýlmalýdýr. Sýcaklýk Temperature Çalýþma : -20 o C - +60 o C Working : -20 o C - +60 o C Malzemeler Materials Flanþlar ve Kapaklar : ASTM A105 Flangers and covers : ASTM 105 Diyafram : Fabric NBR + PVC / Diaphrangms : Fabric NBR + PVC / Nitrile Rubber Nitrile Rubber Ped : NBR Nitrile Rubber Pads : NBR Nitrile Rubber CAKA For other gases with different densities, the flow rate calculated with the above formulas must be multiplied by the correction factor. 175,8 S (273,16+T) F= Tablo / Chart - 2: Göreceli Yoðunluk ve Düzeltme Katsayýsý / Relative Density and Correction Factor GAZ TÝPÝ / TYPE OF GAS GÖRECELÝ YOÐUNLUK / RELATIVE DENSITY (d) FAKTÖR / FACTOR ( Fc ) Hava / Air 1,0 0,78 Propan / Propane 1,53 0,63 Bütan / Butane 2,0 0,55 Azot / Nitrogen 0,97 0,79 Oksijen / Oxygen 1,14 0,73 Karbondioksit / Carbondioxide 1,52 10,63 CAKA S E R Ý S Ý S E R Ý S Ý 3 frsgaz.com.tr frsgaz.com.tr 4 CALCULATION PROCEDURES AND SELECTÝON OF REGULATOR Teknik Özellikler Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator HESAPLAMA PROSEDÜRLERÝ VE REGÜLATÖR SEÇÝMÝ TECHNICAL AND FUNCTIONAL SPECIFICATIONS TEKNÝK VE FONKSÝYONEL ÖZELLÝKLER Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator OPERATION OPERATION ÝÞLEYÝÞ Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator ÝÞLEYÝÞ Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator AKSÝYAL AKIÞLI REGÜLATÖR NASIL ÇALIÞIR HOW DOES THE AXIAL FLOW REGULATOR WORK Regülatör iki odacýktan oluþmaktadýr. Bu odalardan bir tanesi The Diaphragm Unit (permanently connected to the shutter) divides the regulator control head into two chambers. One of the chambers is connected to regulated pressure and the other to moving pessure produced by the pilot according to pressre downstream. Due to lack of pressure, the regulator spring scts on th diaphragm unit and closes the shutter.The actuator that is shaped as a piped shut of the gas without changing its direction. çýkýþ basýncýna ve diðer odacýk ise giriþ ve çýkýþ basýncýndan sens alan pilot tarafýndan yaratýlmýþ basýnca baðlýdýr. Boru þeklindeki aktüatör ise gazýn yönünü deðiþtirmeden kapama yapmasýný saðlar. Aktüatör diyaframdaki hareket eden basýnçtan doðan güçle açýk pozisyona gelir ve böylece çýkýþ basýncýndan daha yüksek bir güç regülatör yayýna yüklenmiþ olur. Bu þartlar altýnda eðer iki güç birbirine eþit ise kapatýcý atýl durumda kalýr ki bu durumda çýkýþ basýncý ile sistemin sabit deðeri eþittir. Ýstenilen basýnç oranýndaki herhangi bir deðiþiklik regülatör çýkýþ basýncýnda deðiþikliðe yol açar ve pilot tarafýndan kontrol edilen regülatör gerekli akýþ oranýný saðlamak için açýlýr veya kapanýr ve bu sayede çýkýþ basýncýný uygun seviyede tutar. The Shutter moves to ist open position when the force produced by moving pressure acting on the diaphragm unit becomes greater than the force produced by downstream regulated pressure (Pa) added to the load of the regulator spring. The shutter stays idle when the two forces are equal under these conditions, downstream pressure is equal to the systems set value. Any change in requasted flow-rate produces avariation in downstream regulated pressure and the regulator controlled by the pilot opens or closes to deliver the requested flow-rate while keeping downstreampressure uniform. MONÝTÖR REGÜLATÖR SÝSTEMÝ HOW DOES THE MONITOR WORK Monitör regülatör aslýnda bir emniyet sistemidir. Çýkýþ basýncýnda yükselme olduðunda sistemin devre dýþý kalmadan devamýný saðlar. Çýkýþ basýncýnýn yükselmesi aktif regülatörün arýzalanmasýndan kaynaklanýr. Aktif Regülatör ise arýzalandýðýnda komple açýlýr ve boru halinde gelir.Monitör regülatör devreye girerek basýncý sabit tutar. The monitor regulator is in fact a safety system. If there has to be an increase on the outlet pressure it provides the system to keep working without been out of circuit. A breakdown in the active regulator causes outlet pressure to increase. If there shall be a breakdown in the active regulator its opened up completely and turn into a pipe. In such a case monitor regulator stabilizes the pressure. CAKA CAKA S E R Ý S Ý S E R Ý S Ý 5 frsgaz.com.tr frsgaz.com.tr 6 Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator BXL OPERATION ÝÞLEYÝÞ ÞEMATÝK SCHEMATIC Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator AKSÝYAL AKIÞLI KAPATMA CÝHAZI NASIL ÇALIÞIR HOW DOES THE AXIAL FLOW SHUT-OFF DEVICE WORK Emniyet kapatma cihazýnýn bir kapatýcýsý ve kendisine ait seat The shut-off device has a shutter and its own seat and is provided bulunur ve aygýt regülatör/monitörden baðýmsýz olarak with functions independent of the regulator/monitor. çalýþabilmektedir. Actuator pilot series B-LP and B-HP are designed to operate on either B-LP ve B-HP aktüatör pilot serilerinin her ikisi ya maksimum maximum or minimum pressure. ya da minimum seviyede çalýþmak üzere dizayn edilmiþlerdir. When the systems downstream pressure is at normal operating Sistem çýkýþ basýncý normal çalýþma seviyesindeyken aktüatör value, the actuator-pilot remains set and prevents the shut-off reset shaft pilot kurulu durur ve shut-off u açýk tutarak shut-off reset milinin from tuming by keeping the shut-off open. dönmesini engeller. When downstream pressure values beyond its set limits, the Çýkýþ basýncý limitlerinin ötesi bir deðerdeyken aktüatör pilot actuator pilot releases the reset shaft and the shutter is closed by the reset milini serbest býrakýr ve kapatýcý yayýn itme kuvveti ile kapanýr. thrust of the spring. Emniyet kapatma sadece manuel olarak kurulabilir. Bunun için shut-off mili saat yönünün tersine çevrilmelidir. The shutter can be opened by hand only, by rotating the shut-off reset shaft anti-clockwise. CAKA CAKA S E R Ý S Ý S E R Ý S Ý 7 frsgaz.com.tr frsgaz.com.tr 8 Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator MXL BOYUTLAR OVERAL DIMENSIONS ÞEMATÝK SCHEMATIC Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator DIMENSIONS DN DIMENSIONS PN 16 - ANSI 150 A B XL MXL BXL 25 40 50 184 222 254 360 424 510 355 410 485 285 306 335 199 206 213 80 298 564 560 40 245 DN ANSI 300 - ANSI 600 A B XL MXL BXL 25 40 50 210 251 286 385 450 535 390 445 515 225 365 287 199 206 213 80 337 600 600 400 245 CAKA CAKA S E R Ý S Ý S E R Ý S Ý 9 frsgaz.com.tr frsgaz.com.tr 10 / Inlet Valve 2. Filtre / Filter 3. Manometre / Manometer 4. Regülatör / Regulator 5. Pilot / Pilot Parça No: 6. Regülatör Ýmpuls Hattý / Regulator Impulse Line 1 2 5 3 4 7. Manometre / Manometer 8. Relief Valf / Relief Valve 9. Boþaltma Vanasý / Drain 10.Çýkýþ Vanasý / Outlet Valve 6 7 8 9 ÝSTASYON KURULUMU ÖNCESÝ DÝKKAT EDÝLMESÝ GEREKEN HUSUSLAR * Regülatör dýþ ortamdan korunan bir bölgede montaj edilmelidir. * Cihaz havanýn dýþ etkilerine karþý korunmalýdýr. * Regülatörün kurulacaðý yerin sistem gereksinimlerine uygun olup olmadýðýndan emin olunmalýdýr. KURULUM 1. Montajý yapýlmýþ regülatör üzerindeki gaz akýþ yönünün doðru olup olmadýðý kontrol edilmelidir. 2. Regülatörün sürekli ve stabil olarak çalýþabilmesi için regülatörün öncesine filtre konulmalýdýr. 3. Regülatörün giriþinde ve çýkýþýnda hat kesme vanasý ve manometre bulunmasý, devreye alma ve bakým gibi durumlarda gereklidir. 4. Hattýn gazýný tahliye edebilmesi için drain veya vent vanalarý konulmalarý tavsiye edilir. 5. Regülatör ok yönüne göre ve Þekil-1 de gösterildiði gibi monte edilmelidir. 6. Regülatörden sonra kullanýlacak relief vana herhangi bir þekilde artan çýkýþ basýncýndan dolayý sistemin zarar görmesini engeller. 7.Regülatör ve slam-shut sens hatlarý regülatörden 5D minimum uzaklýkta ve borunun yan veya üstünden olmalýdýr. 8.Regülatör sonrasý gaz hýzlarý 50 m/s geçemeyecek þekle boru çapý hesaplanmalýdýr. 9. Regülatörün hemen sonrasýnda brülör gibi yakma ekipmanlarý var ise en az 6D boru hattý býrakýlmasý tavsiye edilir. CAKA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 10 PRE-INSTALLATION CAUTIONS OF THE STATIONS *Install the regulator in a sheltered area. *Make sure to protect it from weather hazards. REGÜLATÖR KURULUM PARÇA ADI Gövde Gövde Üst Flanþý O-ring Teflon Ara Parça M12 Saplama Çýkýþ Flanþý Alt Flanþ Çýkýþ Flanþý Polyamid Yataklama Orta Mil Orta Mil 2 Kare Conta Kare Conta Flanþý Üst Kare Conta Flanþý Alt Yay Giriþ Flanþý Üst Flanþ Flanþ Kapaklarý Flanþ Kapak Pulu Kare Conta Kapak Pim Kurma Mili Kurma Mili Yataðý INSTALLATION OF THE REGULATOR a. Regülatörü dýþ ortamdan korunan bir bölgede montaj edin. Cihazý havanýn etkilerine karþý koruyunuz. b. Regülatörün kurulacaðý yerin sistem gereksinimlerine uygun olup olmadýðýndan emin olunmalýdýr. a. Install the regulator in a sheltered area and make sure to protect it from weather hazards. b. Make sure to have all system requirements provided in the installation c. area of the regulator. c. Montajý yapýlmýþ regülatör üzerindeki gaz akýþ yönünün doðru olup olmadýðýný kontrol edin. After the installation of the regulator, check and make sure that gas flows in the direction indicated by the arrow. *Make sure to have all system requirements provided in the installation are a of the regulator. INSTALLATION 1.After the installation of the regulator, check and make sure that gas flows in the direction indicated by the arrow. 2.The filter should be placed in front of the regulator to provide the regulator 1 work continiously and stable. 3.A manometer and a valve is needed for commissioning process and maintanence on the inlet and oulet pipes of the regulator. 4.Its recommended to have a drain or vent valve in order to drain the gas in the pipes when necessary. 5.The regulator must be assembled in direction of the arrow and as shown on Figure-1. 6.Assembling a relief valve on the outlet pipe protects the regulator from high pressure that might ocur by any reason. 7.The regulator and slam-shut sense lines must be at least 5D away from the regulator and they should be placed either the side or the top of the pipe. 8.Speed of the gas flow after the regulator should be calculated as maximum 50 m/s. 9.If there are equipments such as a burner right after the regulator, its recommended for them to be placed at least 6D away from the pipeline. BASINÇ AYARLAMA SETTING THE REGULATOR PRESSURE a. Regülatör devreye alma prosedüründeki gibi kurulur. b. Çýkýþ basýncý pilot üzerindeki yay ayar vidasý sýkýlarak istenilen büyüklüðe getirilir. 2 a. Regulator is set as instructed in the commissioning procedure. b. Outlet pressure is set to adequate pressure by screwing the adjustment spring on the pilot. c. Ýstenilen basýnç saðlandýktan sonra yay kapaðý takýlýr ve çýkýþ vanasý kapalýyken köpükle gaz kaçýrýp kaçýrmadýðý kontrol edilir. c. After the adequate pressure has been provided, assemble the spring cap and check if there shall be any leaks by applying soapy water with a sponge. d. Çýkýþ basýncýnýn, çýkýþ vanasý kapalýyken artmadýðý kontrol edilmelidir. Slam-shut yüksek basýnç ve düþük basýnç nedeni ile atýyordur. SSV üzerindeki 1 numara ile gösterilen yay saat yönünde, 2 numara ile gösterilen pirinç vida ise gevþetilerek istenilen deðere düþürülür. d. Check if the outlet pressure increases or not when the outlet valve is turned off. Slam-shut shuts it self of because of very high or low pressure. In such a case; The spring (1) shown on Figure 1 on the SSV should be turned clock-wise and the brass seal (2) should be loosened till the optimum value is established. CAKA S E R Ý S Ý S E R Ý S Ý 11 frsgaz.com.tr frsgaz.com.tr 12 ASSEM BLY, INSTALLATION AND COMMISSIONING 1. Giriþ Vanasý Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator MONTAJ, KURULUM VE DEVREYE ALMA INSTALLATION OF STATION ÝSTASYON KURULUMU Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator COMMISSIONING a. Regülatör giriþ tarafýndaki vana açýlýr. Regülatörün slamshut mekanizmasý kapalý olduðundan gaz geçiþi yoktur. b. Regülatör çýkýþ vanasý hafifçe açýlýr. c. Slam-shut mekanizmasýnýn kolu yerine takýlarak saat yönünde 1-2° hafifçe çevrilerek gaz geçiþine müsaade edilir.Çýkýþ basýncý gözlenerek sabit ve istenilen deðerde olduðu kontrol edilir. d. Çýkýþ basýncý sabitlendiðinde slam-shut mekanizmasý kurulur. e. Çýkýþ vanasý sonuna kadar yavaþça açýlýr. a. Turn on the valve in the enterance side of the regulator.There will not be gas flow because of the turned off slam-shut mechanism. Slightly turn on the exit valve of the regulator. b. Gas flow is maintained by putting lever of slam-shut mechanism to c. its place and by turning it clockwise slightly one or two degrees. Observe the outlet pressure and check whether it is constant and at the desired value. d. Slam-shut mechanism shall set up when outlet pressure value is stabilised. e. Finally, slowly open outlet valve fully. PERÝYODÝK BAKIMLAR PERIODIC CHECKS Regülatörün fonksiyonlarýnýn uygun þekilde çalýþmasý için periyodik kontrollerin yapýlmasý önerilir. Regülatör kontrolü; It is recommended that the regulator be periodically checked in order to ensure its proper functioning. Checking regulator; a. Regülatör çýkýþ tarafýndaki vana yavaþça kapatýlýr ve çýkýþ basýncý kontrol edilir. Çýkýþ basýncý yavaþça artýyor ve belli bir yerde sabit olarak kalýyorsa bu, vanayý kapatma basýncýndan dolayý oluþmuþtur. a. Slowly close the outlet shut-off valve, and check the output pressure of the pipe between the regulator and the valve. If the system is functioning properly, a slight increase in outlet pressure will be seen at first and then it will be stabilized very soon. b. Öte yandan çýkýþ basýncý sürekli artmaya devam ediyorsa ve herhangi bir deðerde sabit kalmýyorsa bunun nedeni; klape, seat, denge mebraný gibi ekipmanlarýn aþýnmasýndan olabilir. REGÜLATÖRÜN ARIZA DURUMLARI VE ÇÖZÜMLERÝ Bakým kesinlikle regülatörleri bilen kalifiye elemanlarca yapýlmalýdýr. Gerekirse FRS teknik servisiyle de irtibata geçebilirsiniz. Bakým öncesinde regülatör hattýnda gaz olmadýðýndan emin olunuz. Hatta gaz var ise giriþ ve çýkýþ taraflarýndaki vanalardan gazý boþaltýnýz. Bakým zamanýnda bütün kauçuk parçalarýn yenilenmesi önerilir. Bu parçalarý yedek kiti olarak FRS teknik servisinden temin edebilirsiniz. Cihazlarýn bakýmý yapýlýrken ana gövdenin tesisattan sökülmesine gerek yoktur. Maintenance should be carried out only by qualified, skilled personel. If required, please contact FRS Technical Department or authorized dealers. Before carrying out maintenance procedures, make sure that no gas under pressure is trapped in the regulator body. In order to release all gas from the regulator, first close inlet and outlet valves and then release gas from the line by openingthe appropriate vent tap. When carrying out general maintenance, replace all rubber parts, for this purpose, use only the spare parts included in FRS GASs spare parts kit. Maintenance operations do not require removal of valve body BAKIM MAINTENANCE Bakým iþlemleri esnasýnda pade kolaylýkla eriþilir ve diðer regülatörlerden farklý olarak padi yenilemek için regülatörü hattan çýkarmaya veya diyaframý demonte etmeye gerek yoktur. During the maintanence operations the pad is easily accessible and unlike in other regulators, there is no need to remove the regulator from the line or to disaaemble the diaphragm in order to replace the pad. Flanþý kolaylýkla çýkarabilmek ve pad tutucuya kolaylýkla eriþebilmek için özel bir ara çubuðu regülatör sistem çýkýþýna monte edilir. A special spacer has been installed dovnstream of the regulator so that, once the spacer is removed, the outlet flange can also be easily removed for ready acces to the pad-holder. TROUBLESHOOTING AND SOLUTIONS * In case of no gas flowing downstream of regulator, check that; a. Gas is being regularly fed into the regulator, b. Slam-shut valfin kapanmýþ olup olmadýðýný kontrol ediniz. b. The actuator is properly latched (only in models fitted with slamshut valve). b. Seçilen regülatörün istenilen debi miktarýný karþýlayýp karþýlamadýðýný, c. Regülatör yayýnýn kýrýk olup olmadýðýný kontrol ediniz. MAINTENANCE PROCEDURE ATTENTION!!! b. If, on the contrary, outlet pressure continuously increasing, the sysytem is not functioning properly due to improrer valve disc seal. In this case, close the valve located upstream of regulator and carry out maintenance procedures as set out in section. * Regülatörün çýkýþýnda gaz akýþý yok ise; a. Giriþte gaz basýncýnýn olup olmadýðýný, * Regülatörün çýkýþ basýncý istenilen deðerin çok daha altýna düþüyorsa; a. Giriþte gaz basýncýnýn olup olmadýðýný, BAKIM PROSEDÜRÜ DÝKKAT!!! BAKIM DEVREYE ALMA Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator MAINTENANCE ASSEM BLY, INSTALLATION AND COMMISSIONING MONTAJ, KURULUM VE DEVREYE ALMA Aksiyal Akýþlý Yüksek Basýnç Regülatörler / Axial-Flow High Pressure Regulator * In case of gas pressure decreasing on the outlet side of the regulator, check that; a. Sufficient gas is being fed into the regultor, b. Regulator capacity is compatible with desired flow rate, Spacer overall dimensions c. The spring is in good condition or broken. * Regülatörün çýkýþ basýncýnda sürekli bir artýþ söz konusu ise; a. Regülatör seatýnýn ve klapesinin aþýnmýþ olup olmadýðýný, b. Seat ve klapenin temiz olup olmadýðýný, c. Denge mebranýnýn hasara uðrayýp uðramadýðýný kontrol ediniz. * In case of gas pressure decreasing on the outlet side of the regulator or safety devices (relief valve or slam-shut valve) being activated, check that; a. Seal pad or seal are in good condition or worn. b. The seal pad is properly clean as dirt build-up may prevent regular functioning of the valve. c. Balance membrane is in good condition or damaged. DN 25 S 30 40 50 80 40 50 60 DN is referred to the outlet flange of the regulators CAKA CAKA S E R Ý S Ý S E R Ý S Ý 13 frsgaz.com.tr frsgaz.com.tr 14