Yüksek Çıkış Güç Faktörlü Modüler UPS
Transkript
Yüksek Çıkış Güç Faktörlü Modüler UPS
RM Serisi Modüler UPS 50-500 kVA Kesintisiz Güç Kaynağı & Data Center Altyapı Çözümleri Görüntüle Yüksek Çıkış Güç Faktörlü Modüler UPS RM Serisi ailesine göze çarpan güç faktörü ile yeni bir üye... Her biri 50 kVA Modüllerden oluşan kapasitesini 1 MVA kadar arttırılabilen, çift çevrimli, esnek akü konfigürasyonuna sahip, fonksiyonel kullanımı, yük altında modül değiştirme özelliği ile kesintisiz çalışma imkanı veren dev bir UPS sistemidir... 42 Technical Specifications Rated Power / Max. Output Power Power of Each Module Max. Number of UPS Modules RM50-500 50-500 kVA / 50-500 kW 50 kVA 10 GENERAL UPS Type / Technology MTBF / MTTR Output Power Factor Display Parameteres via LCD Smart Features / Smart Eco Mode True Redundancy / [ N+1 ] Protections Troubleshooting Modular Design (Centralized Parallel Architecture) / 3-Level Technology > 200,000 hrs / < 10 mins. 1 Mimic Diagram for Complete System; Indicators for Battery, Rectifier, Inverter, Bypass, Load Status; System Information, Data and Instruction, Current Record Window; Monitoring Main Input, Bypass Input, AC Output Characters, Load Data, Battery Data (Temp, Remaining Time, Capacity, Etc.) Cold Start; AC Restart; Auto Restart / Standard; User Selectable N+1 & N+X Paralleling Options / System Capacity up to 1 MVA/1MW Consistently reliable protection for hardware and software, Sophisticated detection inside the UPS, Abundant event log for future check EPO; Battery Charging & Discharging, Maintenance Circuit Breaker, Generator Statur; Bypass Phase Fault, Fan Fault, Voltage Abnormal Alarms; Manual UPS Shutdown, ETC. EFFICIENCY Overall Efficiency ≥95,5% @ 100% Rated Load Smart Eco Mode Efficiency ≥98,5% @ 100% Rated Load INPUT Rated Voltage 360 / 380 / 400 / 415 VAC 3P + N + GND Voltage Range 204 ~ 305 VAC (load linear decrease to 35%); 305 ~ 485 VAC (full load) Rated Frequency 50 or 60 Hz Frequency Range (Selectable) 40 ~ 70 Hz Power Factor 0.99 THDi ≤ 3% OUTPUT Rated Voltage / Voltage Stability Rated Frequency / Freq. Accuracy Voltage Distortion (THDv) Crest Factor Overload Capability 360 / 380 / 400 / 415 VAC 3P + N + GND / ±1% 50 or 60Hz / ± 0.1% < 1% (Linear Load), < 5% (Non-Linear Load) 3:1 102% - 125% Transfer to Bypass After 10 Mins; 125% - 150% Transfer to Bypass After 1 Mins; >150% Transfer to Bypass After 0.5s. BATTERY Rated Voltage [DC] / Quantity Charger Current ± 240VDC ( ±180VDC; 192VDC; 204VDC; 216VDC; 228VDC; 252VDC ) 30; 32; 34; 36; 38; 40; 42 x 12V/9AH 12A (each power module); Optional Super Charger Module (30A) COMMUNICATION Advanced Communication Remote ON/OFF RS232, RS485, Dry Contacts, SNMP Card, EPO, Generator Interface, LBS (Load Bus Synchronizer) Remote EPO or SNMP over LAN ENVIRONMENT Operating Recommended Operating Storage Temperature Altitute / Relative Humidity Audible Noise 0ºC to 40ºC -40ºC to 70ºC -25ºC to 70ºC ≤ 1000m above sea level; derating power by 1% per 100m between 1000m and 2000m / 0 to 95%, Non-Condensing < 65dB STANDARDS Safety / EMC / LVD / Performance IEC61000-4-2 (ESD); IEC61000-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge); EN62040-2 DIMENSIONS & WEIGHT Module Dimensions (WxDxH) [mm] Module / UPS Net Weight [kg] 442x655x131 32 / 200 UPS Dimensions (WxDxH) [mm] 600x900x2160 UPS Packing Dimensions (WxDxH) 700x970x2160 NECRON ürün özelliklerinde önceden bilgi vermeksizin güncelleme hakkına sahiptir. All specification can be updated by NECRON without notification 43