ME.KAL
Transkript
ME.KAL
KALiBRASYON SERTiFiKASI CERTIFICATE OF CALIBRATION ME.KAL Kalibrasyon Laboratuvar MOdOrlugu Karyagdl Sok. No : 14/1 06690 A.Ayrancl - ANKARA Tel: (312)4419208 Faks : (312) 440 25 38 KIM - Kalite iyile§tirme Merkezi MOh., Dan., Egitim., l~ ve 01$ Tic. Ltd. E-posta medkal@kim-tr.com Web Sitesi www.kim-tr.com Kalibrasyon Laboratuvan f Calibration Laboratory: Kalibrasyon tarihi ve yeri !Dale 24.04.2012 and place of calibration: Kadln Dogum Sertifika Sorumlu OZeAN Model ( Model: PERFECT ERKA S.B. KE<;IOREN EGITiM VE ARA$TIRMA 4055/12 ANKARA kalibrasyon standardlan/Calibration standards Tanlm I Description Model/Model Parametre Test Cihazi (') QA-PT ANEROID Sipari§ no I Order no: Cihaz sahibi I Customer: METRON KS-12/04/3135 Responsible 11040620 Aleti HASTANESI/ of issue and no Seri no f Serial no: Description: imalat~1 I Manufacturer: Kullanllan I E. Ekrem Olcay KU$DEMIR Tansiyon !Dale 24.04.2012 Kalibrasyonu yapan I Calibration done by Cihaz tamml' tarihi ve no'su Servisi used {izlenebilirliklTraceability}: Seri no / Serial no Gegerlik suresi / Due date 14082 Mart 13 Kalibrasyon Metodu I Calibration Method: Kalibrasyonda kullanllan cihazlann (flkl§lafl; NIST (National Institute of Standards) ve/veya NRS (National Reference Standards) taraflndan realize edilmi§ birimler olup, kalibrasyonu yapllan cihazdan allnan bilgiler ile klyaslanml§tlf. OICfum belirsizligi %95 guvenlik seviyesi ve k=2 6rtme faktoru esas ahnarak hesaplanml§tlr. / The outputs of the calibrators which are basic units realized by NIST (National Institute of Standards) and/or NRS (National Reference Standards), compared with measured data. In the calculations of uncertainities confidance level is taken 95% with the coverage factor k=2. Cevre §artlanl Environmental conditions: S!cakllk / Ambient temperature : 23 +/- 2 °C Nem / Humidity : 50 +/- 10 % Sicakhk dengelenme zaman I I Temp. stabilization time : 30 dak/min Tavsiye edilen gelecek kalibrasyon tarihi IRecommended recalibration before: 24.04.2013 * Test cihazlnln izlenebilirligi MEDKAL- KiM Ltd. $ti. uzerinden PTS (Physikalisch Technische Bundesanstalt)'e uzanmaktadlr. / The test equipments are traceable by MEDKAL-KiM Ltd. $ti. through PTB (Physikalisch T€chnische Bundesanstalt). ** Muhursuz ve imi:aslz sertifikalar gegersizdir & Bu sertifika Laboratuvanmlzln onaYI olmakslzln r;ogaltllamaz. / Certificates without signature and seal are not valid & This certificate may not be reproduced without p3rmission of our laboratory. KL.F.01/09 Rev.tJo: 03 Sayfa 1/2 Olf;ilm Raporu f Measurement Report KS·12/04/3135 Marka: Manometre Model: ERKA Testi I Manometer PERFECT ANEROID Seri No: 11040620 Test ~~i~i;';;~~ii.~i~;~kii.iji>!i .: <i.ike •••..ii.iiiSi2ii~i •• ~i¥i'~\l~~'" MEDKAL - KiM Mlih., .Re~f\l~i;e •• Oiitliien¥ ••••• \!"~eii~Hi~•• 30 mmHg 31,0 mmHg 1,0 mmHg 0,395 50 mmHg 51,0 mmHg 1,0 mmHg 0,628 70 mmHg 71,0 mmHg 1,0 mmHg 0,864 90 mmHg 91,0 mmHg 1,0 mmHg 1,102 1,340 110 mmHg 111,0 mmHg 1,0 mmHg 120 mmHg 121,0 mmHg 1,0 mmHg 1,459 130 mmHg 131,0 mmHg 1,0 mmHg 1,579 150 mmHg 151,5 mmHg 1,5 mmHg 1,823 200 mmHg 201,5 mmHg 1,5 mmHg 2,421 250 mmHg 251,5 mmHg 1,5 mmHg 3,019 300 mmH 301,5 mmH 1,5 mmH 3,617 Dan., if; ve OIl} lif;. Ltd. Sayfa 2/2
Benzer belgeler
MKRKEl KOVLERE HizMET G6`flJRM£ BIHLiGi IHALE Y6~ET!HJi
!.1llARENiNADl:T,C,BiTLis VALiLIOt-ME,RKL.Z KC)'Yf ,ERE HiL~v{[:'UOTORM E niRI ,i(~i HA~K.A!\'U(~1 2- Adre~i, Telefon ve- tllks nUmlll'IlSI ; Ta~ l'hhall~sl-1:lHlill Vn.filig,J lliHditlll'1 T{on:J2...
DetaylıCoolflex HF Halogen Free Test Raporu
l(\l rclort kprcseil!s onl, tcfiad saillpla(s), and shall not
Detaylı