AutroSafe Manual call-point with SelfVerify® - BF-300
Transkript
AutroSafe Manual call-point with SelfVerify® - BF-300
AutroSafe Manual call-point with SelfVerify® - BF-300 Features • Addressable • Max. 3-second response time • The call-point comprises a built-in indicator (LED) • Can be tested by means of a special test-key • With the SelfVerify®-functions • Short-circuit isolator in each call-point • Automatic addressing • Proven technology • Intended for connection to Autronica’s interactive alarm system, AutroSafe • Designed to meet the requirement of the major maritime classification societies Applications BF-300 is a manual call-point for indoor use. The call-point is designed for use with Autronica’s interactive fire alarm system, AutroSafe, and comprises the SelfVerify® function. This function ensures the highest grade of reliability and the lowest degree of manual testing because all units comprising this function are automatically self-tested once every 24 hours. Optionally there is a BF-300M version, which is delivered with a metal box fitted with two cable glands. This version is made for applications where a higher degree of weather protection is required. There are also manual call-points for use in hazardous area zone 2. The BF-300M/N has a metal mounting box with two cable glands. The BF-500/N has a standard plastic mounting box. They must be connected to the BSD-310/N loop driver, but do not require an isolator/barrier unit. The call-point must be installed according to local regulations, which normally means along escape routes, landings and exits. Principle Break glass operation, releasing alarm switch. Reset when a new glass is mounted. “SelfVerify®”, the call-point’s ability to initiate alarms is regularly checked. 116-P-BF300/CE - Rev. G, 2006-09-07 Versions • BF-300 • BF-300M* • BF-500/EX* • BF-300M/N* • BF-500/N Manual call-point with SelfVerify® Manual call-point with SelfVerify®, with metal mounting box and cable glands Manual call-point with SelfVerify®. EExia-version for use in all zones Manual call-point with SelfVerify®. Eexn-version for use in zone 2 only Manual call-point with SelfVerify®. Eexn-version for use in zone 2 only * See separate data sheet Technical Specifications Weight Material Colour Voltage Current consumption Stand by: Alarm (LED): Environm. requirement Degree of protection Working temperature Storage temperature Humidity (non-condensing) Maintenance Service Approvals Cable wire Certificate for BF-500/N 108 g Thermo plastic Red 10 - 27V DC 0,3mA 6mA EN-54 IP 24 - 30 to + 50°C - 55 to + 70°C Max. 95% RH Replace broken glass Replace if faulty See separate documentation 2 Maximum 2,5 mm NEMKO 03ATEX217X Protecting life, environment and property... Manual call-point with SelfVerify® - BF-300 Connections Order Numbers Order number BF-300 BF-300/GB Description Call-point BF-300 with labels according to BS5839 part 2 Call-point certified for use in zone 2. BF-300/GB without mounting box Manual Call-point, yellow BF-300, Swedish label BF-500/N BF-300/GB1 BF-300/Y1 BF-300/S 1 2 3 4 BNB-300 1. Pos (+) in 2. Pos (+) out 3. Neg (-) in 4. Neg (-) out 5. Internal connection 6. Internal connection Dimensions Dimensions: HxWxD = 87x87x39mm Open mounting 20 Flush mounting 19 Fig. 1 Fig. 1 Cable knock-outs Ø10mm Fig. 2 60 Fig. 3 Standard mounting box BFW-1 Flush mounting box Fig. 1: Manual call-point Fig. 2: Standard mounting box BFW-1 Fig. 3: Box for flush mounting Autronica Fire and Security AS Fire and Security, Trondheim, Norway. Phone: + 47 73 58 25 00, fax: + 47 73 58 25 01. Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Visit Autronica Fire and Security's Web site: www.autronicafire.com 5 6 Manual call point with SelfVerify, weatherproof - BF-510WP-H Interactive fire detection systems Product datasheet Features For outdoor use Weatherproof Degree of protection: IP52 (55) With SelfVerify function for reduced maintenance/testing and increased reliability Maximum 3-second response time Automatic addressing Designed to meet the requirement of the major maritime classification societies Approved according to EN 54-11 and EN 54-17 Applications BF-510WP-H is a manual call point for outdoor use. The call point has been designed for use with Autronica’s interactive fire detection systems, and comprises the SelfVerify function. This function ensures the highest grade of reliability and the lowest degree of manual testing, because all units comprising this function are automatically self-tested once every 24 hours. The high IP degree of the enclosure makes the call point suitable for outdoor applications. The call point must be installed according to local regulations, which normally means along escape routes, landings and exits. Technical specifications Weight 200 g Material ABS Colour Red Operating method Voltage 16 – 26 VDC Press white plastic element. Resettable by means of Current consumption Stand by: 0,3mA dedicated test key. Optional: Break glass element. Resettable by mounting new glass element. SelfVerify: the call point’s ability to initiate alarm is regularly checked. Installation The backbox is provided with three knockouts for M20 cable glands, two at the top and one at the bottom. Versions BF-300V2* Manual call point with SelfVerify - standard version BF-510WP-H Manual call point with SelfVerify, weatherproof – high current version Maximum current on detection loop 400mA Environm. requirement EN 54 CPD certificate 0333-CPD-075245 Degree of protection IP55 with cover IP52 without cover Working temperature - 40 to + 70°C Storage temperature - 55 to + 70°C Cable inlets 3 x M20 Service Replace if faulty Approvals See website *see separate datasheet 116-P-BF510WPH/CGB, Rev. A, 2010-06-23 Protecting life, environment and property… Manual call point with SelfVerify, weatherproof - BF-510WP-H Part number 116-BF-510WP-H Description Manual call point with SelfVerify. High current, weatherproof Accessories 116-4860-011.0100 Polycarbonate cover (IP55) 116-6571-011.1920 Cable gland M20x1,5 116-6531-006.1920 Gland back nut M20x1,5 116-BFG-3 Glass element Connections Dimensions AUTRONICA FIRE AND SECURITY AS Head office, NO-7483 Trondheim, Norway Tel: +47 73 58 25 00, fax: +47 73 58 25 01, e-mail: info@autronicafire.no Oil and Gas division, Stavanger, Norway Tel: +47 51 84 09 00, fax: +47 51 84 09 99 Maritime division, Spikkestad, Norway Tel: +47 31 29 55 00, fax: +47 31 29 55 01 Visit Autronica Fire and Security AS’ website: www.autronicafire.com