llEsLm - TTAF Elektronik
Transkript
llEsLm - TTAF Elektronik
ffi 4m;l llEsLm TEST REPORT IP 68 I IP 68 rESr RAPORU DEGREES OF PROTECTTON PROVIDED By ENCLOSURES ( tp CODE) MAHFAZALARLA sadurunru KaRUMA oeneceteni 1i, xooul ' Report Reference No (Referans N u marast)...... LVD-2015230 Tested by (+ signature) (Deneyi gergeklegtiren).......... Ergin KOQAK Approved by (+ signature) (Onaylayan) Engin URULU Date of issue (Dttzenleme tarihi)... 201 5-08-1 9 Totaf number of pages (Toplam Sayfa 16 Pages Testing Laboratory (Test Laboratuvan)... Esim Test Hizmetleri A.g. . Address (Adres)....... I Sayfa TOSB-Taysad O.S.B. 6. Cadde No:1/2 41480 Qayrrova / Kocaeli/ TURKEY Applicant's name (Bagvuran ismi).. TTAF Elektronik San. Tic. Ltd. $ti. Address (Adres) Kavakh Mah. lstanbulCad. No:21 .. I TARKYE 34520 BeylikdUzU / lstanbul / TURKEY I TARKIYE (standart)... ... ... ... ... : IEC 60529:2001 , EN 60529:1991 + A1 :2000 Test procedure (Deney prosed1ril)... .: lP68 Test procedure (1P68 Test Prosed(irii) standard Non-standard test method (Standart olmayan test ........ ..: NIA (YOK) metodu)... Test Report Form No (Deney Rapor Form No).... TRF Originator (TRF ...............: Sahibi)... : NIA (YOK) ESIM Date (s) of performance of tests (ArIin testlerinin yapilry tarihleri). 2A$.08:4 -2015.0817 General remarks: (Agklamalar) The test results presented in this report relate only to the object tested. (Raporda yer alan sonuglar sadece test edilen cihaz kapsamaktadtr.) Test item description (Deneye tabi tutulan cihaz)......... Water proof T type connector (T tipi su gegirmez Trade Mark (Ticari Marka)......... TTAF Manufacturer TTAF konnektdr) (U retici).. Modef/Type reference (Model)... WPO3 240Vac, 15 A TRF No. ESM1000 iI .*-Fo I I I L_,, Esfrrm G: TestHizmetleftSifirayiveTicaretA.g. ross-rnvs,llo&. san.Bbrsesi o. Cad. No:172 llyasbeyTV.p-%{07826ZCayrrova/KOCAELI Tic. Sic.'ltl6: 13287 Tet: ( 0262 ) 658 30 63 : 135 484 345 179 OZSB Mersis No I Esrt Page 2 of 16 Ref. No.: LVD-2015230 @ ESfM Test Hizmefleri San. ve Tic. rnO A.g., Kocaeli, Tiirkiye It is prohibited to change-any and all versions of th-is document inany mannerwhatsoever. In case of a confrict between the electronic version (e'g' PDF fite) and the originai paper version p.ouioeio ov EstM, the ratter wilr prevair. ESIM Test Hizmetleri San' v-e Tic' A'$' disctaim tiability for any direct, indirect,,consequential or incidental result from the use of the informatiori or oata, ori.om itte inauirity to rise lhe information or data contained damages that mayl in this document. Il'""ril:li:TH:1,'l!"",':[""f.#il":*t"|3,tJffiili:1;::lg,:Hffi"i its entiretv and provided with the copyrisht notice, Pargalara boltinmesi de dahit fakat bununla stnrrh kalmamak tizere, her ne gekirde orursa orsun, herhangi bir bigimde igbu bergenin herhangi bir ve biltttn versivo,nlartntn aeo'sir;nisi ;;r"iiir,tay pDF dosyaa) ite Esrvt brafindan kadttversiyon arasnda bir ihtitafin mevciiniiir^"iiourumunda temin editen i:?ft!!i";i;ii;"rk ise ikincisi gegerti otacakfir. ESIM Test Hizmetleri s"n:,y, Tic, kullantlamamaandan kavnaklanan belselin 4$.igglr nerningiii iioiia"n, iginde ihtiva editmekte olan bitgiterin veya verilerin kullarulmasndan veva ttot"vt,, ortaya gtkan ytikijmrtiri)krei kabut etmemektedir- ;f;;::::1:,::;''#T,:i,':E|,:#lT:,!;':;:;:##;'::;:"tr;,tetir TRF No. ESM1000 irii i"illiii hakkr bitdirimi, deuistirme vasaQt temin editmek suretiyte itetitebitir, Esfrmo G nr*i11ffi Test Hizmefleri$nayi ve Ticaret A.g, Page 3 of 16 Ref. No.: LVD-2015230 IE sil|tm G5 Test Speeificafions (Test Bitgis}: TEST 1 IP6X: Degrees of protection against solid foreign objects indicated by the first characteristic numeral The test is made using a dust chamber incorporating the basic principles whereby the powder circulation pump may be replaced by other means suitable to maintain the talcum powder in suspension in a closed test chamber. The talcum powder used shall be able to pass through a square-meshed sieve the nominal wire diameter of which is 50pm and the nominal width of gap a between wires 75pm' The amount of talcum powder to be used is 2kg per cubic metre of the test chamber vorume. rt shail not have been used for more than 20 tests. For lP6X enclosures is of necessity in Gategory Gategory 1: Enclosures where the normal 1 working cycle of the equipment causes reductions in air pressure within the enclosure below that of the surrounding air, for example, due to thermal cycling effects Gategory 1 enclosures: The enclosure under test is supported inside the test chamber and the pressure inside the enclosure is maintained below the surrounding atmospheric pressure by a vacuum pump. The suction connection shall be made to a hole specially provided for this test. lf not othenrise specified in the relevant product standard, this hole shall be in the vicinity of the vulnerable parts. lf it is impracticable to make a special hole, the suction connection shall be made to the cable inlet hole' lf there are other holes (for example, more cable inlet holes or drain-holes) these shall be treated as intended for normal use on site. The object of the test is to draw into the enclosure, by means of depression, a volume of air g0 times the volume of the sample enclosure tested without exceeding the extraction rate of 60 volumes per hour' In no event shall the depression exceed 2 kPa(20 mbar) on the manometer shown in figure 1. lf an extraction rate of 40 to 60 volumes per hour is obtained the duration of the test is 2 h. lf' with a maximum depression of 2 kPa (20 mbar), the extraction rate is less than 40 volumes per hour' the test is continued until 80 volumes have been drawn through, or a period of g h has elapsed. I["r::?t""tion is satisfactory if no deposit of dust is observabte inside the enctosure at the end of TRF No. ESMIOOO ;- i.-,:ii ii ;,'j . ij-5 lEsilmG) Page 4 of 16 Ref. No.: LVD-2015230 TEST 1 IP6X: Yabanct kail cisimlere kargt birinci karakteristik rakamla gt)sterilen koruma dereceleri; Deney kapah bir deney hiicresinde talk pudrastnt asktda tutan uygun bir dazente, toz sirkhlasyon pompasnn de1igtirilebirdiQi bir toz hiicresi kuttanrtarak yaprttr. Kullanilan talk pudrau' anma tel gapt 501tm ve tetler arastndaki anma genigliqi Tspm otan kare bigiminde drgtlii bir silzgegten gegebilmetidir. Deney hiicresi hacminin metre kttpti bagrna ku1an,masr gereken tatk pudrau miktan 2kg dtr. Tatk pudrast 20 den fazta deneyde kurtanrtmamry otmahdrr. IPGX igin mahfaza kategori I otmak zorundadtr. Kategori 1: Donantmtn normal galryma gevriminden, ornek olarak igindeki hava bastnctntn bu havayt kugatan basnctn rctl qevrim etkilerinden dolayt mahfaza alttna dtigmesine y'l agan mahfazalar Kategori I mahfazalart: Deneyden gegiriten mahfaza deney hiicresi igine yerlegtirilir ve mahfaza igindeki baang bir vakum pompaayla kugatan atmosfer basrnctnrn alttnda tututur. Emme ba1lanttsr, bu deney igin sa*anmry 6zet bir deliQe yapilmahdr' ilgili iirttn standardrnda bagkaca betirtilmemigse, bu delik kotayca aEtabiten b*ttjmlerin civannda olmatdr. ozel bir detik agmak pratik olarak mumkiln delitse, emme baillantrsr kabto girig detiQine yapilmahdr. Bagka delikler varsa (6rnek olarak, daha fazta kabto girig detikteri veya bogattma detikreri) bu detikter normar kullanma alant nda amagtandet gibi igteme tdbi tututmatrdrr. Bu deneyin amad' saatte 60 hacimtik bogaltma htzrnr agmadan, deneyden gegiriren numune mahfaza hacminin' 80 kafi hava hacmini, basktyoluyta mahfaza igine gekmektir. Higbirdurumda, gekit 1,de g8steriten manometre tjzerindekibask 2 kpa,y (20 mbar) agmamaldtr. saaffe 40-60 hacimtik bir bogattma hzr elde edilirse, deney silresi 2 saat olmahdrr. Maksimum 2 kPa'ltk (20 mbar) baskt ite bogattma fuzr saatte 40 hacimden az ise, g0 hacimtik hava igeri gekilmig oluncaya kadar veya g saattik silre geginceye kadar deneye devam editir Deney sonunda mahfaza iginde higbir toz birikintisi g,zlenmiyorsa koruma isteniten yetertiktedir TRF No. ESMIOOO Hsfram GJ Test Hizmetleri Salrayi ve Ticaret A,$. TOSB-TAYSAD 99(5;;.Slrsesi llyasbey V.Di54 Tic. Sic. t1X yipfr.: Mdreis-No: 6. Cad. No:1/z A?61 Qayrrova/KOCAELI Tet: ( c2O2 ) 658 30 63 135 404 34S 178.9)5R O-02 G5 Page 5 of 16 Ref. No.: LVD-2015230 Test Speeifications (Test Bitgisi): TEST 2 IPXS: Degrees of protection against water indicated by the second characteristic numeral. Unless there is a relevant product standard, the test conditions are subject to agreement manufacturer and user, between they shall b" ror" severe than those pr"""rin"a -bui rpxz take account of the condition and they sharl tnlt ttre enclosure *irr u" rmmersed "1 in actuar use. "oniinuor"ry IPXT: Protected against th.e effects of temporary immersion in water. Ingress of water in quantities causing :,ffi':liXT:"Jlfi[1".:ff,l"XXi:':;;'d";T;;';"1i"",,1J'i" t",ipo,a.irv'i;;";J;t;;;";;;il-, Ifi.',,j",l:?'#::f;,:J.::TffhY;11,ffifi'J:iffiHs:1i"":1,:;LTr in its service position as speciried a) with a heisht less than 850 mm is tocated 1000 mm betow the Iffij:y$1f""il:;l.""closure b) The highest point of enclosures with a height equal to or greater than 850 mm is located 150 mm below the surface of the water. c) The duration of the test is 30 min. d) The water temperature does not differ from that of the equipment by more than sK. Howevern a modified requirement may be specified in the relevant-pioduct sianaaro if the tests are to be made when the equipment is energized parts in motion I "nJio.it" rESr 2 \PXB: suya kary ikinci karakteristik rakamta glsteriren koruma derecereri ilgili tirun standardr m,evcut delitse, deney ga,rtlart imalatgt ve kulhnct arasndaki mutabakata g6re saQlantr, ilf*I::,::xiil ''a:,"i"":;!!:t;E!:u ;!;,ii.r* i:rlii,,ii"',,JT,)i'"iil", IPXT: ,unriun; dnsit suya gegici daldrrma etkiterine kargr koruma, Mahfaza basrncrn ve srirenin standard gafttannda suya gegici olarak daldnld$rnda zararlr etkitere seoef otacak mixta,rniaa- iu girigi mtimk(1n olmamamtdtr. ?;i;{r;f:e'Jiy Ei:lT:;ii:nacak bisimde mahraza, imatatst tararrndan be,tirtiten satryma konumunda suya mm'den az otan mahrazatarrn en att noktasr su yiizey,inden 1000 mm asaQtda 'r|f;:!lfJf:0 a) b) c) :!:;,!:t;;::ilmi esit veva daha biiviik mahrazatarrn en yuksek noktasr su ytizeyinden 150 mm Deney srjresl 30 dakikadr. gi ite donani m si caktisi ni n farki s K'dan dahiz fazta otmamati di r. Bununta ti,aium6ri hareket natnde hatinde vaoi livorsa tivorse degistirilmis'kuratt rtanic,,,,,"::ri!:,:!iiiyigi?q." .n"/y"v?. otduottnrta deneyler rrpnavto, oldugunda vapi itgiiiirtri stanaardi nda betirtiteb;l;.'un"' ,,0,,!/", i:r:;f#" TRF No. ESM100O Ref. No.: LVD-2015230 Page 6 of 16 sllllnl G) Acceptance conditions (Kabut garttartt After testing with the appropriate requirements the enclosure shall be inspected for ingress of water. It is the responsibility of the relevant technical committee to specify the amount of water which may be allowed to enter the enclosure and the details of a dielectric strength test, if any. In general, if any water is entered, it shall not: r Be sufficient to interfere with the correct operation of the equipment or impair safety; Deposit on insulation parts where it could lead to tracking along the creepage distances; Reach rive parts or windings not designed to operate when wet; Accumulate near the cable end or enter the cable if any; lf the enclosure is provided with drain-holes, it should be proved by inspection that any water which enters does not accumulate ant that it drains away without doing any harm to the equipment. For enclosures without drain-holes the relevant product standart shall specify the acceptance conditions if water can accumulate to reach live parts. ' o . Mahfaza uygun olan deneylerden gegirildikten sonra su girigi olup otmadrQt gLztenir. Y#fH;,f:ffi':{;;'l:;;:i,:!"su.miktannr G e nel I i kle h e rh a c ve varsa, dietektik davanrm deneyi aynnhtannt betirtemek itgiti ng i bi r su glrmigse; Donanrmrn hatastz gatrymasrnr olumsuz yonde etkitemeye veya guventiQini bozmaya neden olmamalt: ' [ir';l:":i;::#votu uzuntuktafl bovunca yatftkan b6tiimter tizerinderyilzeyset kasaQa yot agabitecek c lslak gartlarda galrymak igin tasarrmlanmayan gerilimli b6rtimtere veya sargilara erigmemeti; ' Kablo ugranntn yahnrnda topranmamatr veya varsa kabroya girmemetidir. Mahfazada bogaltma detikteri giren suy.un birikmediQi ve donanrma herhangi .butunu.rsa, bir zarar vermeden mahfazadan dryan qktgr g6zte yapilan m-uayeneyte kanfttanmitdrr. Bogaltma delikleri bulunmayan mahfazalarda, ilgiti iiriin standardt suyun grtritimti b6tiimtere ulagmak uzere toplanrp toplanmayacaQna ait Kabut gaftlartnt betirtmetidir. TRF No. ESM1000 .s" I rj;:; ,ESilMO Page 7 of 16 Ref. No.: LVD-2015230 llt a rl |"-"* i r"-"' lt--l tiF--L--L-3 Air flouy srstEr iooi Vgcr$m pump t:::::i ekculation pump or 6ther suitrblEfirosns ts:msintnln th6 tatcum Fqwdcr in **p*r*ion iEC.::dfiltr Figure 1 - Test device to verify protection against dust (dust chamber) $ekil 1 - Toza Karg Korumay Dolrutamak igin Deney Dtrzeni (toz hticresi) TRF No. ESM1000 Esfrnn GJ liE,silmCp Page 8 of 16 Ref. No.: LVD-2015230 i,.-,". r,',: ;li=i'.' *:,,i 1;_..;; ('::-," Q TRF No. ESM1000 Ttst l{i;rriiiii:ri T{,:: il. i,; r=.r.YSrtrD i ;$,,,.1: ffib i' ;,"1, i j1l ;r $;+vi lqve :s ! )rb"EiJ.: i.\ -i'icai;l r.:. C r:.i i; ; ;11;1/I; .: /a. ,;,'". ,:.:tn : a.$" :il. iir ; I lZ 1; :l{ Im G) Page 9 of 16 Ref. No.: LVD-2015230 Resufts(So nuglar): TEST 1: lP6X First Gharacteristic Numeral (Bkinci Karakteristik Rakam) Dust Tight (Toza Kary Tamamen Korumat PASS (BAgARtLt) ( SEE PHOTOS / Resm/ere Bakntz I TEST 2: lPX8 Second Characteristic Numeral (lkinci Karakteristik Rakam) Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7. The test conditions have been subject to agreement with the manufacturer.The enclosure of test item was with a height less than 850 mm, that's why it was located 1100 mm below the surface of the water.The duration of test was 45min. Any water have not observed. (Mahfaza imalatq ve kullanrcr arastnda saQlanan, ancak 7 rakamtndan daha aQr gartlarda suya siirekli olarak daldtrrldrQrnda zararlr etkilere sebep otacak miktarlarda su girigi mA mkil n olm am ah d r r. lmalatg ile saQtanan anlagmayla yhksekliQi 850 mm'den az otdugu igin tjrtjn(jn en att noktasryla su y1zeyi arast 1100mm braklmryilr.Deney srjresi 45 dakika olarak ayarlanmryfir. Herhangi bir su girigi g1zlemlenmemigtir.) TRF No. ESM1000 ffisliii',il: ffi-9 Test l"!tzmetleri fiai'iayi ve T!earet A"g" TCIS B -TAYSAD g4<.€r,.ti ot ses i 6. Ce d. r,j c. 7Z lly sb;y v.n. g$otr,iiJir;oy" r,."rl<rre - i:,..i ';jc.:;;.:. ,'r<{g.A- -irr''i,,;,,;2 ir,r - .', } il : 1 PASS (BAgARtLt) ( SEE PHOTOS / Restm/ere Baknrz I Ref. No.: LVD-2015230 Page 10 of 16 Dust Test Equipment 130X90X9Ocm (Toz Kabini) lmmersion Tank (Daldrma Tankt) TRF No. ESMIOOO EsimGJ I::l liry*reri Saynyire Ticaret A.$. ilri"3g"Ti@;iii+:;*,',:*1ru EsfrnrGl Ref. No.: LVD-2015230 frmG) Page 1'l of 16 Test photos (Iesf fotoQraftan) : TRF No. ESMlOOO 'rQ ):'li? i'.i i Ref. No.: TRF No. ESMlOOO '--? //z;t-(//'" lffisrr& Page 13 of 16 Ref. No.: LVD-20'15230 : E € € €: € ,=1 TRF No. ESM1000 ,1 L/q > -/' rmG) Ref. No.: LVD-2015230 TRF No. ESM1000 iEsilrmG> Page 14 of 16 ffimi}fisft #J Test Hizmefler! $cnilri! r ;z il;B;?I,T", ;i ;' :,:; ;:, ; W Wii.r./'J;liyitlt, i i:!: : "U fr,J: i SEqLJ Ref. No.: LVD-2015230 TRF No. ESM1000 Page 15 of 16 ffis* rs.il f.eJ EstlnO Ref. No.: LVD-2015230 Page 16 of 16 ffissrffia = :,-lj :'l .:: l l l TRF No. ESM1000