auto dismanteling
Transkript
auto dismanteling
Internal Use Only http://biz.lgservice.com System SVC MANUAL MODEL: AH Series CAUTION Before servicing the unit, read the safety precautions in general SVC manual. Only for authorized service personnel. AWHP Service Manual TABLE OF CONTENTS Safety Precaution Part 1 : General Information 1. Model Information 2. External Appearance Part 2 : Features & Controls 1. List of Function 2. Features 3. Test Run Part 3 :Replacement 1. Replacement procedure for Compressor 2. Replacement Procedure for INV PCB 3. Caution for Assembling Outdoor Panels after Test Run Part 4 : Trouble Shooting 1. Checking Key Components of Indoor Unit 2. Checking Key Components of Outdoor Unit 3. Self-Diagnosis Feature 4. Trouble Shooting Guide Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -2- LGE Internal Use Only Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. n Be sure to read before installing the product. n Be sure to observe the cautions specified here as they include important items related to safety. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only. n Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING Always ground the product. • There is a risk of electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself. • There is risk of fire or electric shock. Use the correctly rated breaker or fuse. • There is risk of fire or electric shock. Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age. • It may cause product to fall. Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse. • There is risk of fire or electric shock. Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire. • There is risk of fire or electric shock. Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced. • There is risk of fire or electric shock. Never install the outdoor unit on a moving base or a place from where it can fall down. Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker. • Otherwise it can cause electric shock or fire. Install the panel and the cover of control box securely. • There is risk of fire or electric shock due to dust , water etc. For installation, removal or reinstall , always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. When the product is soaked (flooded or submerged) in water , contact an Authorized Service Center for repair before using it again. • The falling outdoor unit can cause • There is risk of fire or eletric shock. damage or injury or even death of a person. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- LGE Internal Use Only Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. • Improper or loose connections can cause heat generation or fire. In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work. • An charged capacitor can cause electrical shock. Be cautious when unpacking and installing the product. • Sharp edges could cause injury. Especially careful on the product edges and the fins on the heat exchanger. Be cautious that water could not be poured to the product directly. • There is risk of fire, electric shock, or product damage. Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit. • This could result in personal injury and product damage. Do not plug or unplug the power supply plug to turn the unit ON/OFF . • There is risk of fire or electric shock. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags. • Children may play with them and cause injury. When installing the unit, use the installation kit provided with the product. • Otherwise the unit may fall and cause severe injury. Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely. • Dirty, loose or broken power plug can cause electric shock or fire. Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment. • The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire. If strange sounds, smell or smoke comes from product. Immediately turn the breaker off or disconnect the power supply cable. • There is risk of physical injury, elec- • There is risk of electric shock or tric shock, or product failure. fire. Turn the main power off and unplug the unit when cleaning or repairing the product. • There is risk of electric shock. Take care to ensure that power cable could not be pulled out or damaged during operation. • There is risk of fire or electric shock. When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker. • There is risk of product damage or failure, or unintended operation. Do not place ANYTHING on the power cable. • There is risk of fire or electric shock. Wen flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Special warning about no operation for long-time • Do not use the telephone or turn switches on or off. There is risk of explosion or fire. • If the product is not used for long time, we strongly recommend NOT TO SWITCH OFF THE POWER SUPPLY to the product. • If power is not supplied, some special product-protecting actions (such as water pump anti-locking) will not performed. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- LGE Internal Use Only Safety Precautions CAUTION Two or more people must lift and transport the product. • Avoid personal injury. Keep level even when installing the product. • To avoid vibration or noise. Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a customer's product, not a precision refrigeration system. • There is risk of damage or loss of property. Do not step on or put anyting on the product. (outdoor units) Do not install the product where it will be exposed to sea wind (salt spray) directly. • It may cause corrosion on the product. Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods. • It may cause a problem for your neighbors and hence dispute. Do not block the inlet or outlet of air flow. • It may cause product failure. Do not insert hands or other objects through the air inlet or outlet while the product is operating. • There is risk of personal injury and failure of product. • There are sharp and moving parts that could cause personal injury. If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas. Do not mix air or gas other than the specified refrigerant used in the system . • The refrigernat gas can cause frostbite (cold burn) Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards. Install the drain hose to ensure that the condensed water is drained away properly. • A bad connection may cause water leakage. Always check for gas (refrigerant) leakage after installation or repair of product. • Low refrigerant levels may cause failure of product. Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc . • There is risk of fire, electric shock, or damage to the plastic parts of the product. Be cautious when unpacking and installing the product. • Sharp edges could cause injury. If the refrigerant gas leaks during the installation, ventilate the area immediately. • If air enters the refrigerant system, • Otherwise it can be harmfull for an excessively high pressure your health. results, causing equipment damage or injury. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. • There is risk of fire or product failure. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire. • They may burn or explode. LGE Internal Use Only Safety Precautions If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. • The chemicals in batteries could cause burns or other health hazards. Do not expose your skin or kids or plants to the cool or hot air draft. • This could harm to your health. Do not drink the water drained from the product. • It is not sanitary and could cause serious health issues. Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height. • Be careful and avoid personal injury. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -6- LGE Internal Use Only Part 1 General Information 1. Model Names .................................................................11 1.1 Indoor Unit .............................................................11 1.2 Outdoor Unit ..........................................................11 2. External Appearance.....................................................12 2.1 Indoor Unit .............................................................12 2.2 Outdoor Unit ..........................................................13 3. Combination of Outdoor Units .....................................14 4. Nomenclature.................................................................15 4.1 Indoor Unit .............................................................15 4.2 Outdoor Unit ..........................................................15 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -7- LGE Internal Use Only Model Information 1. Model Information With advanced inverter technology, is suitable for applications like under floor heating, under floor cooling, and hot water generation. By Interfacing to various accessories user can customize the range of the application. In this chapter, general information of is presented to identify the installation procedure. Before beginning installation, read this chapter carefully and find helpful information on installation. 1. Model Information Model number nomenclature A H — W 0 9 6 A 0 Series Number Chassis Name Electrical ratings 6 : 1 phase 220-240V AC 50Hz 8 : 3 phase 380-415V AC 50Hz Heating Capacity (kW) 09 : 9kW 12 : 12kW 14 : 14kW 16 : 16kW Model Type W : Inverter Heat Pump H : Heat Pump Classification N : Indoor Unit U : Outdoor Unit –– : Set Air-to-Water Heat Pump for R410A A H N W 0 9 A 0 6 A 0 Series Number Chassis Name Heater Capacity (kW) 06 : 6kW 09 : 9kW Heater Electrical ratings 6 : 1 phase 220-240V AC 50Hz 8 : 3 phase 380-415V AC 50Hz A : 3 phase 220V AC 50Hz Heating Capacity (kW) 09 : 9kW 12 : 12kW 14 : 14kW 16 : 16kW Model Type W : Inverter Heat Pump H : Heat Pump Classification N : Indoor Unit U : Outdoor Unit — : Set Air-to-Water Heat Pump for R410A Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -8- LGE Internal Use Only Model Information Model name and related information Model Name Outdoor Unit AHUW096A1 Indoor Unit Built-In Electric Heater(k W) AHNW09604A1 4(2+2) AHNW09606A1 6(3+3) AHNW09A06A1 6(2+2+2) 3N~220V 50Hz AHNW09806A1 6(2+2+2) 3N~380-415V 50Hz Power Source (Electric Heater) Power Source (Unit) 1~ 220-240V 50Hz 1~ 220-240V 50Hz *1 : tested under Eurovent Heating condition (water temperature 30°C ’ 35°C at outdoor ambient temperature 7°C / 6°C) *2 : tested under Eurovent Cooling condition (water temperature 23°C ’ 18°C at outdoor ambient temperature 35°C / 24°C) Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes -9- LGE Internal Use Only Model Information 2. Specification Indoor Indoor Units AHNW09604A1 AHNW09606A1 AHNW09A06A1 AHNW09806A1 Combination Outdoor Units AHUW096A1 Nominal Power Input Nominal Running Current without Electric Heater Operation Range Cooling(Fan coil unit) (Min.~Max.) Cooling(Under floor) Leaving Water Heating(Fan coil unit or Radiator) Temperature Heating(Under floor) Pump Type Steps of Speed Power Input Water Flowrate Limit Heat Exchanger Type Number of Plate Quantity Expansion Vessel Volume Water Pressure(Max.) Water Pressure(Pre) Strainer Mesh Size Material Electric Heater Type Number of Heating Coil Capacity Combination Operation Heating Steps Power Supply Rated Current Maximum Current(MCA) Water Circuit Safety Valve Entering Side Diameter Leaving Side Diameter Manometer Drain Valve / Fill Valve Shut Off Valve Air Vent Refrigerant Circuit Gas Side Diameter Liquid Side Diameter Dimensions Unit(H x W x D) Packed Unit(H x W x D) Weight Unit (Without water) Packed Unit Sanitary Water Tank Type Heater Capacity Power Supply Power Supply Type Thermal Protector Range Relay Contactor ELB Sensor Adaptor Diameter Accessory Kit MCCB W A °C °C °C °C EA W LPM EA EA liter bar bar mm EA kW Step Ø / V / Hz A A bar inch inch mm(inch) mm(inch) mm mm kg kg kW Ø / V / Hz °C A mm(inch) A 135 0.59 6~30 16~30 15~55℃ ( * * 20~55℃) 15~55℃ ( * * 20~55℃) Canned type for hot water circulation 2 (In Max. / Med. / Min., Min. step is not used) 135 At least 12 Brazed Plate HEX 54 1 8 3 1 1x1 Stainless Steel Sheath Sheath Sheath Sheath 2 2 3 3 2+2 3+3 2+2+2 2+2+2 Automatic Automatic Automatic Automatic 2 2 2 2 1 / 240 / 50 1 / 240 / 50 3 / 220 / 50 3 / 380~415 / 50 16.7 26 16 9 21 33 20 12 3 Male PT 1 Male PT 1 0 0 0 0 15.88 (5/8) 9.52 (3/8) 850 x 490 x 315 1082 x 563 x 375 48 48 52 52 55 55 59 59 Indirect heating(+ Electric heater) Max. 3 1 / 230 / 50 Separated power source Max. 90 Needed 40 12.7 (1/2) LG Supply 32 Note : 1. The specification may be subject to change without prior notice for purpose of improvement. 2. * : This information is given as a guideline about the connection of sanitary water tank 3. ** : This specification is data when electric heater is not used. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 10 - LGE Internal Use Only Model Information Outdoor Outdoor Units Power Supply Maximum Running Current Wiring Connections Cooling Heating For Power Supply (Included Earth) For Connection with Indoor Unit (Included Earth) * Capacity Cooling(A35/W18) Heating(A7W35) * Power Input Cooling(A35/W18) Heating(A7W35) * EER Cooling(A35/W18) COP Heating(A7W35) Heating(A2W35) Heating(A10W35) Heating(A-7W35) Operation Range(Min.~Max.) Cooling Outdoor Temperature Heating Compressor Type Model Quantity Displacement Capacity Compressor Motor Type Quantity Rated Output Refrigerant Type Charge Control Refrigerant Oil Type Charged Volume Heat Exchanger Quantity Rows Columns FPI Fan Type Quantity Air Flow Rate Fan Motor Model Quantity Output Sound Pressure Cooling Level Heating Liquid Piping Type Connection Outer Diameter Gas Piping Type Connection Outer Diameter Piping Length Minimum (Outdoor Unit ~ Standard Indoor Unit) Maximum Height Difference Maximum (Outdoor Unit ~ Indoor Unit) Additional Refrigerant Charge Dimensions Unit(W x H x D) Packed Unit(W x H x D) Weight Unit Packed Unit AHUW096A1 Ø / V / Hz A A 1 / 220-240 / 50 15 15 Number of wires 3 Number of wires 4 kW kW kW kW W/W W/W W/W W/W W/W °C DB °C DB EA cm3/Rev. kW EA W g(oz) cc EA EA EA Fins/inch EA CMM(l/s) EA W dB(A)±3 dB(A)±3 mm(inch) mm(inch) m m m 9.00 9.00 2.65 2.19 3.40 4.10 3.25 4.50 2.76 5~48 -20~30 Hermetic Motor GJT240DAA 1 24 7.28 Brushless 1 1,700 R410A 1,900(67.0) Electronic Expansion Valve FVC68D 900 1 2 38 17 Propeller 1 60(1,000) SIC-72FW-F1124-3 1 124 52 52 Flare 9.52(3/8) Flare 15.88(5/8) 3 7.5 50 30 m 30 950 x 834 x 330 1,140 x 900 x 461 64 69 g/m mm mm kg kg Note : 1. Capacities and power inputs are based on the following conditions: * : Cooling conditions - Indoor Water Temperature 23°C/18°C; Outdoor Air Temperature 35°CDB/24°CWB Heating conditions - Indoor Water Temperature 30°C/35°C; Outdoor Air Temperature 7°CDB/6°CWB Standard piping length 7.5m 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 11 - LGE Internal Use Only External Apprearance 2. External Apprearance 2.1 Outdoor Unit AHUW096A1 2.2 Indoor Unit AHNW09604A1, AHNW09606A1, AHNW09A06A1, AHNW09806A1 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 12 - LGE Internal Use Only Part 2 Features & Controls Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 13 - LGE Internal Use Only List of Function 1. List of Function Category Installation Reliability Convenience Individual control CAC network function Special function kit Others AWHP Function Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller(control panel) Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central controller (Non LGAP) Dry contact Network Soluation(LGAP) PDI(power distribution indicator) PI 485 Zone control CTIE Electro thermostat Remote room temperature sensor (TH8) Anti-Condensation on floor (cooling) Water Pump ON / OFF Control Flow Switch Control Thermostat Interface (230V AC) Thermostat Interface (24V AC) Sanitary Tank Heating Solar-Thermal Interface with Sanitary Tank PHEX Anti-Freezing Control Water Pump Forced Operation Autosetting according to Ambient Temperature Silent Operation Anti-overheating of Water Pipe Emergency Operation AHNW09604A1, AHNW09606A1, AHNW09A06A1, AHNW09806A1 O O O O O O O PQDSA O PQRSTA0 O O O O O O O O O O O O O Notes O : Applied, X : Not applied, – : No relation * TH8 : Refer to 'Chapter 8. Piping Diagram' of 'Part 2. Indoor Unit (Hydro kit)' * Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 14 - LGE Internal Use Only Features 2. Features 1. Summarized Features 1.1 Emergency Control Easy checking of system failure - Slight / Heavy trouble Slight trouble Heavy trouble Emergency operating - Heavey trouble - Electric heater ON - Secure at least heating before A/S 1.2 Easy Setting Feature Inlet water temp. Outlet water temp. Hot water temp. Indoor temp. Solar source temp. Indoor temp. or Water temp. (Optional temp. setting) Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 15 - LGE Internal Use Only Features 1.3 Control Panel • Controller Configuration 1 Display Panel 2 Change Temperature Button 1 3 Silent Mode On / Off Button 4 Mode Selection Button 5 Water Heating Enable / Disable Button 6 ESC Button 7 Direction Button (Up, Down, Left, Right) 2 8 3 9 4 10 10 Temperature Setting Mode Button 5 11 11 Temperature View Mode Button 6 7 12 8 Power Button 9 Function Setting Button 12 Programming Button 13 Set / Clear button 13 • Display Panel Cooling Electric Heater (2) Defrost Heating Water Tank Electric Heater Water-Pipe Anti Freezing Weather-dependent Heating Water Pump Water Tank Disinfection Space Temp. Solar Heating Pump Outdoor Unit Water Inlet Temp. Water Tank Heating Enable / Disable Child Lock Water Outlet Temp. Water Tank Heating (by Heat Pump) Not Available Function Central Controller Silent Mode ON / OFF Slight Trouble Thermostat Water Tank Temp. Heavy Trouble Electric Heater (1) Solar Heating Temp. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 16 - LGE Internal Use Only Features 2. Special Function 2.1 Child Lock Function This function prevents children or others from tampering with the control buttons on the unit. • All the buttons on indoor display panel will blocked. The function is used to restrict children to not to use the AWHP carelessly.(CL is an abbreviated form of Child Lock.) Function Setting Button to enter 1 Press user setting mode. (The segment will be flashed) set / clear button to finish the selection. 2 Press The segment will be disappear. Child Lock, icon and 'CL' will be 3 During displayed during 3 seconds whenever entering any kind of buttons except for view temperature button and setting/clear button . release this setting, pressing 4 Tofunction Setting button until icon flash and then enter setting/clear button. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 17 - LGE Internal Use Only Features 2.2 Sleep Timer Operation • When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the control panel while in appliance operation, the operation of the appliance stops. • While the appliance is on pause, the sleep timer mode cannot be input. 2.3 Timer(On/Off) 2.3.1 On-Timer Operation • When the set time is reached after the time is input by the control panel, the appliance starts to operate. • The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached. • If the appliance is operating at the time set by the timer, the operation continues. 2.3.2 Off-Timer Operation • When the set time is reached after the time is input by the control panel, the appliance stops operating. • The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached. • If the appliance is on pause at the time set by the timer, the pause continues. 2.4 Weekly Program • If necessary, an operator can make an On/Off reservation of the product for a period of one week. - On/Off schedule of operation for a period of One week. • No need to turn the unit On/Off manually during working days. On/Off time is scheduled in micom of the wired remote control. Operation Time Table (Example) Setting Mon Temp. 25°C 25°C Tue Wed Thu 25°C 25°C Fri Sat Sun 25°C On 09:00 08:00 09:00 08:00 09:00 Off 12:00 17:00 12:00 12:00 12:00 Off 2.5 Sanitary Tank Heating Scheduler & Sanitary Tank Heater Scheduler • If necessary, enable or disable of sanitary tank heating or sanitary tank heater can be programmed according to userʼs specific time. • Schedulers are operating everyday. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 18 - LGE Internal Use Only Features 3. System Set-up As is designed to satisfy various installation environment, it is important to set up system correctly. If not configured correctly, improper operation or degrade of performance can be expected. 3.1 DIP Switch Setting Turn off electric power supply before setting DIP switch • Whenever adjusting DIP switch, turn off electric power supply to avoid electric shock. General Information OFF ON 1 2 3 4 5 6 7 8 OFF is selected ON is selected Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 19 - LGE Internal Use Only Features DIP Switch Setting Description Role when central controller is equipped Setting 1 As Master 1 As Slave 2 Indoor unit + Outdoor unit is installed 3 2 Accessory installation information 3 2 3 Emergency operation Level Indoor unit + Outdoor unit + Sanitary water tank is installed Default 1 2 3 Indoor unit + Outdoor unit + Sanitary water tank + Solar thermal system is installed 4 High temperature cycle 4 Low temperature cycle 5 External water pump is NOT installed 4 External water pump installation information 5 External water pump is installed 6 Step 2 capacity is used 5 7 6 Selecting electric heater capacity 7 6 7 Thermostat installation information Step 1 capacity is used 7 Electric heater is not used 8 Thermostat is NOT installed 8 Thermostat is installed Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes 6 - 20 - 8 LGE Internal Use Only Features 3.2 Control Panel Setting Summary Example of Fuction Code Display Function Code Value #1 Value #2 Common Setting • Function Code 01 : Test Run Test run should be performed when additional refrigerant charging is required. To charge the refrigerant, the product must run in Cooling mode. Test run instantly makes the product working in Cooling mode for 18 minutes. Note: • If you press any kind of button during this mode, Test Run mode will be finished. • After running 18 minutes under test run mode, system will automatically turn OFF. • Function Code 02 : Disable 3 minute Delay Factory use only. • Function Code 03 : Remote Air Sensor Connection If user connects remote air sensor to control the product by room air temperature, the connection information should be notified to the product. Note : If remote air sensor is connected but this function code is not set correctly, the product can not be controlled by room air temperature. • Function Code 04 : Celsius/Fahrenheit Switching Temperature is displayed in Celsius or Fahrenheit. • Function Code 05 : Setting Temperature Selection The product can be operated according to air temperature or leaving water temperature. The selection for setting temperature as air temperature or leaving water temperature is determined. Note : Air temperature as setting temperature is ONLY available when Remote Air Sensor Connection is enabled and Function Code 03 is set as 02. • Function Code 06 : Auto Dry Contact This function allows the Dry contact-indoor unit operate under Auto Run mode or Manual mode with remote control panel. • Function Code 07 : Address Setting When Central Controller is installed, address assigning is set by this function. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 21 - LGE Internal Use Only Features Temperature Range Setting • Function Code 11 : Setting Air Temperature in Cooling Mode Determine cooling setting temperature range when air temperature is selected as setting temperature. Only available when remote air temperature sensor is connected • Accessory PQRSTA0 should be installed. • Also, Function Code 03 should be set properly. • Function Code 12 : Setting Leaving Water Temperature in Cooling Mode Determine cooling setting temperature range when leaving water temperature is selected as setting temperature. Water condensation on the floor • While cooling operation, it is very important to keep leaving water temperature higher than 16°C. Otherwise, dew condensation can be occurred on the floor. • If floor is in humid environment, do not set leaving water temperature below 18 °C. Water condensation on the radiator • While cooling operation, cold water may not flow to the radiator. If cold water enters to the radiator, dew generation on the surface of the radiator can be occurred. • Function Code 13 : Setting Air Temperature in Heating Mode Determine heating setting temperature range when air temperature is selected as setting temperature. Only available when remote air temperature sensor is connected • Accessory PQRSTA0 should be installed. • Also, Function Code 03 should be set properly. • Function Code 14 : Setting Leaving Water Temperature in Heating Mode Determine heating setting temperature range when leaving water temperature is selected as setting temperature. • Function Code 15 : Setting Sanitary Tank Leaving Water Temperature Determine heating setting temperature range of water tank leaving water. Only available when sanitary water tank feature is installed • Sanitary water tank and sanitary water tank kit should be installed. • DIP switch No. 2 and 3 should be set properly. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 22 - LGE Internal Use Only Features Temperature Control Parameter Setting and Etc • Function Code 21 : Setting Electric Heater On/Off temperature Using Half capacity of electric heater : when DIP Switch No. 6 and 7 is set as ʻOFF-ONʼ : - Value #1 : outdoor air temperature where half capacity of electric heater starts operation. - Value #2 : not used. - Example : If Value #1 is set as ʻ-1ʼ and DIP Switch No 6. and 7 is set as ʻOFF-ONʼ, then half capacity of electric heater will start operation when outdoor air temperature is below -1°… and current leaving water temperature or room air temperature is much belower than target leaving water temperature or target room air temperature. Using Full capacity of electric heater : when DIP Switch No. 6 and 7 is set as ʻOFF-OFFʼ : - Value #1 : base outdoor air temperature. - Value #2 : not used. - Example : If Value #1 is set as '-1' and DIP Switch No 6. and 7 is set as 'OFF-OFF', then full capacity of electric heater will start operation when outdoor air temperature is below -1°C and current leaving water temperature or room air temperature is much belower than target leaving water temperature or target room air temperature. • Function Code 22 : Setting Cut-off Temperature in Cooling Mode (FCU setting included) Determine leaving water temperature when the product is turned off. This function is used fr preventing condensation on the floor in cooling mode. - Value #1 : cut-off temperature. Value #1 is valid when Value #2 is ʼ01 (that means, FCU is installed)ʼ. - Value #2 : determines if FCU is installed or not. ʼ01ʼ means ʻFCU is NOT installedʼ, and ʼ00ʼ means ʻFCU is installed.ʼ - Example : If Value #1 is set as ʻ10ʼ and Value #2 is ʼ01ʼ and actually FCU is NOT installed in the water loop, the product stop operation in cooling mode when the leaving water temperature is below 10 °C. - Example : If Value #1 is set as ʻ10ʼ and Value #2 is ʼ00ʼ and actually FCU is installed in the water loop, the Value #1 is not used and the product do NOT stop operation in cooling mode when the leaving water temperature is below 10 °…. FCU Installation • If FCU is used, related 2way valve should be installed and connected to the indoor unit PCB. • If Value #2 is set as ʼ00ʼ but FCU or 2way valve is NOT installed, the product can Be operated abnormally. Function Code 23 and 24 : Setting Weather-dependent operation Mode Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 23 - LGE Internal Use Only Features • Function Code 23, 24, and 25 : Setting Weather-dependent operation Weather-dependent operation is that the product automatically adjusts target temperature (leaving water or room air) according to the outdoor air temperature. - Value #1 and Value #2 of Function Code 23 : range of outdoor air temperature - Value #1 and Value #2 of Function Code 24 : range of auto-adjustable target room air temperature - Value #1 and Value #2 of Function Code 25 : range of auto-adjustable target leaving water temperature Note : Weather-dependent operation is applied for heating mode only. Auto-Adjustable Target Temperature Temperature profile of Weather-dependent operation Value #1 of Function Code 24 or 25 Value #2 of Function Code 24 or 25 Value #1 of Function Code 23 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 24 - Value #2 of Function Code 23 Outdoor air temperature LGE Internal Use Only Features • Function Code 26 and 27 : Setting Disinfection operation Disinfection operation is special sanitary tank operation mode to kill and to prevent growth of viruses inside the tank. - Value #1 of Function Code 26 : Selecting enable or disable of disinfection operation. ʼ00ʼ for disable, and ʼ01ʼ for enable. - Value #2 of Function Code 26 : Determining the date when the disinfection mode is running. ʼ01ʼ for Sunday, ʼ02ʼ for Monday, … , and ʼ06ʼ for Saturday. - Value #3 of Function Code 26 : Determining the time when the disinfection mode is running. ʼ00ʼ for 0:00am, ʼ01ʼ for 01:00am, … , ʼ22ʼ for 10:00pm, and ʼ23ʼ for 11:00pm. - Sunday, ʼ02ʼ for Monday, … , and ʼ06ʼ for Saturday. - Value #1 of Function Code 27 : Target temperature of disinfection mode. - Value #2 of Function Code 27 : Duration of disinfection mode. Temperature profile of Disinfection operation Water temperature (Inside sanitary water tank) Value #1 of Function Code 27 Value #2 of Function Code 27 Value #2 of Function Code 26 Time Vales of Function Code 26 • If Value #1 of Function Code 26 is set as ʼ00ʼ, that is ʻdisable disinfection modeʼ, Value #2 and Value #3 is not used. • When Value #1 is set as ʼ01ʼ, that is ʻenable disinfection modeʼ,ʼ Value #2 is displayed at the position of Value #1 and Value #3 is displayed at the position of Value #2. It is due to limited width of the control panel display. repeatedly View 1 Press sanitary tank heating. Button to enable Sanitary water heating should be enable • If sanitary water heating is disable, the disinfection mode will not be operated although Value #1 of Code 26 is set as ʼ01ʼ. • To use disinfection mode, sanitary water heating should be enable. <Sanitary Water Heating Disable> <Sanitary Water Heating enable> Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 25 - LGE Internal Use Only Features • Function Code 28 and 29 : Setting control parameter for Sanitary water heating operation Descriptions for each parameters are as following. - Value #1 of Function Code 28 : temperature gap from Value #2 of Function Code 28. - Value #2 of Function Code 28 : maximum temperature generated by AWHP compressor cycle. - Example : If Value #1 is set as ʻ5ʼ and Value #2 is set as ʼ48ʼ, then Session A (see the graph) will be started when the water tank temperature is below 45°…. If temperature is above 48 °…, then Session B will be started. - Value #1 of Function Code 29 : temperature gap from target sanitary water temperature. This value is required to frequent On and Off of water tank heater. - Value #2 of Function Code 29 : Determining heating demand priority between sanitary water tank heating and under floor heating. - Example : If userʼs target temperature is set as ʼ70ʼ and Value #1 is set as ʻ3ʼ, then the water tank heater will be turned off when the water temperature is above 73 °C. The water tank heater will be turned on when the water temperature is below 70 °C. - Example : If Value #2 is set as ʻ0ʼ, that means heating priority is on sanitary water heating, sanitary water is heated by AWHP compressor cycle and water heater. In this case the under floor can not be heated while sanitary water heating. On the other hand, if the Value #2 is set as ʻ1ʼ, that means heating priority is on under floor heating, sanitary tank is ONLY heated by water heater. In this case the under floor heating is not stopped while sanitary water is heated. Water temperature (Inside sanitary water tank) Water heater off temperature Value #1 of Function Code 29 Target sanitary water temperature (set by user) Value #2 of Function Code 28 Value #1 of Function Code 28 Starting temperature of sanitary water heating Session A Session C Session B Session D Time Session A : Heating by AWHP compressor cycle and water heater Session B : Heating by water heater Session C : No heating (Water heater is Off) Session D : Heating by water heater • Function Code 2A : Miscellaneous setting - Value #1 of Function Code 2A : determine electric heater and water heater on and off. - Value #2 of Function Code 2A : not used. - Example : If Value #1 is set as ʻ0ʼ, then electric heater and water heater are on and off according to control logic. If Value #1 is set as ʻ1ʼ, then electric heater is never turned on and only water heater is on and off according to control logic. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 26 - LGE Internal Use Only Test Run 3. Test Run 1. Check before Test Run 1 Check to see whether there is any refrigerant leakage, and check whether the power or transmission cable is connected properly. Check liquid pipe and gas pipe valves are fully opened. 2 NOTE: Be sure to tighten caps. Confirm that 500 V megger shows 2.0 MΩ or more between power supply terminal block and ground. Do not operate in the case of 2.0 MΩ or less. 3 NOTE: Never carry out mega ohm check over terminal control board. Otherwise the control board may break. Immediately after mounting the unit or after leaving it turned off for an extended length of time, the resistance of the insulation between the power supply terminal board and the ground may decrease to approx. 2.0 MΩ as a result of refrigerant accumulation in the internal compressor. If the insulation resistance is less than 2.0 MΩ, turn on the main power supply. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 27 - LGE Internal Use Only Test Run 2. Test Run Flow chart START Test operation for indoor unit Operate the unit in cooling mode. Does Test operation start? No Refer to part4, 6 Electric part Yes Is cold water discharged for more than 3 minutes ? No Yes Is there any temperature difference between intake and discharged water? Refer to part4, 5 Cycle part No Yes Is the operating current normal ? No Yes Operation mode change to Heating mode Is hot water discharged ? After Hot Start * Check the load (In/Out Temp.) * Check pipe length and amount of refrigerant * Check for abnormal sound in outdoor unit (comp.,Fan, others ) No Refer to Troubleshooting Guide Yes Normal Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 28 - LGE Internal Use Only Part 3 Replacement Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 29 - LGE Internal Use Only Replacement Procedure for Compressor 1. Replacement Procedure for Compressor 1. Remove the sound proof covering the faulty compressor, and disconnect the power 2. Disconnect the brazing sections of suction pipe and discharge pipe by using brazing torch after the refrigerant has been pumped out or collected completely. 3. Remove three nuts at cushion rubber section to take out the faulty compressor outside the unit. <Figure 1> 4. Install the new compressor in the unit.(Be sure to insert the cushion rubbers before tightening the fixing nut of compressor.) 5. Remove the rubber caps put on the suction and discharge pipe of the new compressor to release the sealing nitrogen gas. < Figure 1 > 6. Braze the suction and discharge pipe with brazing torch to the compressor. 7. Conduct air tight test to check the piping system is free from leakage. 8. Connect power cable to the terminal board of compressor and cover the compressor with sound proof. <Figure 2> 9. Conduct vacuum. 10. After completion of vacuum, open the service valves. If recovery unit is used, charge refrigerant. When inserting the sound proof, be sure to insert counter-clockwise. < Figure 2 > Discharge pipe Suction pipe Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 30 - LGE Internal Use Only Caution for Assembling Outdoor Panels after Test Run 2. Caution for Assembling Outdoor Panels after Test Run When assemble the outdoor panels after replacement, make sure that screws of top panel are assembled as shown figure below. If screws are not assembled, it allows rain come into control box causing defect of unit. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 31 - LGE Internal Use Only Part 4 Trouble Shooting Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 32 - LGE Internal Use Only Trouble Shooting 1. Checking Key Components of Indoor Unit .....................................34 1.1 Flow Switch ...............................................................................................34 1.2 Water Pump ...............................................................................................35 1.3 Electric Heater...........................................................................................36 1.4 Control Panel ............................................................................................37 2. Checking Key Components of Outdoor Unit ..................................38 2.1 Compressor...............................................................................................38 2.2 Fan Motor ..................................................................................................39 2.3 Electronic Expansion Valve .....................................................................40 3. Self-Diagnosis Feature......................................................................43 3.1 Concept of ʻClassified Troubleʼ ...............................................................43 3.2 Error Code List..........................................................................................44 4. Trouble Shooting Guide ....................................................................46 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 33 - LGE Internal Use Only Checking Key Components of Indoor Unit 1. Checking Key Components of Indoor Unit 1.1 Flow Switch Start (*) System stopped while operation NO Water pump running YES NO NO Control Panel Shows ‘� CH14’� YES YES NO Pressure gage indicates 1.5~2.0 bar YES Water is not enough or there can be water leakage inside water circuit. The flow switch is electrically closed. A B (*) Water pump still running NO NO Control Panel Shows ‘� CH14’� YES The flow switch is electrically open. END (it is normal condition) YES The water pump is in trouble. C D (*): How to identify? - Touch the terminal box (black plastic box at the water pump) of water pump and feel if the water pump is vibrating. If no vibration, the water pump is not operating. Also, you can see ʻWater Pump Operating Icon( ) ʼ at control panel. A • Although there is not water flow inside water circuit, the flow switch detects as if water is flowing. It is due to electrically closed (or short) of flow switch or the contact of flow switch is mechanically stuck. • Contact official After Service Center and replace the flow switch. B • Check if water inside water circuit is fully charged. Pressure gage at the indoor unit should indicate 1.5~2.0 bar. • Also, as the hand of the pressure gage is not react so fast according to water charging, check the pressure gage again. • Otherwise, there can be water leakage inside water circuit. Examine if water circuit is completely sealed. C • Although water is well flowing, the flow switch can not detect water flow. It is due to electrically) open of flow switch or the contact of flow switch is mechanically broken. • Contact official After Service Center and replace the flow switch. D • Read ʻChecking Key Components of Indoor Unit – Water Pumpʼ carefully to get more detail information. • Contact official After Service Center and replace the water pump. • Also, check the water quality if there are particles that can yield locking at the shaft of the water pump. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 34 - LGE Internal Use Only Checking Key Components of Indoor Unit 1.2 Water Pump Start NO (*) Water pump always running while system operation NO Water pump runs and stops while compressor start-up YES Heating Operation NO Water pump always stop while system operation YES YES END (it is normal condition) NO Water pump does not working YES A DIP Switch No.5 is set to OFF ? NO YES Water pump control by Indoor unit PCB is not correct B (*): It is normal condition that water pump runs or stops during system operation (including compressor start-up) due to specific control logic. • Water pump does not because of mechanical defects of water pump or wrong wiring at the water pump. • To correct mechanical defects, contact official After Service Center and replace the water pump. A • To correct wrong wiring, check if wires ʻCN_W/PUMP(A)ʼ connector on the indoor unit PCB and water pump terminal box (black plastic box at the water pump) are connected firmly. Also, check wires are electrically connected by measuring resistance of each wires(if electrically connected exactly, resistance should be 0 ohm). • Indoor unit PCB can not make control signal or wrong wiring at the water pump. • To correct Indoor unit PCBʼs making control signal, first check the signal level. Use electric voltage meter and measure voltage at ʻCN_W/PUMP(A)ʼ connector on the indoor unit PCB. If measured B value is not 220V ~ 240V AC while ʻWater Pump Operating Icon( ) ʼ is displayed at control panel, the indoor unit PCB is in trouble. In this case, contact official After Service Center and replace the indoor unit PCB. • To correct wrong wiring, please refer Ⓐ. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 35 - LGE Internal Use Only Checking Key Components of Indoor Unit 1.3 Electric Heater Start (*1) Electric heater is working NO YES More than 5 minutes elapsed since electric heater working NO Electric heater working time is not enough A Electric power is not supplied B Thermodisk is not correctly working C ELB (or MCCB) cuts off Power or ELB (or MCCB) trouble D YES (*2) External electric power supply OK? NO YES (*3) Thermodisk OK? NO YES (*4) NO ELB or MCCB OK? YES (*5) Relay Contactor OK? YES NO Relay contactor is not working correctly E Electric heater is not normal F A B C D E F (*1): When electric heater is working, ʻElectric Heater Operating Icon( or ) ʼ is displayed at control panel (*2) : For single-phase model : Measure electric voltage at port 3(Live) and port 4(Neutral) of Terminal Block 3 with voltage meter. The measured value should be 220V~240V AC. To identify the location of Terminal Block 3, please refer circuit diagram of indoor unit at ʻInstallation Manualʼ or backside of front cover of the indoor unit. (*2) : For three-phase model : Measure electric voltage at two port of 3(R), 4(S), and 5(T) of Terminal Block 3 with voltage meter. The measured value should be 220V~240V AC or 380V~415V AC. To identify the location of Terminal Block 3, please refer circuit diagram of indoor unit at ʻInstallation Manualʼ or backside of front cover of the indoor unit. (*3) : For single-phase model : Find cover of thermodisk which is located beside air vent. Air vent is on the top of the electric heater tank. Uncover the cover by unscrewing bolts. Find two copper leads located both left and right side of the thermodisk core. Check resistance of both leads. The measured resistance should be 0 ohm. After then, check if voltage is transmitted to the thermodisk correctly. Measure electric voltage between one of the lead (Live) of the thermodisk and port 3(Neutral) of ELB(A). The measured value should be 220V~240V AC. (*3) : For three-phase model : Find cover of thermodisk which is located side of electric heater tank.Uncover the cover by unscrewing bolts. Find two copper leads located both left and right side of two thermodisk core. Check resistance of both leads of each thermodisks. The measured resistance should be 0 ohm. While uncovering the cover of the thermodisk, be careful for electric shock. (*4): For single-phase model : Resistance between port 1 and port 2 should be 0 ohm. Also, port 3 and port 4 should be 0 ohm, too. Finally, measure electric voltage at port 2(Live) and port 4(Neutral) with voltage meter. The measured value should be 220V~240V AC. (*4) : For three-phase model : Resistance between port 1-to-port 2, port 3-to-port 4, and port 5-to-port 6 of MCCB(A) should be 0 ohm. Port number and location of MCCB(A) can be found circuit diagram of the indoor unit(back side of front cover). (*5): For single-phase model : At Relay Contactor (A), measure electric voltage at port 2(Live) and port 6(Neutral) with voltage meter. The measured value should be 220V~240V AC. Also, at Relay Contactor (B), measure electric voltage at port 2(Live) and port 6(Neutral) with voltage meter. The measured value should be 220V~240V AC. (*5): For three-phase model : At Magnet Contact (C) or Magnet Contact (B), resistance between port L1-to-port T1, port L2-to-port T2, and port L3-to-port T3 should be 0 ohm. • Wait for 5 minutes to heat water inside electric heater tank. If capacity of electric heater is 6kW, at least 2 centigrade will be increased. • For single-phase model : Check if external electricity power supply is breakout. If not, check wiring between external electricity power supply and port 3 and port 4 of Terminal Block 3. You can identify the location of Terminal Block 3 at the circuit diagram of indoor unit. • For three-phase model : Check if external electricity power supply is breakout. If not, check wiring between external electricity power supply and port 3, port 4, and port 5 of Terminal Block 3. You can identify the location of Terminal Block 3 at the circuit diagram of indoor unit. • Thermodisk is mechanically defected. In this case, contact official After Service Center and replace the thermodisk. • Check the insulation resistance of Electric Heater. • If the insulation resistance has improper, remove the cause of the problem and then reset the ELB(or MCCB). • Replace the ELB(or MCCB) when insulation resistance is OK. • Relay contactor is is mechanically defected. In this case, contact official After Service Center and replace the relay contactor. • Heating coil of electric heater can be damaged or wiring inside the electric heater is problem. Before replacing the electric heater, in this case, contact official After Service Center and do diagnosis about electric heater and related parts including the capacity of external electric power source. If the reason of malfunction is clearly proved as the defect of the electric heater itself, then replace it with new one. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 36 - LGE Internal Use Only Checking Key Components of Indoor Unit 1.4 Control Panel To solve various troubles while using control panel, please read following FAQ (Frequently Asked Questions). For your convenience, all questions are classified according to topics. No Topic Question Answer 1 Power button does not bright System installation is finished. Also, all wirings including power connection is all right. But when the power button in front of the control panel is pushed, it does not bright. • There can be a problem in wiring between PCB and control panel. Open control box and find ʻCN_REMOʼ connector at the PCB. If the connector is empty or nothing is connected, please connect it with end of wire which is from control panel then restart the system. • Check if external controller is connected like thermostat. If thermostat is connected to the system and it is configured exactly, you can see ʻThermostat Icon ( )ʼ at the display of the control panel. It is normal condition that power button of control panel does not work when thermostat is installed. 2 Some icons are displayed automatically Although nobody touched control panel, someties it displays specific icons and the system operates automatically. • It is normal condition. Basically, two features can be operated without userʼs decision – one is system protective operation, the other is ʻbackground water tank heating operationʼ, which is heating inside the water tank while space heating is not used or the system is not working. System protective operation is, as letter says, for the purpose of securing the system from worse condition. Anti-freezing operation, for example, is one of the protective operation. It is essential to start protective operation to prevent potential malfunction and to keep possible accidents. On the other hand, background water tank heating operation is not protective operation but to supply warm water to end-user. The background water tank heating operation is only started when the water tank temperature is under the specific temperature. 3 Water tank heating or related features are not permitted Setting water tank temperature is not permitted although the water tank is installed. Following two conditions should be satisfied. • Check if ʻWater tank enable/disableʼ button is correctly pushed or not. To use water tank, end-user must push button and highlight icon. Otherwise, water tank heating is disabled. • Also, check if DIP switch setting is correct or not. To identify the DIP switch setting, open the control box inside the indoor unit. Unless 2nd and 3rd pin of DIP switch setting is 01(OFF-ON) or 10(ON-OFF), the water tank heating will not be configured. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 37 - LGE Internal Use Only Checking Key Components of Outdoor Unit 2. Checking Key Components of Outdoor Unit 2.1 Compressor Check and ensure in following order when error related with the compressor or error related with power occurs during operation: No. 1 2 Checking Item Is how long power on during operation? Does failure appears again when starting operation? Symptom Countermeasure 1) Power on for 12 hours or more • Go to No.2. 2) Power on for 12 hours or less • Go to No.2 after applying power for designated time (12 hours). • Check IPM may fail. 1) The compressor stops andsame error appears again. Method to measure insulation 2) If output voltage of the inverter is resistance stably output. Ω� • Check coil resistor and insulation resistor. If normal, restart the unit. If same symptom occurs, replace the compressor. • Insulation resistor: 2MΩ or more • Coil resistor: at 25°C Inverter (GJT240DAA) Method to measure coil resistance Ω� 3) If output voltage of the inverter is unstable or it is 0V. (When incapable of using a digital tester) U-V 0.997 U-W 0.980 V-W 0.965 • Check the IPM. If the IPM is normal, replace the inverter board. • Check coil resistor and insulation resistor. [Cautions when measuring voltage and current of inverter power circuit] Measuring values may be different depending on measuring tools and measuring circuits since voltage, current in the power supply or output side of the inverter has no same waveform. Especially, output voltage changes when output voltage of the inverter has a pattern of pulse wave. In addition, measuring values appear largely different depending on measuring tools. Note 1) If using a portable tester when checking the output voltage of the inverter is constant (when comparing relative voltage between lines), always use an analog tester. Especially exercise particular caution if the output frequency of the inverter is low, when using a movable tester, where change of measured voltage values is large between other lines, when virtually same values appear actually or where there is danger to determine that failure of the inverter occurred. 2) You can use rectification voltmeter ( ) if using commercial frequency tester when measuring output values of the inverter (when measuring absolute values). Accurate measuring values cannot be obtained with a general portaable tester (For analog and digital mode). Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 38 - LGE Internal Use Only Checking Key Components of Outdoor Unit 2.2 Fan Motor Checking Item (1) The fan motor does not operate. Does failure appears again when starting operation? Symptom Countermeasure 1) When power supply is abnormal 2) For wrong wiring (2) Vibration of the fan motor is large. • Modify connection status in front of or at the rear of the breaker, or if the power terminal console is at frosting condition. • Modify the power supply voltage is beyond specified scope. • For following wiring. 1. Check connection status. 2. Check contact of the connector. 3. Check that parts are firmly secured by tightening screws. 4. Check connection of polarity. 5. Check short circuit and grounding. 3) For failure of motor • Measure winding resistance of the motor coils. 4) For failure of circuit board Replace the circuit board in following procedures if problems occur again when powering on and if there are no matters equivalent to items as specified in above 1) through 4). (Carefully check both connector and grounding wires when replacing the circuit board.) 1. Replace only fan control boards. If starting is done, it means that the fan control board has defect. 2. Replace both fan control board and the main board. If starting is done, it means that the main board has defect. 3. If problems continue to occur even after countermeasure of No.1 and No.2, it means that both boards has defect. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 39 - LGE Internal Use Only Checking Key Components of Outdoor Unit 2.3 Electronic Expansion Valve DC 12V Driving� circuit EEV ø5 Red 5 ø4 White 4 ø4 2 ø3 Yellow 3 ø3 3 ø2 Orange 2 ø2 ø1 Blue 1 ø1 4 6 M 1 • Pulse signal output value and valve operation Output(ø) No. Output state 1 2 3 4 5 6 7 8 ø1 ON OFF OFF OFF OFF OFF ON ON ø2 ON ON ON OFF OFF OFF OFF OFF ø3 OFF OFF ON ON ON OFF OFF OFF ø4 OFF OFF OFF OFF ON ON ON OFF • Output pulse sequence - In valve close state: 1 → 2 → 3 → 4 → 5 → 6 → 7 → 8 → 1 - In valve open state: 8 → 7 → 6 → 5 → 4 → 3 → 2 → 1 → 8 1. If EEV open angle does not change, all of output phase will be OFF 2. If output phase is different or continuously in the ON state, motor will not operate smoothly and start vibrating. • EEV valve operation Valve� open� Angle - At power ON, open angle signal of 1400 pulses output and valve position is set to ⓐ If valve operates smoothly, no noise and vibration occur and if valve is closed. noise occurs. close Full open� 1350 pulses open - Noise from EEV can be confirmed by touching the EEV surface with a screw driver and listening the EEV noise. - If liquid refrigerant is in EEV, the noise is lower. pulse Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 40 - LGE Internal Use Only Checking Key Components of Outdoor Unit • EEV Coil and body(Outdoor unit) Coil part Body Lead wire • Remove and assemble the coil Remove Assemble • Grip the A part tightly, and pull up coil part upward. When the coil part is removed or assembled, be careful not to bend the pipe of the body. A part Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 41 - LGE Internal Use Only Checking Key Components of Outdoor Unit •�EEV failure check method Failure mode Microcomputer Driving circuit failure Diagnosis 1.Disconnect the EEV connector form control board and connect testing LED 1K� Repair process Unit Check and replace Indoor unit control board Indoor unit LED 2. Main power ON, pulse signal is out from EEV for 17 sec. If LEDs do not turn on, or are in on state continuously, then driving circuit is abnormal EEV locking 1.If EEV is locked, in no load state, the driving motor rotate, and clicking sound always occurs Replace EEV Indoor / Outdoor unit EEV Motor coil short or misconnection 1. Check the resistance between coil terminal (red-white, red-yellow, red-orange, red-blue) 2. If the estimated resistance value is in 52 ± 3Ω� then the EEV is normal 1. Check the resistance between coil terminal (brown-white, brown-yellow, brown-orange, brown-blue) 2. If the estimated resistance value is in 150 ± 10Ω� then the EEV is normal Replace EEV Outdoor unit Replace EEV Indoor unit Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 42 - LGE Internal Use Only Self-Diagnosis Feature 3. Self-Diagnosis Feature 3.1 Concept of ʻClassified Troubleʼ • Definition of terms - Trouble : a problem which can stop system operation, and can be resumed temporarily under limited operation without certificated professionalʼs assist. - Error : a problem which can stop system operation, and can be resumed ONLY after certificated professionalʼs check. - Emergency mode : temporary heating operation while system met Trouble • Objective of introducing ʻTroubleʼ - Not like airconditioning product, Air-to-Water heat pump is generally operating in whole winter season without any system stopping. - If system found some problem, which is not critical to system operating for yielding heating energy, the system can temporarily continue operating in emergency mode with enduserʼs decision. • Classified Trouble - Trouble is classified two levels according to the seriousness of the problem : Slight Trouble and Heavy Trouble - Slight Trouble : a problem is found inside the indoor unit. In most case, this trouble is concerned with sensor problems. The outdoor unit is operating under emergency mode operation condition which is configured by DIP switch No. 4 of the indoor unit PCB. - Heavy Trouble : a problem is found inside the outdoor unit. As the outdoor unit has problem, the emergency mode operation is performed by electric heater located in the indoor unit. - Option Trouble : a problem is found for option operation such as water tank heating. In this trouble, the troubled option is assumed as if it is not installed at the system. • Emergency operation is not automatically restarted after main electricity power is reset. - In normal condition, the product operating information is restored and automatically restarted after main electricity power is reset. - But in emergency operation, automatic re-start is prohibited to protect the product. - Therefore, user must restart the product after power reset when emergency operation has been running. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 43 - LGE Internal Use Only Self-Diagnosis Feature 3.2 Error Code List Code No. Classification Description Slight Heavy Option Trouble Trouble Trouble O Unit Error 01 Problem in Remote Room Air sensor Indoor 02 Problem in Refrigerant (Inlet side) sensor 03 Bad communication between control panel and indoor unit O Indoor 05 Bad communication between Indoor unit and Outdoor unit O Indoor / Outdoor 06 Problem in Refrigerant (Outlet side) sensor 08 Problem in Water Tank sensor 09 PCB Program (EEPROM) Fault 13 Problem in Solar-thermal sensor 14 Problem in Flow Switch O Indoor 15 Water pipe overheated O Indoor 16 Problems in sensors O Indoor 17 Problem in Water-inlet sensor O Indoor 18 Problem in Water-outlet sensor O Indoor 19 Problem in Water-interlim sensor O Indoor 20 Electric heater overheated O Indoor O Indoor O Water Tank O O Indoor Indoor O Indoor • Notice of error code - Slight / Heavy / Option Troubles : lowercases ʻchʼ + code no. - Errors : capital letters ʻCHʼ + code no. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 44 - LGE Internal Use Only Self-Diagnosis Feature Classification Code No. Description Slight Heavy Option Error Trouble Trouble Trouble LED Blinking Unit LED1 (Red) LED2 Green) 21 DC Peak (IPM Fault) O Outdoor 1 time 22 CT 2 (Max CT) O Outdoor 2 times 23 DC Link Voltage is low O Outdoor 3 times 24 High Pressure / Low Pressure switch activated O Outdoor 4 times 25 Voltage is too low or too high O Outdoor 26 Problem in DC Compressor positioning O Outdoor 6 times 27 PSC Fault O Outdoor 7 times 28 DC Link Voltage is high O Outdoor 8 times 29 High current at Compressor phases O Outdoor 9 times 32 Temperature at discharge-pipe is too high O Outdoor 40 Problem in CT sensor O Outdoor none 41 Problem in discharge-pipe temperature sensor O Outdoor 1 time 44 Problem in ambient temperature sensor O Outdoor 45 Problem in condenser-pipe temperature sensor O Outdoor 5 times 46 Problem in suction-pipe temperature sensor O Outdoor 6 times 52 Bad communication between internal PCBs O Outdoor 2 times 3 times 4 times 5 times 5 times 2 times 4 times 2 times 53 Bad communication between Indoor unit and Outdoor unit O Outdoor 3 times 60 EEPROM Checksum mismatched O Outdoor none 61 Temperature at condenser-pipe is too high O Outdoor 1 time 62 Temperature at heatsink is too high O Outdoor 63 Temperature at condenser-pipe is too low O Outdoor 65 Problem in heatsink temperature sensor O Outdoor 73 Instant over current input O Outdoor 6 times 2 times 3 times 5 times 6 times 3 times Error Indicator (Outdoor PCB) Outdoor Error Ex) Error 21 (DC Peack) 2 Times 2 Times 2 Times LED01G� (RED) 1 Sec. 1 Sec. 1 Time 1 Sec. 1 Time 1 Time LED02G� (GREEN) 2 Sec. 2 Sec. CAUTION Precaution in Service or Check Even after stopping the operation of product, it takes some time to discharge the remaining electricity of the electrolytic capacitor that was charged early. Before conducting a checking or repairing job, pull out the plug out of the outlet and make sure that the lamp on the control board outdoor unit is off. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 45 - LGE Internal Use Only Trouble Shooting Guide 4. Trouble Shooting Guide Display code Description Cause Normal Condition 01 Problem in Remote Room Air sensor 02 Problem in Refrigerant (Inlet side) sensor 06 Problem in Refrigerant (Outlet side) sensor 08 Problem in Water Tank sensor 13 Problem in Solar-thermal sensor 16 Problems in sensors • PCB fault 17 Problem in Water-inlet sensor • Sensor fault • Voltage: 2.5Vdc at 25 centigrade (plugged) (for all sensors) 18 Problem in Water-outlet sensor 19 Problem in Water-interlim sensor • Incorrect connection between sensor and PCB • Resistance: 10k ohm at 25 centigrade (unplugged) → for Remote Room Air sensor • Resistance: 5k ohm at 25 centigrade (unplugged) → for all sensors EXCEPT Remote Room Air sensor • Refer resistance-temperature table to check in different temperature Check Flow Chart Is sensor properly connected to PCB? No Connect properly to PCB Yes Is the resistance value of sensor normal? No Change the sensor Yes Change the PCB Unplugged� � Plugged� � 10kΩ� 2.5Vdc Ω� V Check the resistance Check the voltage� � Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 46 - LGE Internal Use Only Trouble Shooting Guide Display code 03 Description Cause Bad communication between control panel and indoor unit. Normal Condition • Incorrect connection between sensor and PCB • Wire connection between control panel and indoor unit PCB should be tight • PCB fault • Output voltage of PCB should be 12Vdc • Sensor fault Check Flow Chart Does the error occur again when the control panel is replaced? No Indoor Unit Replace the control panel 12V� S� GND� (RD)�(YL)�(BK)� � � � Yes Does the error occur again when the cable (between control panel and PCB) is replaced? No Check if the wire is connected tightly and also check wire itself 12Vdc Yes V Replace indoor unit PCB Check the Voltage. After replacing the control panel or indoor unit PCB, it is very important to perform parameter setting by ʻentering Installer Setting Modeʼ at the control panel. If not, system will NOT be operated correctly. It is STRONGLY recommended to keep above instruction. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 47 - LGE Internal Use Only Trouble Shooting Guide Display code 05 Description Cause Normal Condition • The connector for transmission is disBad communication connected between Indoor unit • The connecting wires are misconand Outdoor unit • Wire connection between control panel nected and indoor unit PCB should be tight • The communication line is broken • Outdoor PCB is abnormal 53 • Indoor PCB is abnormal Check Flow Chart Replace indoor unit PCB Control panel displays CH05? No Reconnect transmission cable between indoor unit PCB and control panel Yes Is outdoor PCB LED blinking? No Check the main power supply at the ODU terminal block? No Replace outdoor PCB after checking Replace TRANS after checking Yes Yes No Is main circuit breaker off? Yes Check the insulation of inverter Check the capacity of main circuit breaker and replace if required Improper connection of power supply cable Main power supply problem Check if the transmission cable is properly connected to indoor / outdoor terminal block?* Yes No If all ok, Turn on main circuit breaker Re-connect transmission cable Outdoor PCB fault Replace after checking Indoor PCB fault Replace after checking Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 48 - � ❊ CH05 is displayed at indoor unit, � CH53 is displayed at outdoor unit.� � LGE Internal Use Only Trouble Shooting Guide Display code 09 Description PCB Program (EEPROM) Fault Cause • Electrical or mechanical damage a the EEPROM Normal Condition • This error can not be permitted Check Flow Chart - Replace the indoor unit PCB Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 49 - LGE Internal Use Only Trouble Shooting Display code Description Cause Normal Condition • Flow switch is open while • Flow switch should be closed while interinternal water pump is working nal water pump is working or DIP switch • Flow switch is closed while inter- No. 5 of indoor unit PCB is set as ON 14 Problem in Flow Switch nal water pump is not working • Flow switch is open while DIP switch No. 5 of indoor unit PCB is set as ON • Flow switch should be open while internal water pump is not working Check Flow Chart Start (*) System stopped while operation NO Water pump running YES NO Control Panel Shows ‘CH14’ YES NO Pressure gage indicates 1.5~2.0 bar YES NO YES Water is not enough or there can be water leakage inside water circuit. The flow switch is electrically closed. A B (*) Water pump still running NO Control Panel Shows ‘CH14’ YES The flow switch is electrically open. C END (it is normal condition) NO YES The water pump is in trouble. D (*): How to identify? - Touch the terminal box (black plastic box at the water pump) of water pump and feel if the water pump is vibrating. If no vibration, the water pump is not operating. Also, you can see ʻWater Pump Operating Icon( ) ʼ at control panel. A • Although there is not water flow inside water circuit, the flow switch detects as if water is flowing. It is due to electrically closed (or short) of flow switch or the contact of flow switch is mechanically stuck. • Contact official After Service Center and replace the flow switch. B • Check if water inside water circuit is fully charged. Pressure gage at the indoor unit should indicate 1.5~2.0 bar. • Also, as the hand of the pressure gage is not react so fast according to water charging, check the pressure gage again. • Otherwise, there can be water leakage inside water circuit. Examine if water circuit is completely sealed. C • Although water is well flowing, the flow switch can not detect water flow. It is due to electrically) open of flow switch or the contact of flow switch is mechanically broken. • Contact official After Service Center and replace the flow switch. D • Read ʻChecking Key Components of Indoor Unit – Water Pumpʼ carefully to get more detail information. • Contact official After Service Center and replace the water pump. • Also, check the water quality if there are particles that can yield locking at the shaft of the water pump. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 50 - LGE Internal Use Only Trouble Shooting Display code Description Cause Normal Condition • If there is no problem in electric heater control, possible maximum leaving • Leaving water temperature water temperature is 55°C. is above 72°C • Abnormal operation of electric heater 15 Water pipe overheated Check Flow Chart Start Leaving water temperature is higher than target YES water temperature END (it is normal condition) NO YES A Thermostat is installed NO A • This is unexpected case. • Turn off the system and call service center. • If the system is not turned off before it yields error code (CH15), very hot leaving water will be generated and it is harmful to human. YES Leaving water temperature is higher than 62 °C B NO B • Room air is not fully heated by under floor heating. • Wait while room air is heated by target temperature of thermostat. YES Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 51 - LGE Internal Use Only Trouble Shooting Display code Description Cause Normal Condition • If there is no problem in electric heater control, possible maximum leaving • Leaving water temperature water temperature is 55°C. is above 90°C • Abnormal operation of electric heater 20 Electric Heater Overheated Check Flow Chart Start Leaving water temperature is higher than target YES water temperature END (it is normal condition) NO YES A Thermostat is installed NO A YES Leaving water temperature is higher than 90 °C NO • This is unexpected case. • Turn off the system and call service center. • If the system is not turned off before it yields error code (CH20), very hot leaving water will be generated and it is harmful to human. • If Error Code (CH20) is occurred, please check thermostat, electric heater, power supply and others. Also, it is recommended to check air vent which is located on the top of the electric heater tank. B YES Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes B • Room air is not fully heated by under floor heating. • Wait while room air is heated by target temperature of thermostat. - 52 - LGE Internal Use Only Trouble Shooting Display code Title 21 DC Peak Cause of error • Instant over current • Over Rated current • Poor insulation of IPM Check point & Normal condition • An instant over current in the U,V,W phase - Comp lock - The abnormal connection of U,V,W • Over load condition - Overcharging of refrigerant - Pipe length. • Poor insulation of compressor Check Flow Chart Check the wire connection.(U,V,W) Is it normal ? Yes Is it normal ? (1 Ph : 230V 10% 3 Ph : 400V 10% ) Yes No Correct connection Check DC link capacitor Is it normal? (Refer to belows) Check the resistance of comp. (No difference at each terminal) Is it normal ? Yes Yes Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked No Change Compressor Check the electricity leakageof the compressor. (Refer to comp check table) Is it normal ? Yes No Needs electric work No Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant No Change Main PCB No Change Compressor ❊ Dc link voltage table Model 1 Phase Check the input power (Outdoor, Indoor unit) 3 Phase Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes DC Link Voltage Type Non operating DC300V Ź 10% DC300V Ź 10% DC300V Ź 10% DC300V Ź 10% DC300V Ź 10% DC300V Ź 10% DC300V Ź 10% Operating DC280V Ź 10% DC280V Ź 10% DC380V Ź 10% DC380V Ź 10% DC380V Ź 10% DC380V Ź 10% DC380V Ź 10% AUUW126C AUUW186C AUUW246D AUUW306D AUUW366D AUUW426D AUUW486D PSC PSC PFC PFC PFC PFC PFC AUUW606D PFC DC300V Ź 10% DC380V Ź 10% AUUW368D AUUW428D AUUW488D PSC PFC PFC DC540V Ź 10% DC540V Ź 10% DC540V Ź 10% DC500V Ź 10% DC680V Ź 10% DC680V Ź 10% AUUW608D PFC DC540V Ź 10% DC680V Ź 10% - 53 - LGE Internal Use Only Trouble Shooting Display code 22 Title Max. C/T Cause of error Check point & Normal condition • Malfunction of compressor • Blocking of pipe • Low voltage input • Refrigerant, pipe length, blocked, … • Over current Check Flow Chart Check the wire connection.(U,V,W) Is it normal ? Yes Is it normal ? (1 Ph : 230V 10% 3 Ph : 400V 10% ) No Correct connection Check the resistance of comp. (No difference at each terminal) Is it normal ? Yes Check the electricity leakageof the compressor. (Refer to comp check table) Is it normal ? Yes Yes Check DC link capacitor Is it normal? (Refer to belows) Yes No Change Compressor No Needs electric work Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked No Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant No Change Main PCB No Change Compressor Check the input power (Outdoor, Indoor unit) Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 54 - LGE Internal Use Only Trouble Shooting Display code Title 23 DC Link Low voltage. • 1ph : DC link volt. is 140Vdc . • 3ph : DC link volt. is 250Vdc . • Check the power source. • Check the components. DC Link High voltage • 1ph : DC link volt. is 140Vdc . • 3ph : DC link volt. is 250Vdc . • Check the power source. • Check the components. Cause of error Check point & Normal condition ’ ’ ’ ’ 28 ❊ Check DC link voltage Check Flow Chart Check the wire connection.(U,V,W) Is it normal ? Yes Is it normal ? Yes Is it normal ? Yes No Correct connection V No Change Compressor No Change Compressor Check the input power ❊ Dc link voltage table Model 1 Phase Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes AHUW096A1 - 55 - DC Link Voltage Type PFC Non operating DC310V Ź 10% Operating DC380V Ź 10% LGE Internal Use Only Trouble Shooting Display code Title 24 Press S/W Open Cause of error • High pressure S/W open. Check point & Normal condition • Check the connection of “CN_PRESS” • Check the SVC V/V open. • Check the leakage of refrigerant. Check Flow Chart Is the wire connection normal ? No Correct connection Yes Is the soldering state of connector is normal? No Re-soldering component Yes Is the SVC Valve opened ? No Open SVC Valve Yes CN_PRESS Check the leakage of refrigerant. Check Pressure of suction pipe Check Pressure of discharge pipe Is it normal ? Yes No Re-vaccuming system & Re-charging Change main PCB Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 56 - LGE Internal Use Only Trouble Shooting Display code Title 26 DC Compressor Position • Compressor position detect error • Check the connection of comp wire “U,V,W” • Malfunction of compressor • Check the component of “IPM”, detection parts. 27 PSC Fault PFC Fault • Over current at “IGBT”/PFC module • Check the component of “IGBT” /PFC module. • Check the components. Cause of error Check point & Normal condition Check Flow Chart Check the wire connection.(U,V,W) Is it normal ? Yes Is it normal ? (1 Ph : 230V 10% 3 Ph : 400V 10% ) Yes No Correct connection Check DC link capacitor Is it normal? (Refer to belows) Check the resistance of comp. (No difference at each terminal) Is it normal ? Yes Yes Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked No Change Compressor Check the electricity leakageof the compressor. (Refer to comp check table) Is it normal ? Yes No Needs electric work No Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant No Change Main PCB No Change Compressor ❊ Dc link voltage table Model 1 Phase AHUW096A1 DC Link Voltage Type PFC Non operating DC310V Ź 10% Operating DC380V Ź 10% Check the input power (Outdoor, Indoor unit) Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 57 - LGE Internal Use Only Trouble Shooting Display code 29 Title Inverter compressor over current Cause of error Check point & Normal condition 1. Overload operation (Pipe clogging/Covering/EEV defect/Ref. overcharge) Inverter compressor input 2. Compressor damage(Insulation damage/Motor current is over 23A damage) 3. Input voltage low 4. ODU inverter PCB assembly damage Check Flow Chart Is installation condition normal? No Yes Are the resistance between each phase and insulation resistance of Inverter compressor normal? No 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure → Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor (0.188 ±7%) 2. Check insulation resistance between compressor terminal and pipe (over 50MΩ ) → Replace compressor if abnormality found Yes Is compressor wire connection condition normal? No 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) → Reassemble if abnormality found Yes Is input voltage normal? No Check L~N phase is 220V ±15% → Check connection condition and wiring if power is abnormal No Check inverter PCB assembly IPM normality → Replace inverter PCB assembly Yes Is inverter PCB assembly normal? Yes Recheck power and installation condition Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 58 - LGE Internal Use Only Trouble Shooting Display code Title 39 Transmission Error Between (PFC Micom ’ INV Micom) Cause of error Communication Error Between PFC Micom and INV Micom. Check point & Normal condition 1. Micom defect/Circuit defect 2. Different Micom S/W Version 3. ODU inverter PCB assembly damage Check Flow Chart Is PFC Micom & INV Micom S/W Program normal? No Upgrade Micom Program Yes Is Inverter PCB assembly normal? No Replace inverter PCB assembly Yes Recheck power and installation condition Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 59 - LGE Internal Use Only Trouble Shooting Title 32 D-pipe (Inverter) temp. high (105˚C ) 33 D-pipe (Constant) temp. high (105˚C ) ’ ’ Display code Cause of error Check point & Normal condition • Discharge sensor (Inverter) temp. high • Check the discharge pipe sensor for INV. • Check the install condition for over load. • Check the leakage of refrigerant. • Check the SVC V/V open. • Refer to sensor resistance table. • Discharge sensor (Cons.) temp. high • Check the discharge pipe sensor for Cons. • Check the install condition for over load. • Check the leakage of refrigerant. • Check the SVC V/V open. • Refer to sensor resistance table. Check Flow Chart Check Over load condition - Refrigerant leakage - Condenser is blocked - Outdoor fan is locked Yes Is the resistance of the sensor is 200kΩ at 25˚C? No Remove obstruction Change outdoor fan or motor Change refrigerant Yes Plug the sensor on Indoor unit PCB Unplug the sensor on Outdoor unit PCB Estimate the Voltage of each sensor. Check the Connector connection Is it normal ? No Change the sensor Yes Is the voltage of the sensor is 4.5Vdc at 25˚C No Correct connection Yes Yes Repair or Change the PCB. Estimate the resistance of each sensor. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes No Change the sensor - 60 - LGE Internal Use Only Trouble Shooting Display code 40 Error Type CT sensor error Error Point Main Reasons 1. Input voltage abnormal (T-N) Micom input voltage isn't within 2.5V ±0.3V at initial 2. ODU inverter PCB damage state of power supply (CT sensing part) Check Flow Chart Is input voltage normal? No Check L~N phase voltage is 220V ±10% → Check connection condition and wiring if power is abnormal Yes Is inverter PCB assembly normal? No Replace inverter PCB assembly Yes Recheck power and installation condition Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 61 - LGE Internal Use Only Trouble Shooting Display code Title 41 47 D-pipe sensor(Inv) D-pipe sensor(Cons) • Connector connection error • Normal resistor : 200KΩ/ at 25˚C (Unplugged) • Normal voltage : 4.5Vdc / at 25˚C (plugged) • Faulty PCB • Faulty sensor (Open / Short) • Refer to sensor resistance table. 44 Air sensor • Connector connection error • Normal resistor : 10KΩ/ at 25˚C (Unplugged) • Normal voltage : 2.5Vdc / at 25˚C (plugged) • Faulty PCB • Faulty sensor (Open / Short) • Refer to sensor resistance table. 45 46 Condenser Pipe sensor Suction Pipe sensor • Connector connection error • Normal resistor : 5KΩ/ at 25˚C (Unplugged) • Normal voltage : 2.5Vdc / at 25˚C (plugged) • Faulty PCB • Faulty sensor (Open / Short) • Refer to sensor resistance table. 65 Heat sink sensor • Connector connection error • Normal resistor : 5KΩ/ at 25˚C (Unplugged) • Normal voltage : 2.5Vdc / at 25˚C (plugged) • Faulty PCB • Faulty sensor (Open / Short) • Refer to sensor resistance table. Cause of error Check point & Normal condition Check Flow Chart Unplug the sensor on Indoor unit PCB Estimate the Voltage of each sensor. Check the Connector connection Is the voltage of the sensor is 4.5Vdc / 2.5Vdc at 25˚C No Change the sensor Yes Is it normal ? No Correct connection Yes Repair or Change the PCB. Unplugged Plugged Estimate the resistance of each sensor. Is the resistance of the Sensor is 200kΩ/10kΩ⁄ /5kΩ at 25˚C? No Change the sensor Yes 10kΩ 2.5Vdc Ω V Plug the sensor on Indoor unit PCB Check the resistance Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 62 - Check the voltage LGE Internal Use Only Trouble Shooting Display code Title 51 Over capacity 60 EEPROM Check sum Cause of error Check point & Normal condition • Over capacity Combination • Check the indoor unit capacity. • Check the combination table. • Check sum error • Check the connection port. • Check the poor soldering. Check Flow Chart (CH51) Check the indoor unit combination Check the outdoor unit max combination Is it normal ? No Correct connection Yes Check PCB Check Flow Chart (CH60) Check the the connection port. Is it normal ? No Correct connection Yes Change EEPROM Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 63 - LGE Internal Use Only Trouble Shooting Display code Title 61 Condenser pipe sensor temp. high • condenser pipe sensor detected high temp.(65˚C) • Check the load condition. • Check the sensor of Condenser pipe sensor. • Normal resistor : 5KΩ/ at 25˚C (Unplugged) • Normal voltage : 2.5Vdc / at 25˚C (Plugged) 62 Heat sink sensor temp. high • heat sink sensor detected high temp. (85˚C) • Check the load condition. • Check the sensor of heat sink. • Normal resistor : 10KΩ/ at 25˚C (Unplugged) • Normal voltage : 2.5Vdc / at 25˚C (Plugged) Cause of error Check point & Normal condition Check Flow Chart Check Over load condition - Refrigerant leakage - Condenser is blocked - Outdoor fan is locked Yes Is the resistance of the Sensor is 5kΩ /10kΩ at 25˚C? No Remove obstruction Change outdoor fan or motor Change refrigerant Yes Plug the sensor on Indoor unit PCB Unplug the sensor on Outdoor unit PCB Estimate the Voltage of each sensor. Check the Connector connection Is it normal ? No Change the sensor Yes Is the voltage of the sensor is 4.5Vdc / 2.5Vdc at 25˚C No Correct connection Yes Yes Repair or Change the PCB. Estimate the resistance of each sensor. Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes No Change the sensor - 64 - LGE Internal Use Only Trouble Shooting Display code 73 Title AC input instant over current error (Matter of software) Cause of error Check point & Normal condition Inverter PCB input power current is over 48A(peak) for 2ms 1. Overload operation (Pipe clogging/Covering/EEV defect/Ref.overcharge) 2. Compressor damage (Insulation damage/Motor damage) 3. Input voltage abnormal (L, N) 4. Power line assemble condition abnormal 5. Inverter PCB assembly damage (input current sensing part) Check Flow Chart Is installation condition normal? No Yes 1.Check Pipe clogging/distortion 2.Check Covering (Indoor/Outdoor Unit) 3.Check EEV connector assemble condition/normal operation 4.Check refrigerant pressure → Reassemble or manage if abnormality found No Check L~N phase voltage is 220V ±10% → Check connection condition and wiring if power is abnormal No 1.Check L, N connection condition 2.Check wire disconnection and wiring → Reassemble if abnormality found No 1.Check inverter PCB assembly U,V,W connector connection condition 2.Check wire disconnection and wiring 3.Check compressor terminal connection condition(bad contact) → Reassemble if abnormality found Is input voltage normal? Yes Is AC input Wire connection condition normal? Yes Is compressor Wire connection condition normal? Yes Is inverter PCB assembly normal? No Check inverter PCB assembly IPM normality → Replace inverter PCB assembly Yes Recheck power and installation condition Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 65 - LGE Internal Use Only Trouble Shooting Sensor resistance table Pipe Temp Air Temp B Constant 3977 B Constant 3977 Std Temp 25 Std Temp 25 Resistance 5 Resistance 10 Temp Resistance Volt Temp Resistance Volt -30 102.17 4.714 -30 204.35 4.72 -25 73.49 4.611 -25 146.97 4.62 -20 53.55 4.481 -20 107.09 4.492 -15 39.5 4.322 -15 79 4.336 -10 29.48 4.131 -10 58.95 4.149 -5 22.24 3.91 -5 44.47 3.931 0 16.95 3.661 0 33.9 3.685 5 13.05 3.389 5 26.09 3.416 10 10.14 3.102 10 20.27 3.131 15 7.94 2.808 15 15.89 2.838 20 6.28 2.515 20 12.55 2.546 25 5 2.232 25 10 2.262 30 4.01 1.965 30 8.03 1.994 35 3.24 1.717 35 6.49 1.745 40 2.64 1.493 40 5.28 1.519 45 2.16 1.293 45 4.32 1.316 50 1.78 1.116 50 3.56 1.137 55 1.48 0.962 55 2.95 0.981 60 1.23 0.828 60 2.46 0.846 65 1.03 0.714 65 2.06 0.729 70 0.87 0.615 70 1.74 0.628 75 0.74 0.531 75 1.47 0.542 80 0.63 0.459 80 1.25 0.469 85 0.54 0.397 85 1.07 0.406 90 0.46 0.345 90 0.92 0.353 95 0.4 0.3 95 0.79 0.307 100 0.34 0.262 100 0.68 0.268 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 66 - LGE Internal Use Only Trouble Shooting Heatsink Temp D-Pipe Temp B Constant 3970 B Constant 3500 Std Temp 25 Std Temp 25 Resistance 10 Resistance 200 Temp Resistance Volt Temp Resistance Volt -30 102.17 4.71 -30 2845.99 4.969 -25 73.49 4.61 0 585.66 4.851 -20 53.55 4.48 5 465.17 4.814 -15 39.5 4.32 10 372.49 4.77 -10 29.48 4.13 15 300.58 4.717 -5 22.24 3.91 20 244.33 4.657 0 16.95 3.66 25 200 4.587 5 26.05 4.73 30 164.79 4.508 10 20.25 4.66 35 136.64 4.418 15 15.87 4.57 40 113.98 4.318 20 12.55 4.47 45 95.62 4.208 25 10 4.35 50 80.65 4.088 30 8.03 4.21 55 68.38 3.958 35 6.49 4.06 60 58.27 3.82 40 5.28 3.89 65 49.88 3.674 45 4.33 3.71 70 42.9 3.522 50 3.57 3.52 75 37.05 3.365 55 2.96 3.32 80 32.14 3.205 60 2.47 3.11 85 27.99 3.043 65 2.07 2.9 90 24.46 2.88 70 1.74 2.69 95 21.46 2.719 75 1.48 2.48 100 18.89 2.561 80 1.26 2.28 110 14.79 2.255 85 1.07 2.09 120 11.72 1.972 90 0.92 1.9 130 9.4 1.716 95 0.8 1.73 140 7.62 1.487 100 0.69 1.57 150 6.24 1.287 Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 67 - LGE Internal Use Only Trouble Shooting Check of compressor n Check resistance of the compressor n Check Insulation resistance of the compressor Comp U Comp Copper pipe Ω V Ω W Model AHUW096A1 Resistance(Ω at 20℃) Resistance(Ω) at 20°C U-V U-W V-W Terminal All models 0.997 0.980 0.965 U-GND More than 2MΩ V-GND More than 2MΩ W-GND More than 2MΩ Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes - 68 - LGE Internal Use Only P/NO : MFL62748202 September , 2011